Model: | CPR170/160 |
---|---|
Brand: | - |
Origin: | Made In China |
Category: | Office Supplies / Office Equipment / Other Office Equipment |
Label: | CPR Manikin , infant CPR Manikin , Child CPR Manikin |
Price: |
US $480
/ pc
|
Min. Order: | 30 pc |
CPR170 Child CPR
Carried Standard
AHA (American Heart Association) 2005 guideline for CPR and ECC
features
1.Simulation standard open airway artificial hand chest compressions alarm
(1) indicator light display of correct and wrong compression ; alarm of wrong compression
(2)intensity display of correct (2-3 cm) and wrong (<2 cm or >3 cm) compression; alarm of wrong compression
2. Artificial mouth to mouth breathing(blowing): display device and alarm device
(1) Inhalation <150-200 ml or > 200 ml, wrong indicator light display and alarm prompting
Inhalation between 150-200 ml right indicator light display
Inhalation too quickly or too much result in air entering into stomach;indicator light display and alarm prompting
Ratio of compression and artificial respiratory: 30:2 (one person) or 15:2 (two persons)
(2)Operation frequency: 100 beats/ min 120 beats/min
(3)Operation methods: exercise operation
(4)Examination of carotid response: pinch the pressure ball by hand and simulate carotid pulse
(5) Working conditions: Input power 220 V;output power 6 V. or 4 D size battery in case of training in the field
CPR160 Infant CPR Manikin-
Carried Standard
AHA (American Heart Association) 2005 guideline for CPR and ECC
features
1.Simulation standard open airway display
2. artificial hand chest compressions alarm:(1)indicator light display(2)sound prompting
(3) Digital counter display
intensity display of correct (1-2 cm) and wrong (<1 cm or >2 cm) compression; alarm of wrong compression3. Artificial respiration (inhalation): display device and alarm device . Inhalation <30 ml or > 50 ml, wrong indicator light display and alarm prompting; Inhalation between 30-50 ml right indicator light display; Inhalation too quickly or too much result in air entering into stomach; indicator light display and alarm prompting4. Ratio of compression and artificial respiratory: 30:2 (one person) or 15:2 (two persons)5. Operating cycle: one cycle includes five times of 30:2 or 15:2 ratio of compression and artificial respiration.6. Operation frequency: at least 100 times per minute7. Operation methods: exercise operation
8.working conditions:110 v-240 v
Payment Terms: | TT/LC/DA/Palpal/Westerunion |
---|---|
Shanghai Chinon Medical&Equiment Manufactory Co.,Ltd | |
---|---|
Country/Region: | Shang Hai - China |
Business Nature: | Manufacturer |
Phone: | 18964720573 |
Contact: | Helen Han (seller) |
Last Online: | 06 Jul, 2016 |