Neware BTS-4008-5V20mA-S4 8 channels coincell cycler

Neware BTS-4008-5V20mA-S4 8 channels coincell cycler
Model:BTS-4008-5V20mA
Brand:Neware
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument
Label:Neware 8 channels , 5V20mA , coincell cycler
Price: US $1 / pc
Min. Order:1 pc
Inquire Now
点击这里给我发消息

Product Description

Project index Parameter index
Input Power AC 220V ±10% / 50Hz
resolution AD:16bit;DA:16bit
Input Resistance ≥1MΩ
Input Power 709mW
Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode Independent Control
Voltage Voltage Range Charge:10mV~5V;Discharge:10mV~5V
Accuracy ± 0.05% of FS
Stability ± 0.05% of FS
Current Current Range Charge:0.02mA~10mA;Discharge:0.02mA~10mA
Accuracy ± 0.05% of FS
Stability ± 0..05% of FS
Power Per Channel Output Power 25mW
Stability ± 0.1% of FS
Time Current Response Time The Current 10%-90% Hardware Response Time is 10ms
Step Time Range Single Step Time Range≤365*24 h,

 

Time Form Support 00:00:00.000(h、min、s、ms)

Data Recording Record Condition Time△t:(100ms ~60000s)
Voltage△U:(10mV~5V)
Current△I:(0.02mA~10mA)
Record Frequency 10Hz
Charge Charge Mode Constant Current Charge、Constant Voltage Charge、

 

Constant Current and Constant Voltage Charge、Constant Power Charge

End Conditon Voltage、Current、Relative Time、Capacity、-ΔV
Discharge Discharge Mode Constant Current Discharge、Constant Power Discharge、

 

Constant Resistant Discharge、 Constant Voltage Discharge、

Constant Current and Constant Voltage Discharge

End Condition Voltage、Current、Relative Time、Capacity、-ΔV
Pulse Charge Constant Current Charge、Constant Power Charge
Discharge Constant Current Discharge、Constant Power Discharge
Min Pulse Width 500ms
Automated Switch Automated switch from charge to discharge for each pulse
End Condition Voltage, Test Time
Cycle Loop Measure Range 1~65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function,Max Support 3 Layers
Protection Software Protection l Power-down Data Protection
l Off-line Operating
l Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time
Voltage and Current Testing Sample 4-wire connecting
Noise <80dB
Data Management MYSQL Database
Communication Means TCP/IP Protocol
Data Output EXCEL、TXT、Graph
Communication Interface Ethernet Port
Per Unit Main Channels No. 8
Dimensions 3U,480*330*130(mm)
Project index Parameter index
Working Temperature Range 0℃~40℃
Storage Temperature Range 0℃~45℃
Working Environment Relative Humidity Range 30% ~ 80% RH
Storage Environment Relative Humidity Range 30% ~ 90% RH
Equipment Picture 123
Picture for Reference Only, take the material object as the standard.
Neware BTS-4008-5V20mA-S4 8 channels coincell cycler 1Neware BTS-4008-5V20mA-S4 8 channels coincell cycler 2Neware BTS-4008-5V20mA-S4 8 channels coincell cycler 3Neware BTS-4008-5V20mA-S4 8 channels coincell cycler 4Neware BTS-4008-5V20mA-S4 8 channels coincell cycler 5

Member Information

Neware Technology Limited
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:13612950946
Contact:Mathew (sales engineer)
Last Online:19 Dec, 2019