Model: | RDY-DC10KW |
---|---|
Brand: | Ruidayi |
Origin: | Made In China |
Category: | Consumer Electronics & Lighting / Heaters |
Label: | Domestic heating dev , Electromagnetic heat , 10 kW electromagneti |
Price: |
¥4000
/ pc
|
Min. Order: | 1 pc |
I. electrical parameters
Rated voltage: AC - 220V/50Hz - AC 380V/50Hz
Rated power: - 2KW - 3.5KW - 5KW - 6KW - 7KW - 8KW
- 9KW - 10KW - 12KW - 15KW - 20KW
- 25KW - 30KW - 40KW - 50KW
Voltage range: AC 165V- AC 275V
Two, product size:
1:500*400*200mm (length * width * height) (2KW-6KW)
2: 750*400*200mm (length * width * height) (7KW-10KW)
3: 900*500*320mm (length * width * height) (15KW-25KW)
4: 1130*600*550mm (length * width * height) (30KW-50KW)
Three, the use of environment:
Temperature: -15 to +55
Humidity: <90%
Four. Performance description
1. thermal efficiency is more than 90%
2. power factor: 0.98
3. working frequency: 17KHz - 30KHz
The function of automatic adjustment of 4. power: according to the current, voltage, frequency, temperature and other related factors,
The MCU is automatically adjusted to the maximum, the best power for improving the product life.
Five, protection function:
1.IGBT over temperature protection: 85 + 5
2.IGBT high voltage protection: 1050V
3. overcurrent protection: Hardware + software intelligent dual protection mode
4. surge protection: protection mode of dual intelligent hardware + software
The 5. phase tracking protection: Hardware + software intelligent dual protection mode
6. coil short circuit protection: Hardware + software intelligent dual protection mode
Six, motherboard socket interface description
1. isolation DC12V: isolated power supply control panel. (control panel must be isolated)
2. interface: to control the data control block of electromagnetic heater plate transmission interface.
3. working switch: opening and closing of the whole machine.
Function description of control panel
First, use the basic conditions:
1. power supply voltage range: input voltage 220V + 10%
2. AC input power frequency: 50Hz
3. working environment temperature: -30 to +70 centigrade
4. working environment humidity: RH20%~95
5. temperature setting range: +20 to +85 centigrade
Two, accessories parameters:
Temperature sensor: R25:100K + 1% 3950K + 1%
Three, functional overview:
1. automatic operation mode: three (2KW to 50KW) timing open and shut down.
2. overtemperature fault protection
3. dry burning fault protection
4. low temperature anti icing protection function
5. sensor fault prompt
6. buzzer beep tips
7. water temperature and room temperature display
8. infrared remote control function
Four, display pattern:
Five, button and function description
1. host buttons:
Host four buttons were "switch (S1), set (S2)",
"+ (S3)" and "- (S4)""
2. remote control button:
The five keys of the remote controller are "switch", "setting" (function), "+", "-" and "automatic"".
3. open, key:
After switching on the power, press the "switch" button once: the machine will follow the last set of working mode to start the work. Under the working state press the switch button once: shutdown stop working.
4. set the (function) key:
During the setting process with "+" and "-" button; press the set button (function), if 3 seconds without any key operation, save the settings and return; in the boot state long press "set (function)" button 2 seconds later (at the same time there will be a "tick" sound continuous ringing two times) to the clock and timer switch machine set.
5.+, - bond:
With the "settings (function)" key used; in the boot state, if directly press "+" and "-" key, adjust the current period of setting temperature is high and low.
6. timing on and off time:
If the timing of opening and closing time is set at the same time to open, there is no shutdown function.
When the clock is running to the set time, if the machine will automatically boot in standby state; the machine is not executed under the boot state. When the clock runs to the set timing shutdown time, if the system is in the state of automatic shutdown, the system is not executed under the shutdown state.
7. water temperature and room temperature:
The temperature control of temperature, when the water temperature reaches the set temperature to stop heating, insulation (insulation) when the actual temperature reaches the set temperature of -5 DEG C when re heating; just do not show room temperature, water temperature and room temperature control; turn display.
8. Over temperature protection:
When the temperature of the liner or coil exceeds 125 degrees, the machine automatically stops heating and restores automatically when the temperature of the inner liner or coil is lower than 125 degrees.
9. Slope dry burning protection:
When the temperature of the inner liner or coil is increased by more than 3 degrees in 3 seconds, it is judged that the inner liner is dry, the machine stops heating automatically, the temperature rise slope is returned to normal, and the machine automatically returns to normal work.
10. Low temperature anti icing protection:
Water temperature is less than 5 degrees, the machine does not need to start the system automatically start work, water temperature heating to 10 degrees, the machine insulation at this temperature point.
Setting instructions
An ordinary operation (this is suitable for simple operation)
1. press the "switch" key machine to default the most high-grade power, to the last set of water temperature work;
2. according to the function keys can set the power stalls and set the water temperature (with the "+" - "-" key to achieve the set);
Two, advanced operation
1. click "switch" button, the machine starts to work; long press "set (function)" button for 3 seconds will be "beep" twice to enter the following advanced settings:
1.1 clock setting
1.2 gear selection (1-3 files optional; 1 files 1 main board work; 2 files 2 main board work; 3 files 3 main board work); this function 8-12KW practical
1.3 timing set, shutdown settings (the machine can be set according to the needs of one to three periods of time to open, shut down; three periods can not cross, between the time interval and the time interval should be set at least 1 minutes;
The water temperature setting in the first period is the starting time of the first period and the first stopping time
Second time water temperature setting: second time interval start time, second time shutdown time
Third time water temperature setting: third time interval start time, third time shutdown time
2. long press "set (function)" button to return to the default boot state clock;
3. long press "-" key 3 seconds into the automatic state, at this time, except the key, the rest of the key failure,
The machine according to the set time automatically.
