ABC Cables according to BS 7870

ABC Cables according to  BS 7870
Model:ABC
Brand:Unique
Origin:Made In China
Category:Electronics & Electricity / Optical Fiber, Cable & Wire / Power Cable
Label:abc cable , al/xlpe , overhead cable
Price: US $2.1 / M
Min. Order:10000 M
Inquire Now

Product Description

1 Type AL/XLPE            
2 Voltage 0.6/1(1.2)kV            
3 Conductor: Compacted, circular, stranded aluminium 1350-H9            
4 Insulation: Extruded cross-linked polyethylene(XLPE-Black)            
5 Maximum continuous conductor operating temperature of 75 oC.            
                 
Table 1 Ð  Requirements for two-, four- and five- a  core bundles                
  Nominal cross-sectional area of conductors (mm2)
25 35 50 70 95 120
Nominal number of wires in conductor 7 7 19 b 19 b 19 b 19 b
Diameter of conductor            
minimum (mm) 6 7 8 9.3 11.0 12.5
maximum (mm) 7 8 9 10.2 12.0 13.5
Minimum average thickness of insulation (mm) 1 1 2 1.5 1.7 1.7
Minimum thickness of insulation at any point (mm) 1 1 1 1.25 1.43 1.43
Maximum thickness of insulation            
phase core excluding ribs (mm) 2 2 2 2.1 2.1 2.1
neutral core including ribs (mm) 2 2 2 2.3 2.3 2.3
Maximum diameter of core            
phase core excluding ribs (mm) 10 11 12 13.8 16.1 17.6
neutral core including ribs (mm) 10 11 13 14.3 16.6 18.1
Neutral core identification            
number of ribs (min) 12 12 12 16 16 16
Maximum d.c. resistance of conductor in bundle at 20 8C            
(V/km) 1 1 1 0.443 0.320 0.253
Ultimate tensile strength of conductor based on 170 N/mm2            
(calculated) (kN) 4 6 8 11.0 15.3 19.4
a  For two-core bundles, the conductor sizes shall be from 25 mm2  up to and including 95 mm2. For five-core bundles, the phase and neutral cores shall be 50 mm2, 70 mm2  or 95 mm2  and shall conform to the requirements of Table 1. The protective core shall be 25 mm2  and shall also conform to the requirements of Table 1.
b  Subject to a tolerance of  one wire.
                 
                 
6 Identification of phase cores:phase cores are identified by one, two and three continuous
longitudinal ribs
  Identification of neutral core:12 ribs for cores up to and including 50 mm2 and a minimum of 16 ribs for cores above 50 mm2.
7 Lay direction Left hand            
8 Lay ratio: 22 to 28 times the cable diameter            
9 Packing Composite wood reels            
ABC Cables according to  BS 7870 1ABC Cables according to  BS 7870 2ABC Cables according to  BS 7870 3ABC Cables according to  BS 7870 4ABC Cables according to  BS 7870 5