Micro magnetic dc pump 50C

Micro magnetic dc pump 50C
Model:RN50C
Brand:RUNNE
Origin:Made In China
Category:Industrial Supplies / Machinery / Pumps Vacuum Equipment
Label:dc magnetic pump , Mini magnetic pump , micro magnetic pump
Price: -
Min. Order:10 pc

Product Description

Micro magnetic pump DC50C

Micro magnetic pump DC50C

Date:2015/06/01 Views:830

 

DC50C Series

Product Appearance

Specifications

NO. Item Specs
1 Dimension and weight 106mmx97.5mmx71.5mm;480g
2 External diameter of outlet 1/2” thread(M20)
3 External diameter of inlet 1/2” thread(M20)
4 Driving mechanism Brush-less, magnetic isolated design
5 Material of pump shell ABS,PES/SPS/PPS/PA66+30%GF (Optional)
6 Condition of use Can continuously work, submersible or land use (not self-priming)
7 Suitable medium Water, oil, or normal acid/ alkaline liquids
(Pre-test needed for special liquid)
8 Max working temperature 60℃(for T sub-series) or 100℃(for S/A sub-series)
9 Power consumption 2.5W~48W(for T sub-series) or 2.5W~86.4W(for S/A sub-series)
10 Rated voltage 12Vdc or 24Vdc
11 Working voltage range 5Vdc ~ 14Vdc or 5Vdc ~ 26Vdc
12 Max load current 2.0A (for T sub-series) or 4.5A(for S/A sub-series)
13 Max horizontal flow rate 32L/MIN(for T sub-series) or 40L/MIN(for S/A sub-series)
14 Max static lift 4M(for T sub-series) or 8M(for S/A sub-series)                                  
15 Noise class <40dB
16 Waterproof class IP68(suitable for submersible installation)
17 Life span >30,000hrsIP68(suitable for submersible installation)
18 Power supply Suitable solar panel, batteries, adapter or other power source
19 Protection function Dry-run protection, lock protection(customized function)
20 Power regulation function Speed adjustable by PWM signal, 0~5V analog signal or potentiometer (functions are optional for customization)
22           Feature
  • small size with high efficiency,maintenance-free
  • Use ceramics shaft and carbon fiber sleeve
  • Completely water proof (IP68)
  • Brush-less dc control without pollution, long life span
  • OEM and ODM service accept
  • Offer Pump related control system design

 

Pump Structure

Electrical parameters (only for reference,parameters can be customized for specific requirements)

​​

Model No. Voltage Max load current Max static lift Max flow rate Power consumption
  V(dc) A M L/H w
DC50C-1230T 12 2.0 3.0 1680 24
DC50C-1230S
DC50C-1230A
DC50C-1260S 12 4.5 6.0 2100 54
DC50C-1260A
DC50C-2440T 24 2.0 4.0 1920 48
DC50C-2440S
DC50C-2440A
DC50C-2480S 24 3.60 8.0 2400 86.4
DC50C-2480A
     NOTE
  •  Information including continuous working time, working temperature and medium is required to be pre-confirmed with professionals; pump cannot work with high temperature or corrosive fluids.
  •  When pump is connected into circulation system, load current will be reduced to 70~85% of Max working current (opening outlet current).
  •  The head means the Max vertical lifting height of water,the flow is 0L/MIN@max head.
  •  The max flow rate means flow rate with no lifting height(according to the curve bellow)

 

Difference between 2phase & 3phase brushless DC pump

   2phase 
(T sub-series)
 Hall sensor driving, circuit board should be placed inside pump body
   3phase
(S/A sub-series)
  • NOTE that 3phase dc is completely different with 3phase AC; 3phase DC means 3 pairs of magnetic polarity & sensor-less, power supply  the same with common DC pump
  • Intelligent program-driving, sensor-less, circuit outside of pump body (main factor that pump can be high-temperature resistant)
  • Speed adjustable by PWM, 0~5V signal or potentiometer(optional)
  • Lock protection,reverse-connected protection, over-vol.&over-current protection,
  • Soft start, no current impact, can be contact directly with solar panel


