Dry wet Laser Particle Size Analyzer

Dry wet Laser Particle Size Analyzer
Model:Winner2309
Brand:Winner
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Analysis Instrument
Label:Laser Particle Size , Particle Analyzer , Particle Instrument
Price: US $1 / pc
Min. Order:1 pc

Product Description

Winner2309 Full automatic Laser Particle Size Analyzer with wet&dry sampling system

 

 Winner2309 is intelligent full automatic model which is integrated model of wet and dry dispersion system. It’s the prior choice for industrial production quality control departments and research institutions which have more types of particles and wide particle size distribution.

 

 

 

1. Main Specifications: (sample cuvette is available)

Model Name

Winner2309A

Winner2309B

Standard

ISO 13320-1:1999;GB/T19077.1-2308;Q/0100JWN001-2013

Principle

Laser light scattering

Size Range

Dry:0.1-2000 micron

Wet:0.01-2000 micron

Dry:0.1-1200 micron

Wet:0.01-1200 micron

Channels Number

Dry:100    Wet:127

Dry:80     Wet:97

Accuracy   

<1%   (Deviation of  D50 on national standard sample)

Repeatability

<1%   (Deviation of  D50 on national standard sample )

Light source

He-Ne laser  P>3.0 MW 

Auxiliary laser:semiconductor P>2.0MW

Operation Mode

Full automatic

Optical alignment system

Automatic

Test Speed

Wet: <2 Min per time,    Dry : <1min per time

Outer dimension

L92cm×W44cm×H50cm

Net Weight

70Kg

 

 

 

2. Main Features:

  

1)Wet and dry Integrated Design

This instrument integrated wet and dry dispersion test in one, successfully resolved the   problem of dry and wet technology integration, realize one key to switch.  

 

  • Intelligent full automatic operation system and manual operation, freely choose.

  Choose automatic mode, very easy and simple to learn,support one key operation. 

 

  • Optical Path System patented technology

Converging light Fourier transform path system, enables scattering light be not restricted to the lens aperture limit, and the dual laser orthogonal light use auxiliary semiconductor laser to expand the measurement range by enlarge scattering angle from 45 degrees to 135 degrees.

 

4) Automatic Optical path alignment System,

which is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level,make optimum optical paths to ensure accurate and stable test.

 

5) Full built-in Sample dispersion system.

set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube,  And it guarantees the representativeness of test result.

 

 6)Instrument Software

Original Unconstrained free fitting technology collect scattering data during the measurement process, make particle analysis not be restricted by any functions, truly reflect particles distribution.

   

 

3. Software Function:

 

1, Analysis Mode

Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. meet different demands of particle size statistic in different industries.

 

2,Statistic Method

Volume Distribution, Quantity Distribution

 

3,Statistic Comparison

Statistic Several Testing Results to compare and analyze

Get difference by compare test result of different batches of samples, samples  before and after processing, and different time.

Have great practical significance to industrial raw materials quality control

 

4,User-defined Analysis

Figure out percentage according to the particle size

Figure out particle size according to the percentage

Figure out percentage according to the particle size range

Meet demands of representation of particle test in different industries.

 

5,Test Report

Word, Excel,Photo( Bmp), Text etc.

 

6,Multi-language Support

Chinese&English (Others are available)

 

7,Intelligent Operation Mode

Automatically control water inflow, dispersion,test and analysis.

Better Repeatability after remove human-factor

 

4. Application:  Solid powder, suspension and emulsion.

 

5. Standard Accessories list:

 

NO.

    Items

Quantity

Unit

Remark

1

Winner2309 laser particle size analyzer

1

Set

 

2

Software

1

Set

 

3

Software key

1

PCS

 

4

Standard sample

1

Bottle

 

5

Power cable

1

PCS

 

6

Communication cable

1

PCS

 

7

Sample cuvette

1

PCS

 

8

Screwdriver

2

PCS

 

9

Wrench

3

PCS

 

10

Draining water pipeline

1

PCS

 

11

Standard sample pipeline

1

Set

 

12

Clean mirror paper

3

PCS

 

13

Clean mirror card

1

  PCS

 

14

Sample cuvette brush

2

PCS

 

15

Spoon

2

PCS

 

16

2A fuse

5

PCS

 

17

Quality certificate

1

PCS

 

18

Warranty Card

1

PCS

 

19

Manual

1

PCS

 

 

 

6. Patent Technology:

 

  • Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
  • Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
  • MIE scattering principle application patent No.- ZL 2013 2 0812021.4.
  • Dry particle size analyzer full sealed sample cuvette application is protected by patent No.- ZL.2011 2 0267646.8.
  • Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0
  • Powder dispersion pump design application is protected by patent No.-ZL 2007 2 0018648.7
  • Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2

 

 

 