Model: | ECO-800 |
---|---|
Brand: | ECO |
Origin: | Made In China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | electrosurgical unit , generater |
Price: |
US $1500
/ pc
|
Min. Order: | 1 pc |
Functions
This instrument is indicated for the cut and coagulation surgery of tissues in surgeries
Specifications
Voltage:AC 220V 50Hz
Maximum output power
Mode |
Rated output power |
ECO-800A |
350W |
ECO-800B I |
300W |
ECO-800B II |
200W |
ECO-800B III |
100W |
Working frequency :512 kHz/300kHz
CF type equipment
Input power:≤600VA+10%
Unit size: 40cm * 42cm * 16cm
Weight: 18kgs
Characteristics
.Cut output power:0-350W, coagulation output power: 0-200W
.Six cut modes : High Power cut (ECO-8000A), Pure,Blend1,Blend2, Blend3, Endo cut
.Four coagulation Modes: Forced,Soft, Spray, Bipolar
.Monopolar and Bipolar auto-exchange
.Peak Power System(PPS) : Auto adjust power
.Spray coagulation is good for superficial coagulation.
.Wider Impedance Recognition(50-1800Ω), meeting all kinds of operation environment
.Neutral electrode Safety system(NESSY), continuously monitor neutral electrode
.Less smoke under power.
ENDO-CUT available to work with different coagulation mode
.Application
General surgery, orthopedics, gynecologic, urological,cardiac surgery, anus intestines, tumor surgery department and etc.
Endoscopic surgery under endoscope, celoscope and cystoscope;
Neurosurgery, microsurgery, E.N.T and Plastic surgery department under low power
.Model parameters
Mode |
Matching Impedance |
Basic Parameters |
Product Model |
|||
ECO-800A |
ECO-800BI/D |
ECO-800BII/D |
ECO-800BIII |
|||
Cut |
|
|
|
|
|
|
High Power |
400Ω |
Power |
350W |
300W |
/ |
/ |
Basic frequency |
300KHZ |
300KHZ |
||||
Pure |
Power |
300W |
250 W |
200W |
100 W |
|
Basic frequency |
300KHZ |
300 KHZ |
300 KHZ |
300 KHZ |
||
Blend1 |
Power |
150W |
150 W |
150 W |
80W |
|
Basic frequency |
512KHZ |
512 KHZ |
512 KHZ |
300 KHZ |
||
Blend2 |
Power |
120W |
120 W |
120 W |
60W |
|
Basic frequency |
512KHZ |
512 KHZ |
512 KHZ |
300 KHZ |
||
Blend3 |
Power |
80W |
80 W |
80 W |
/ |
|
Basic frequency |
512 KHZ |
512 KHZ |
512 KHZ |
|||
Endo |
|
Power |
120W |
120 |
80 W |
/ |
Basic frequency |
512 KHZ |
512 |
512 KHZ |
|||
Bipolar cut |
250Ω |
Power |
350W |
/
|
/ |
/ |
Basic frequency |
100KHZ |
|||||
Coagulation |
|
|
|
|
|
|
Soft |
400Ω |
Power |
150W |
150 W |
150 W |
/ |
Basic frequency |
512KHZ |
512 KHZ |
512 KHZ |
|||
Forced |
Power |
120W |
120 W |
120 W |
100 W |
|
Basic frequency |
512KHZ |
512 KHZ |
512 KHZ |
300 KHZ |
||
Spray |
Power |
100W |
100 W |
100 W |
/ |
|
Basic frequency |
512KHZ |
512 KHZ |
512 KHZ |
|||
Bipolar coa. |
50Ω |
Power |
80W |
80W |
80 W |
80 W |
Basic frequency |
300KHZ |
300KHZ |
300 KHZ |
300 KHZ |
Effect for cutting modes:
1- High cut: the model of 300W and above the energy , the model for underwater vaporization electric resection, can achieve the desired cutting effect.
2- Pure cut: similar to the effect of scalpel cutting , apply to fine and non-invasive cutting of any tissues.
3- Blend 1 cut : cutting along with mild clotting effect. For orthopedic surgery, flap separation, large blood vessels around the tissue separation.
4- Blend 2 cut : cutting along with moderate coagulation. Applicable to general, chest, laparoscopic cut, bleeding and other surgery.
5- Blend 3 cut: cutting along with stronger coagulation effect than the blend 2 cut . Applicable to the demolition of the breast, general surgery, orthopedics and so on.
6- ENDO cut: in the endoscopic conditions, the operator couldn’t directly control the operation process and set up a program called "ENDO CUT", refer to the actual clinical needs, flexible to set the output power of electric cut and coagulation, to achieve a more ideal surgical results.
7- Bipolar cut: unique in the saline , the cutting effect is caused by the Kinetic Energy Ion generated in Bipolar Vaporization, which can achieve the effect of rapid removal of tissue at low temperature, to avoid the occurrence of congestive edema and water poisoning.
8-Soft coagulation: Touched hemostasis, coagulation,are conducive to the wound healing after surgery. Suitable for rapid touched coagulation in luminal surgery and other fine tissue surgeries.
9-Forced coagulation: touched hemostasis, coagulation, Electron-coagulation effect is stronger, usually called point coagulation.
10-Spray coagulation: surgical electrodes and biological tissue can be without touching , apply to stop bleeding of a large area . The Electron-coagulation effect is strong, usually called surface coagulation (working with argon gas controller can produce argon ions for coagulation).
11-Bipolar coagulation: for neurosurgery or ordinary bipolar coagulation surgery. To achieve the tissues or vascular coagulation function in the middle two tweezers.
12-Bipolar Electro-coagulation: unique in the saline,the electro-coagulation effect is caused by the Kinetic Energy Ion generated in Bipolar Vaporization,
which can achieve the effect of rapid hemostasis and Coagulation at low temperature, to avoid the occurrence of congestive edema and water poisoning.
Nanjing kaihong healthcare co.,ltd | |
---|---|
Country/Region: | Jiang Su - China |
Business Nature: | Manufacturer |
Phone: | 13371915 |
Contact: | Rainy Day (sales) |
Last Online: | 20 Apr, 2016 |