 

                   
Potentiometer Speed adjusting connection:
Contact the red and black wire to both ends of potentiometer(variable resistor),then contact the yellow wire to the middle of potentiometer,Speed canbe changed by turning the potentiometer. Potentiometer speed adjusting is the same with VR speed adjusting(Remove the potentiometer and contact the speed adjusting wire like VR speed adjusting connection bellow).
PWM(50-800HZ/Amlitude 5V) or VR(0-5V) Speed adjusting connection:
Contact the yellow wire to the control system's speed control signal output interface(PWM or VR) and contact the black wire to the ground lead in the control system.hang the red wire on the air.

Flow rate-Head Curve 

Dimensions of pump

​​

production test

 

Exploded diagram of the product 

 Selection guide

 

Model Voltage
(DC)
Current range Max lift Max flow   Inlet Dimension Outlet Dimension Speed regulation function Dry-run / Lock protection
DC30A 5~12V 0.1~0.35A 3m 4L/MIN 8mm 8mm customized Optional
DC40 6~24V 0.15~1.2A 8m 11L/MIN 14mm 10mm PWM/0~5V/manual Optional
DC40A 6~24V 0.15~1.2A 6m 14L/MIN 14mm 14mm PWM/0~5V/manual Optional
DC40C 6~24V 0.15~1.2A 6m 15L/MIN 1/2’’thread 1/2"thread PWM/0~5V/manual Optional
DC40D 6~24V 0.15~1.2A 8m 10L/H 10mm 10mm PWM/0~5V/manual Optional
DC40F 6~24V 0.15~1.2A 6m 16L/MIN 1/2’’thread 1/2"thread PWM/0~5V/manual Optional
DC40H 6~24V 0.15~1.2A 11m 7.5L/MIN 11mm 8mm PWM/0~5V/manual Optional
DC50 6~24V 0.15~3.8A 7m 44L/MIN 22mm 22mm PWM/0~5V/manual Optional
DC50A 6~24V 0.15~3.8A 5m 60L/MIN 27mm 27mm PWM/0~5V/manual Optional
DC50B 6~24V 0.15~3.8A 13m 30L/MIN 22mm 22mm PWM/0~5V/manual Optional
DC50C 6~24V 0.15~3.8A 6.5m 42L/MIN 1/2’’thread 1/2"thread PWM/0~5V/manual Optional
DC50D 6~24V 0.15~3.8A 6.5m 42L/MIN 20mm 20mm PWM/0~5V/manual Optional
DC50E 6~24V 0.15~3.8A 15m 25L/MIN 1/2’’thread 1/2"thread PWM/0~5V/manual Optional
DC50F 6~24V 0.15~3.8A 15m 25L/MIN 1/2’’thread 1/2"thread PWM/0~5V/manual Optional
DC50G 6~24V 0.15~3.8A 8m 40L/MIN 14mm 8mm PWM/0~5V/manual Optional
DC50K 6~24V 0.15~3.8A 16m 23L/MIN 14mm 14mm PWM/0~5V/manual Optional
DC50W 24V 1~3.8A wave 28000L/H Submersible 58mm Variable Frequency Optional
DC50Q 24V 1~3.8A 5m 5000 L/H 1’’ thread 1"thread Variable Frequency Optional
DC60Q 24v 1-5A 5m 10000L/H 1.2’’thread 1.2"thread Variable Frequency Optional
Note:
1, lift and flow rate of product can be customized
2, dimension of inlet/outlet, speed adjusting method and control system can be customized.
3,Food grade and mute pump can be customized.
 

 

 

Installation


 

Payment Terms:TT,PAYPAL
Micro magnetic dc pump 50C 1Micro magnetic dc pump 50C 2Micro magnetic dc pump 50C 3Micro magnetic dc pump 50C 4Micro magnetic dc pump 50C 5

Member Information

Shenzhen Zhonghong Huarui technology Co.,Ltd
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:15813728602
Contact:Mars (sales manager)
Last Online:23 Jun, 2022