GDVA-405 CT PT Analyzer for Current Transformer and Potential Transformer

GDVA-405 CT PT Analyzer for Current Transformer and Potential Transformer
Model:GDVA-405
Brand:Gold
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Analysis Instrument
Label:Ct Pt Calibrator , Transformer Tester , Transformer Ct Pt
Price: US $100 / pc
Min. Order:1 pc
Inquire Now

Product Description

Application

Tests for Current Transformer:
1)Excitation curve and parameters test
2)Turns ratio test
3)Ratio and phase error test
4)Polarity mark check
5)Winding resistance measurement
6)Secondary loop burden measurement
7)Error line curve test for protection CT
8)Transient CT parameters test
9)CT nameplate guess
10) Saturation hysteresis loop curve measurement

Tests for Voltage Transformer:
1)Turns ratio test
2)Ratio error and phase angle error test
3)Polarity test
4)Secondary burden test
5)Winding resistance test


Applications of CT/PT Analyzer:
1)CT nameplate check
2)CT parameters check in work burden
3)CT transient parameters analysis
4)CT ratio and phase error calibration
5)PT routine test

Technical index

GDVA-405 Portable Fully Automatic CT PT Testing Equipment 

1)Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2)Power supply: AC220V±10%, 50/60Hz±10%
3)Voltage output: 0.1~180V (AC)
4)Current output: 0.001~5A(RMS)
5)Power output: 500VA
6)Maximum knee voltage measurement: 45KV
7)Current measurement:
   Range: 0~10A (automatically change range in 0.1/0.4/2/10A)
   Error: <±0.1%+0.01%FS
8)Voltage measurement:
   Range: 0~200V (automatically change range in 1V/10V/70V/200V)
   Error: < ±0.1%+0.01%FS
9)Turns ratio measurement:
   Range:1~35000
   1~2000 error<0.05% ;
   2000~5000 error<0.1% ;
   5000~35000 error<0.2%


10)Phase measurement: error: ±2min; resolution: 0.01min
11)Winding resistance measurement:
     Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
     Error: < 0.2%RDG+0.02%FS
     Maximum resolution: 0.1mΩ
12)Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree
13)CT Secondary burden:
     Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
     Error: <0.2%RDG+0.02%FS
     Maximum resolution: 0.001ohm 14) PT Secondary burden:
     Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) Error :<0.2%RDG+0.02%FS
     Maximum resolution: 0.1ohm 15) PT ratio measurement:
     Range: 1~35000 1~10000 error<0.1% 10000~35000 error<0.2%
16)PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%
17)PT phase angle measurement: maximum error < 3min
18)Make evaluation for test results according to selected standards
19)Make word report for test result
20)Make word reports one time for multi-group test records on the PC
21)Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test

22)Memory capacity:>5000groups

23)Work condition:Temperature:-10℃~50℃, moist:≤90%

24)Size:485mm×356mm×183mm

25)Weight:<15Kg

GDVA-405 CT PT Analyzer for Current Transformer and Potential Transformer 1GDVA-405 CT PT Analyzer for Current Transformer and Potential Transformer 2

Member Information

Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd.
Country/Region:Chong Qin - China
Business Nature:Manufacturer
Phone:18896024056
Contact:Heather (sales)
Last Online:26 Mar, 2018