Medium Voltage Split Core Current Transformer

Medium Voltage Split Core Current Transformer
Model:LZCK322-10
Brand:GFUVE
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument
Label:current transformer , AC current transform , ac clamp on current
Price: US $120 / pc
Min. Order:3 pc
Inquire Now

Product Description

Detailed Product Description

Name:

Split Core Current Transformer

Application:

Energy Meter

Usage:

Current Measurement

Theory:

Electromagnetic Induction

Material:

Epoxy Resin And Supercrystalline Alloy

Ratio:

100-1000A/5A Or 1A

Accuracy:

0.5%

Burden:

2.5-10VA

Diameter:

50mm

Color:

Red & Black

 

Features
New magnetic material is taken to be the core of the current transformer, which has high magnetic permeability, low saturation magnetization and good stability. Therefore, the measuring accuracy is higher and the instrument security factor is lower. Since the high quality silicon processed by advanced technology is taken to be the core of the protection windings, which assured the accuracy limit factor is higher.
The semicircular ring core and secondary windings are vacuum poured by high quality epoxide resin in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance.Small size, light weight, small footprint, fixed in the ring network switchgear cable.The cable can cross the current transformer through its internal poles quickly and uniformly.
The Cast Resin Straight-Through Current Transformer can be divided several kinds according to the various current ratio, accuracy and rated loads. The specific parameters are showed in the corresponding to each model parameter tables.

 

Theory

Split core current transformers are high accuracy class electrical devices used to isolate or transform voltage or current levels. The most common usage of current transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. The primary winding of the transformer is connected to the high voltage or high current circuit, and the meter or relay is connected to the secondary circuit. Installation With electricity, suite for power monitor, energy loss etc.

Split core current transformers may also be used as an isolation instrument transformer so that secondary

quantities may be used in phase shifting without affecting other primary connected devices.

 

Applications
Spit core current transformers are the current-sensing units of the power system. Split core current transformers are used at generating stations, electrical substations, and in industrial and commercial electric power distribution.
LZCK322-10 split core current transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes.The transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.

 

PARAMETERS

Technical parameters 

Standards

IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13

Accuracy Class

0.5S, 0.5%, 1%, 3%

Range of primary rated current

100-1500A

Range of Rated load

≤10VA

Rated frequency

50/60Hz

Rated secondary current

5A or 1A

Rated short-time thermal current

40kA, 1S

Rated continuous thermal current

150%I1n

Secondary winding power frequency withstand voltage

3kV, 1min

Safety Factor Rating

(FS) <10

Output signal

1A, 5A, 333mV, 1V or 5V(customized)

Cable length

2.5m, 5m, 10m(customized)

Flame retardant ABS plastic shell inside, jaw waterproof apron.

Mechanical parameters 

Aperture (mm)

Φ55

Dimensions (W×D×H) (mm)

180×138×52

Weight (kg)

2

Working conditions 

Operating temperature

-35°C to +65°C, not exceeding +40°C

Storage temperature

-40°C to +70°C

Ingress Protection

IP65

Environment

outdoors or indoors

The Height of above sea level

0- 3000m

Conditions

No existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed.

 

 

SELECTION GUIDE

Technical parameters 

Standards

IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006

Rated primary current

30-600A

Rated load

≤10VA

Rated frequency

50Hz or 60Hz

Rated secondary current

5A or 1A

Rated short-time thermal current

40kA, 1S

Rated continuous thermal current

120%I1n

Secondary winding power-frequency voltage

3kV, 1min

Instrument security factor

FS≤10

Mechanical parameters 

Dimensions (W×D×H) (mm)

φ50xφ110x52

Weight (kg)

1.6

Operating conditions 

Operating temperature

-35°C to +55°C

Daily average temp

<+40°C

Altitude

<3500 meters

Condition

No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

 

TECHNICAL DATA

Type

LZCK322-10

LZCK322-10

Purpose

Measuring current transformer

Protection current transformer

Ratio

Accuracy class and rated load(VA)

Accuracy class and rated load(VA)

I1/I2

0.5

1

3

10P15

10P10

10P5

30/1

 

1

1.5

 

 

 

50/1

 

1

2

 

 

1.25

75/1

 

1.5

2.5

 

1

2

100/1

2

2.5

3

 

1.5

2.5

200/1

2.5

 

 

1.25

2.5

 

300/1

3.75

 

 

1.25

2.5

 

400/1

7.5

 

 

1.25

2.5

 

500/1

10

 

 

1.25

3

 

600/1

10

 

 

1.5

3

 

50/5

 

 

2.5

 

 

 

75/5

 

 

2.5

 

 

 

100/5

2.5

 

 

 

 

 

200/5

3.75

 

 

 

 

 

300/5

5

 

 

 

 

 

400/5

7.5

 

 

 

2.5

 

500/5

7.5

 

 

 

2.5

 

600/5

10

 

 

 

3.75

 

 

SELECTION GUIDE

Model

Primary rated current

Rated load

Aperture (mm)

Description (mm)

Weight (kg)

Material

Water-proof

LZCK-55

100-1500A

≤10VA

φ55

180×138×52

2

PC

IP65

LMCK185-10

300-3000A

≤25VA

φ185

350×283×55

4.5

PC

IP65

LZCK310-10

300-600A

≤10VA

φ50

φ50 x φ110 x 32

1

Resin

silicon case (option)

LZCK322-10

30-600A

≤10VA

φ50

φ50 x φ110 x 52

1.6

Resin

silicon case (option)

LZCK350-10

20-600A

≤25VA

φ50

φ50 x φ110 x 105

3.1

Resin

silicon case (option)

LZCG530-10

30-600A

≤20VA

φ45

φ45 x φ120 x 65

2.1

Resin

silicon case (option)

 

 

Medium Voltage Split Core Current Transformer 1Medium Voltage Split Core Current Transformer 2Medium Voltage Split Core Current Transformer 3Medium Voltage Split Core Current Transformer 4Medium Voltage Split Core Current Transformer 5

Member Information

Beijing GFUVE Electronics Co.,Ltd
Country/Region:Beijing - China
Business Nature:Manufacturer