Standalone Keypad Access Control

Standalone Keypad Access Control
Model:L6EM-W
Brand:Lotusmart
Origin:-
Category:Electronics & Electricity / Other Electrical & Electronic
Label:access control , waterproof , night lights keyboar
Price: ¥32 / pc
Min. Order:10 pc

Product Description

 

1. Packing List

Name

 Quantity

Remarks

Keypad

   1

 

User manual

   1

 

Screw driver

   1

Φ20mm×60mm,Special for keypad

Rubber plug

   2

Φ6mm×30 mm, used for fixing

Self tapping screws

   2

Φ4mm×28 mm, used for fixing

Star screws

   1

Φ3mm×6mm, used for fixing

Please ensure that all the above contents are correct. If any are missing please notify the supplier of the unit.

2. Quick Reference Programming Guide

To enter the programming mode

*  Master code  #

999999 is the default factory master code

To exit from the programming mode

 *

Note that to undertake the following programming the master user must be logged in

To change the master code

0  New code  #  New code  #

The master code can be 6 to 8 digits

To add a PIN user.

 

1  User ID number  #  PIN # 

The ID number is any number between 1 & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming mode

To add a card user

1  Read Card  #

Cards can be added continuously without exiting programming mode

To delete a PIN or a card user.

2  User ID number  #  for a PIN user or   

2  Read Card  #  for a card user  

Users can be deleted continuously without exiting programming mode

To unlock the door for a PIN user

Enter the PIN then press #

To unlock the door for a card user

Present the card

3. Description 

The unit is single door multifunction standalone access controller or a Wiegand output keypad or card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case which is available in either a bright silver or matt silver finish. The electronics are fully potted so the unit is waterproof and conforms to IP68. This unit supports up to 2000 users in either a Card, 4 digit PIN, or a Card + PIN option. The inbuilt card reader supports 125KHZ EM cards,13.56MHz Mifare cards. The unit has many extra features including lock output current short circuit protection, Wiegand output , and a backlit keypad. These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons.

4. Features

  • Waterproof, conforms to IP68 
  • Strong Zinc Alloy Electroplated anti-vandal case
  • Full programming from the keypad
  • 2000 uses, supports Card, PIN, Card + PIN
  • Can be used as a stand alone keypad
  • Backlight keys
  • Wiegand 26 input for connection to external reader
  • Wiegand 26 output for connection to a controller      
  • Adjustable Door Output time, Alarm time, Door Open time
  • Very low power consumption (30mA) 
  • Fast operating speed, <20ms with 2000 users
  • Lock output current short circuit protection

Easy to install and program

  • Built in light dependent resistor (LDR) for anti tamper
  • Built in buzzer
  • Red, Yellow and Green LEDS display the working status

5. Specifications 

Operating Voltage

DC 12V±10%

User Capacity

2000

Card Reading Distance

3-6 cm

Active Current

60mA

Idle Current

25±5 mA

Lock Output Load

Max 3A

Alarm Output Load

Max 20A

Operating Temperature

-4560

Operating Humidity

10%- 90% RH

Waterproof

Conforms to IP68

Adjustable Door Relay time

0 -99 seconds

Adjustable Alarm Time

0- 3 minutes

Wiegand Interface

Wiegand 26 bit

Wiring Connections

Electric Lock, Exit Button, External Alarm,External reader

6. Installation

  • Remove the back cover from the keypad using the supplied special screw driver
  • Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
  • Put the supplied rubber bungs to into the two holes
  • Fix the back cover firmly on the wall with 2 Self tapping screws
  • Thread the cable through the cable hole
  • Attach the keypad to the back cover.
     

7. Wiring

Colour

Function

Description

Pink

BELL_A

Doorbell button one end

Pale blue

BELL_B

Doorbell button to the other end

Green

D0

WG output D0

White

D1

WG output D1

Grey

ALARM

Alarm negative(alarm positive connected 12 V+)

Yellow

OPEN

Exit button one end(the other end connected GND)

Brown

D_IN

Magnetic switch one end(the other end connected GND)

Red

12V+

12V + DC Regulated Power Input

Black

GND

12V - DC Regulated Power Input

Blue

NO

Relay normally-on end(Connect positive electric lock "-")

Purple

COM

Relay Public end, connect GND

Orange

NC

Relay Closed end(connect negative electric lock "-")

 

  common power supply diagram: 

 

            

special power supply diagram:

 

8. To Reset to Factory Default

      a. Disconnect power from the unit

      b. Press and hold # key whilst powering the unit back up

      c. On hearing two “Di” release # key, system is now back factory settings

      

Please note only installer data is restored, user data will not be affected

9. Anti Tamper Alarm

The unit uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate.

