MTS-100 Meter Test System

MTS-100 Meter Test System
Model:MTS-100
Brand:Kongter
Origin:-
Category:Electronics & Electricity / Other Electrical & Electronic
Label:meter test system , power meter test
Price: -
Min. Order:1 pc

Product Description

 

Phase: 3

Accuracy class: 0.05 or 0.1

AC voltage output: 0-792V

AC current output: 0-120A

This Meter Test System features state-of-art designing with high accuracy. It is composed of high accurate (class 0.05% or 0.1%) standard reference meter and power source (up to 120A). This system is particularly designed with modular structure for calibration and test of different single phase/3 phase electronic/inductive active and reactive energy meters.

 

 

Main function:

  1. Calibrate all kind of single/three phase electronic/inductive active and reactive energy meter;
  2. Automatically or single-step manually test basic error, creeping, starting, standard deviation of single/three phase energy meter, save user-defined calibrating scheme in Auto calibration;
  3. Support variables influence tests, such as: Voltage, frequency, harmonics, reverse phase sequence, Voltage unbalance, etc.
  4. Support special tests in energy meter type test, such as: phase triggering, pulse train triggering, etc. 
  5. Support DLT-645 communication protocolmulti-testing of  multifunction meter such as: demand indication error, demand cycle error, time slot switching error, energy error of different tariff period, etc.
  6. With OCXO, daily error of energy meter can be detected;
  7. Output 2nd ~63rd harmonics.

 

Main features:

  1. 8” color touch screen, interface friendly, easy to operate;
  2. Equipped with RS232, Ethernet, and WiFi interface, MTS-100 can either support stand-alone operation, PC control or handy wireless terminal control;
  3. Communicate with tested meters thru RS-485;
  4. Automatically calculate the error of meter, and the related data can be downloaded thru U-disk;
  5. Self-protection, alarming and displaying overload location for equipment output overload, Voltage short-circuit, Current open-circuit;
  6. Automatically detect, diagnose and alarm for failure.
  7. Remotely updating online, easily achieve software updating;
  8. Support calibration by user locally.

 

Order Info

MTS-100 contains 2 models with different accuracy below:

MTS-100C: Accuracy Class 0.05

MTS-100B: Accuracy Class  0.1

 

Technical Specification

AC Voltage output:

Range: 100V, 220V, 380V;

Adjusting range: (0~120) %RG, RG refers to range;

Adjusting resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG;

Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1);

Distortion: ≤0.2% (Non capacitive load);

Max output load: 20VA each phase;

Accuracy: 0.05%RG (Class 0.05), 0.1%RG (Class 0.1);

AC Current output:

Range: 0.05A, 0.2A, 1A, 5A, 20A, 100A;

Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter;

Adjusting resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG;

Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)

Distortion: ≤0.2% (Non capacitive load);

Max output load: 120VA (100A range)

Accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)

Power output

Power output stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)

Active/reactive power measurement accuracy: 0.05%RG;

Phase output

Output adjusting range: 0°~360°;

Output adjusting resolution: 10°, 1°, 0.1°, or 0.01°;

Resolution: 0.01°;

Measurement accuracy: 0.05°.

Power factor output:

Adjusting range: -1 ~ 0 ~ +1;

Measuring resolution: 0.0001;

Measurement accuracy: 0.0005

Frequency output

Adjusting range: 40Hz ~70Hz;

Output adjusting resolution: 1Hz, 0.1Hz, 0.01Hz, or 0.001Hz;

Resolution: 0.001Hz;

Accuracy: 0.002 Hz.

Harmonic setting

Harmonic order: 2nd ~63rd

Harmonic amplitude: 0~40%

Harmonic angle: 0°~359.99°

Harmonic set error: 2~31times: ≤±0.1%, 32~63 times: ≤±0.2%

Energy error measurement:

Active energy basic error limit:

±0.05%RD (Voltage 15V~660V, Current 0.02A~120A, PF≥0.5);

±0.1%RD (Voltage 15V~660V, Current 0.01A~0.02A, PF=1);

Reactive energy basic error limit:

±0.1%RD (Voltage 15V~660V, Current 0.02A~120A, PF≥0.5);

±0.2%RD (Voltage 15V~660V, Current 0.01A~0.02A, PF=1);

 

Energy pulse input

Input pulse: 3 channels active, 3 channels reactive

 

Other parameters:

Power supply:           90-265VAC/DC

Power frequency:        50Hz~60Hz

Power consumption:       50VA~1000VA

Environment condition:          20~30Humidity: RH≤85%

Storage environment:     -20~50

Size:                   600mmL× 440mmW× 266mmH

Weight:                    35kg

 

 

 

 

 

 

 

 

 

 

MTS-100 Meter Test System 1

Member Information

Kongter Test & Measurement Co., Limited
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:26805759
Contact:Diana Xu (Sales Manager)
Last Online:05 May, 2018