Examples of timing on / off operation:
For example: 8:00 in the morning began to boot to the 12:00 shutdown, the water temperature is 60 DEG C (the first time); at 14:00 17:00 to boot shutdown, the water temperature is 40 C (second hours); at 19:00 00:00 to boot shutdown, the water temperature is 50 C (third hours); is set according to the following steps:
Step 1: click the "switch" button, the machine starts to work
Step II: long press "set (function)" button for 3 seconds (there will be a "beep" twice) into the clock calibration (at the top left corner of the screen will flash, digital time) according to the "+" and "-" to adjust the time for the local time (according to the "+" to adjust the clock, press "- to adjust the minutes)
Step 3: press "set (function)" button once to enter the setting temperature (at the upper right corner of screen will flash, digital) according to the "+" and "-" to adjust the temperature of 60 DEG C (press "+" to increase the temperature, press "-" to reduce the temperature)
Step 4: click "settings (function)" button once to enter the first time start time (at the top left corner of the screen will flash digital time at the same time, the lower left corner of the "timing" bright), according to the "+" and "-" the adjustment time is 8:00
Step 5: press "set (function)" button once to enter the first period of time off (at the top left corner of the screen will flash digital time at the same time, the lower left corner of "time off" bright), according to the "+" and "-" the adjustment time is 12:00; 3, 4, 5, repeat steps second times and the third time set set; after a pause for three seconds according to "switch" button once to return to the standby state, long press "-" key to enter the automatic state.
If you only set two time interval timer, the switch time of the third time is set at the same time point (this time point should be greater than the shutdown time of second periods)
Three, pay attention to:
1. electromagnetic heating device (water heater) is from the bottom of the water, above the water, in the water should be paid special attention to prevent water bile partial dry burning;
2. pay attention to the installation of the inlet and outlet can not be blocked by other items, maintain a good ventilation state, in order to long-term stable work.
Four, the application of the port and the internal wiring principle diagram
Five, installation notes
1. check whether the new machine is damaged by transportation.
2. packaging materials and old machines should be according to the standard of environmental protection to deal with.
3. please read the instructions carefully and keep them carefully.
4. before installation, professional personnel should be required to check the over-current capacity of the power supply line and the power through of the meter
Whether the flow capacity meets the requirements of current passing above A of the machine.
5. a reliable grounding wire must be installed.
6., three phase leakage automatic switch and air switch (over A capacity) must be installed,
Please switch off the external leakage switch when not in use.
7. heating furnace must be vertical installation, from the next into the cold water on the top, after the connection of the water to power
Test machine.
8. shall be installed in the heating furnace from the combustible and strong magnetic field too close to the place.
9., in order to prolong the service life of heating furnace, the working environment of heating furnace must be moistureproof, dustproof, shockproof, waterproof and sunscreen.
10. the inlet and outlet pipes of the heating furnace are connected by 4 points or more pipes to ensure the good circulation of the water.
11. before starting the first confirmation of the circulating water system without clogging or air resistance.
12. when starting the test machine, if it is found that there is water leakage in the inlet and outlet, it should be immediately shut down and screw in the water
Tube, water dry and then boot, otherwise it may burn out the motherboard.
13. the inlet and outlet of the machine must be unblocked, otherwise it will damage the machine.
14. prohibited will block the inlet and outlet of heating furnace after ohmic heating.
15. the power line must be purchased and connected according to the power line at the outlet of the junction box.
16. if the power cord is damaged, don't try to fix it and fix it in your local electrical store.
17. the device for heating the furnace must be solid and reliable and must be able to withstand the weight of 20KG.
18. heating stove must be installed in children can not touch the position, in order to prevent accidents.
Six. Installation schematic diagram
Seven, common troubleshooting
Troubleshooting method of fault phenomenon
The motherboard stop heating, LED2, LED3 alternating light. The temperature of dry heating in slope fault check whether there is water and water is normal
The motherboard stop heating, LED1, LED3 alternating light. The current slope dry heating body fault check whether there is water and water is normal
The motherboard stops heating and LED3 shines. The high temperature heating coil body check whether there is water and water is normal
The main board stops heating and LED3 is long. Coil sensor (short) temperature sensor fault coil is pl ed in
The motherboard stops heating and LED2 shines. Motherboard IGBT high temperature
The main board stops heating and LED1 and LED2 are long. IGBT temperature sensor open (short) path fault
The motherboard stop heating, LED1, LED2, LED3 shining. No detection coil or no heating coil is connected to check
The control panel displays E1 or E2. Water temperature thermistor thermistor (short) open path fault check water temperature is well connected.
Payment Terms: | TT |
---|---|
Shenzhen City Rui Dayi Technology Co. Ltd. | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 13286651066 |
Contact: | Mr. Xiang (Sales Manager) |
Last Online: | 02 Nov, 2017 |