10.Sound and Light indication

Operation Status

Red Light

Green Light

Yellow Light

Buzzer

Power on

-

Bright

-

Di

Stand by

Bright

-

-

-

Press keypad

-

-

-

Di

Operation successful

-

Bright

-

Di

Operation failed

-

-

-

DiDiDi

Enter into programming mode

Bright

-

-

 

In the programming mode

-

-

Bright

Di

Exit from the programming mode

Bright

-

-

Di

Open the door

-

Bright

-

Di

Alarm

Bright

-

-

Alarm

 

11. Detailed Programming Guide 

11.1 User Settings

To enter the programming mode

 *  Master code #

 999999 is the default factory master code

To exit from the programming mode

 *

Note that to undertake the following programming the master user must be logged in

To change the master code

 0  New code  #  New code #

The master code can be 6 to 8 digits long

Setting the working mode:

Set valid card only users

Set valid card and PIN users

Set valid card or PIN users

   

 3   0   #  Entry is by card only

 3   1   #  Entry is by card and PIN together

 3   2   #  Entry is by either card or PIN (default)

To add a user in either card or PIN mode, i.e. in the 3   2   #  mode. (Default setting)

To add a Pin user

1  User ID number  #  PIN # 

The ID number is any number between 1 & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming mode as follows:

1  User ID no 1 #  PIN # User ID no 2 #  PIN #

To delete a PIN user

2  User ID number  #  

Users can be deleted continuously without exiting programming mode

To change the PIN of a PIN user 

(This step must be done out of programming mode)

 *  ID number #  Old PIN #  New PIN #  New PIN #

To add a card user (Method 1)

This is the fastest way to enter cards, user ID number auto generation.

1  Read card  #

Cards can be added continuously without exiting programming mode

To add a card user (Method 2)

This is the alternative way to enter cards using User ID Allocation. In this method a User ID is allocated to a card. Only one user ID can be allocated to a single card.

1   ID number  #  Read card  #

User can be added continuously without exiting programming mode

To add a card user (Method 3)

Card number is the last 8 digits printed on the back of the card,user ID number auto generation

1  Card number  #

 User can be added continuously without exiting programming mode

To add a card user (Method 4)

In this method a User ID is allocated to a card number. Only one user ID can be allocated to the card number

 

 1  ID number. #  Card number. #

User can be added continuously without exiting programming mode

To delete a card user by card. Note users can be deleted continuously without exiting programming mode

2   Read Card    #

To delete a card user by user ID. This option can be used when a user has lost their card

2   User ID   # 

 

To delete a card user by card number.

This option can be used when the user want to make the change but the card has lost

2   Card number    #

Note users can be deleted continuously without exiting programming mode

To add a card and PIN user in card and PIN mode (3   1   # )

To Add a card and Pin user

(The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved.)

Add the card as for a card user

Press  * to exit from the programming mode

Then allocate the card a PIN as follows:

 *  Read card 1234 # PIN # PIN #

To change a PIN in card and PIN mode (Method 1) Note that this is done outside programming mode so the user can undertake this themselves

 *  Read Card  Old PIN #   New PIN #   New PIN #

 

To change a PIN in card and PIN mode (Method 2) Note that this is done outside programming mode so the user can undertake this themselves

 *  ID number #  Old PIN #   New PIN #  New PIN #

 

To delete a Card and PIN user just delete the card

2   User ID   #

To add a card user in card mode (3   0   # )

To Add and Delete a card user

The operating is the same as adding and deleting a card user in 3   2   #

To delete All users

To delete ALL users. Note that this is a dangerous option so use with care

2   0000   #

To unlock the door

For a PIN user

Enter the PIN  then press #

For a card User

Read card

For a card and PIN user

Read card then enter PIN #

 

11.2 Door Settings

Relay Output Delay Time

To set door relay strike time

*  Master code #  4   099   # *

0-99 is to set the door relay time 0-99 seconds

Door Open Detection

Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically.

Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is forced open, or if the door is opened after 20 seconds ,the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0-3 minutes with the default being 1 minute.

To disable door open detection. (Factory default)

 6   0   #

To enable door open detection

 6   1   #

Alarm output time

To set the alarm output time (0-3 minutes) Factory default is 1 minute

 5   03   #

Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and the inside buzzer will operate for 10 minutes, depending on the option selected below.

Normal status: No keypad lockout or alarm (factory default)

 7   0   # (Factory default setting)

Keypad Lockout

 7   1   #

Alarm and inside buzzer operate  

 7   2   #

To remove the alarm

To reset the Door Forced Open warning

<</diyep:docbody>
Standalone Keypad Access Control 1Standalone Keypad Access Control 2

Member Information

Chongqing Lotussmart technology co.
Country/Region:Chong Qin - China
Business Nature:Manufacturer
Phone:17754975747
Contact:Jade (Sale Director)
Last Online:03 Jul, 2019