Air Quality Chlorine Cl2 Gas Detector Sensor Disinfectant Toxic Electrochemical

Air Quality Chlorine Cl2 Gas Detector Sensor Disinfectant Toxic Electrochemical
Model:Cl2/MF(C)(S)-**
Brand:Membrapor
Origin:Made In Switzerland
Category:Electronics & Electricity / Electrochemical Products
Label:Membrapor , Chlorine , Cl2
Price: US $145 / pc
Min. Order:1 pc
Inquire Now

Product Description

Gas Module Introduction
FAD gas module with two/three wire TTL/0-20mA/RS485 output, integrates toxic gas sensor + transmitter board. Adopting imported advanced electrochemical gas sensors, it has features of high accuracy, long lifetime, high stability and high anti-interference. The module is designed to prevent circuit reversed connection, high voltage, high current and lightning.
 

Gas Module Feature

- Long lifetime imported advanced electrochemical sensors

- High accuracy op ams, power supply IC, stable and sensitive

- Detect low or high concentration toxic gases precisely

- High anti-interference ability

- Over range protection, reversed polarity protection and lightning protection

- Low power consumption with a standard 4-20mA two/three-wire signal output

- Interface: pump, diffusing, flange, flange thread types

- 12-36VDC operating voltage

Detecting Range Selection

Detecting range (ppm)/Size Miniature Compact Slim Standard
0-20 Cl2/M-20 Cl2/C-20 Cl2/S-20-S Cl2/S-20
0-50     Cl2/S-50-S Cl2/S-50
0-200 Cl2/M-200 Cl2/C-200 Cl2/S-200-S Cl2/S-200
0-2000   Cl2/C-2000    
0-5000   Cl2/C-5000  

 

Sensor Performance Characteristics(take Cl2/C-20 as an example)

Nominal Range 0 - 20 ppm
Maximum Overload 200 ppm
Expected Operation Life 2 years in air
Output Signal

- 900 ±250 nA/ppm

Resolution 0.1 ppm
Temperature Range - 40 °C to 50 °C
Pressure Range Atmospheric±10%
Pressure Coefficient No data
T90 Response Time < 60 sec
Relative Humidity Range 15 % to 90 % R.H. non-condensing

Typical Baseline Range (pure air, 20°C)

< 0.1 ppm

Maximum Zero Shift (+20°C to +40°C)

- 0.2 ppm
Long Term Output Drift < 2% signal loss/month
Recommended Load Resistor 10-33 Ohm
Bias Voltage Not allowed
Repeatability < 2 % of signal
Output Linearity

Linear

Sensor Physical Characteristics

Weight ~ 13 g
Position Sensitivity None
Storage Life Six months in container
Recommended Storage Temperature 5 °C - 20 °C
Warranty Period 12 months from date of dispatch

Module Parameters

Module type GM-I2(3)-M/C/S-**-****/G/P/F/FL
Detected gas Toxic gas
Detecting principle Electrochemistry
Sampling Diffusing  pump  flange  thread
Responding time 30s~40s(of the sensor)
Module accuracy ≤±3%FS(actual concentration, higher accuracy depends on specified sensors)
Module repeatability ≤±2% FS
Module linear error ≤±2% FS
Module zero temperature drift ≤±2% (FS/year)
Module operating temperature -40~80°C
Module humidity 0-95%RH(non-condensation)
Sensor operating temperature -20°C~50°C
Sensor humidity 0-90%RH(non-condensation)
Signal output TTL/4-20mA /RS485   (two or three wire)
Transmitting distance 1000 meters(RS485)
Operating voltage DC 12-36V
Maximum power ≤0.8W
Size 80*48mm
Explosion proof Intrinsic safe
Connection cable RVVP3 x 1.5mm²

Module applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control

Air Quality Chlorine Cl2 Gas Detector Sensor Disinfectant Toxic Electrochemical 1

Member Information

Advanced Sensors Application Technology Co., Ltd.
Country/Region:Guang Dong - China
Business Nature:Trading Company
Phone:18806643030
Contact:Daphne (Sales)
Last Online:06 Feb, 2018

Related Products of this Company