Max 90000 PSI Pressure Test Pump

 Max 90000 PSI Pressure Test Pump
Model:DGG SERIES
Brand:SUNCENTER
Origin:Made In China
Category:Industrial Supplies / Industrial Supplies Stocks
Label:[pneumatic hydraulic , air driven liquid pu , air hydro pump
Price: US $1000 / pc
Min. Order:1 pc
Inquire Now

Product Description

Product Details

Suncenter Max 90000 PSI Hydrostatic/Hydraulic/Hydro/Burst Pressure Test Pump

 

DGGD-2.jpg

Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal liquid pressure can be calculated.

 

Applications include:

· Pressure testing

· Burst(Hydrostatic) testing

· Work holding/power clamping

· Jacking/lifting

· Valve actuator control

· Hydraulic cylinder actuation

· Press safety overload devices

· Roller tensioning

· Metering

 

 

 

Key features include: 

·Compressed Air driven - no electricity required (connect to normal air compressor)

·In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

·No airline lubricator required 

·Pressures to 640Mpa (6400 bar)  

·Wide range of models with different ratios

·Built-in-cooling on most models 

·Easy to install, operate and maintain

·Best price / performance ratio 

·No heat, flame or spark risk and explosion proof 

·Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter pump will automatically start, keep the loop pressure constant

图片10.jpg

 

DGG Series Hydraulic Pressure Test Pump

Technical specification

Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet 
Pressure

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

3-8 bar

6XPL

48 bar

NPT1/2

NPT1/2

29.91

DGG10

10:1

3-8 bar

10XPL

80 bar

NPT1/2

NPT1/2

18.84

DGG16

16:1

3-8 bar

16XPL

128 bar

NPT1/2

NPT1/2

12.42

DGG28

28:1

3-8 bar

28XPL

224 bar

NPT1/2

NPT1/2

7.11

DGG40

40:1

3-8 bar

40XPL

320 bar

NPT1/2

NPT1/2

4.89

DGG64

64:1

3-8 bar

64XPL

512 bar

NPT1/2

NPT3/8

3.08

DGG80

80:1

3-8 bar

80XPL

640 bar

NPT1/2

NPT3/8

2.44

DGG100

100:1

3-8 bar

100XPL

800 bar

NPT1/2

NPT3/8

1.92

DGG130

130:1

3-8 bar

130XPL

1040 bar

NPT1/2

M14X1.5

1.47

DGG175

175:1

3-8 bar

175XPL

1400 bar

NPT3/8

M14X1.5

1.14

DGG255

255:1

3-8 bar

255XPL

2040 bar

NPT1/4

M14X1.5

0.75

DGG400

400:1

3-8 bar

400XPL

3200 bar

NPT1/4

M14X1.5

0.48

DGG510

510:1

3-8 bar

510XPL

4080 bar

NPT1/4

M14X1.5

0.65

DGG800

800:1

3-8 bar

800XPL

6400 bar

NPT1/4

M14X1.5

0.42

 

hydrostatic test pump

hydro test pump

pneumatic hydrostatic test pump

hydrostatic water test pump

hydrostatic test pump for sale

hydro test pump manufacturers

hydrostatic water pump

hydrotest pump price

hydro test pump suppliers

hydrostatic test pump prices

pneumatic hydrotest pump

hydro test pump for sale

hydro test pump price

hydrostatic pressure test pump

hydrostatic pressure pump

hydrostatic pressure test pump for sale

hydro pressure test pump

hydraulic test pump

hydraulic pump testing

portable hydrostatic test pump

 

Suncenter Max 6000 Bar Hydrostatic/Hydraulic/Hydro Pressure Test Pump For Hose/Pipe/Valve/Gauge/Cylinders

 

image.png

 

Suncenter DLS Series Pneumatic (Air driven) hydraulic pressure test bench 

SUNCENTER- Hydraulic test benches are compact and delicacy solution tailored to customer specific requirements with air driven liquid pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.

 

To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. SUNCENTER Hydraulic power packs are available with wide range of pressure ratios make these series of pumps ideal for powering a variety of oil/hydraulic operations. The maximum operating pressure up to 640 MPa. 

 

As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven liquid pump have to be equipped with the air control unit combined filter and water separator, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel. 

 

The desired operating pressure can be attained by adjusting the driving air pressure. When the driving air pressure and the output pressure reach the balance, the pump stops filling pressure and the output pressure stays at the preset value. This hydraulic unit can be used for all kinds of pressure testing and test tools for research and test institutes or for other functions requiring a determined pressure.  

 

 

DLS-G Sereis hydraulic pressure test bench-The hottest selling Model C cabinet

The standard hydraulic test bench/stand including following parts:

Air –driven liquid booster pump

Stainless steel material cabinet (Three models for choosing)

F.R.L combination for driven air (adjusts air pressure, add lubricating oil and filter)

Driven air switch (Pump starting switch), driven air pressure gauge, water tank

Liquid inlet/outlet switch, high pressure liquid guage, unloading valve, interconnecting pipes etc.

And we could also customize it according to clients’ special requirement.

 

image.png

 

DLS-DGG series hydraulic pump test bench Technical specification

Model

Pressure

Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet 
Pressure(bar)*

Driven 
 air inlet port

High pressure Outlet port

MAX Flow 
(L/min)**

DLS-GD4

4:1

3-8 bar

4XPL

32

G 1/2

NPT/ZG

70.0

DLS-G6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

29.91

DLS-G10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

18.84

DLS-G16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DLS-G28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DLS-G40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

4.89

DLS-G64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

3.08

DLS-G80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

2.44

DLS-G100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

1.92

DLS-G130

130:1

3-8 bar

130XPL

1040

G 1/2

NPT/ZG

1.47

DLS-G175

175:1

3-8 bar

175XPL

1400

G 1/2

NPT/ZG

1.14

DLS-G255

255:1

3-8 bar

255XPL

2040

G 1/2

NPT/ZG

0.75

DLS-G400

400:1

3-8 bar

400XPL

3200

G 1/2

NPT/ZG

0.48

DLS-G510

510:1

3-8 bar

510XPL

4080

G 1/2

NPT/ZG

0.65

DLS-G800

800:1

3-8 bar

800XPL

6400

G 1/2

NPT/ZG

0.42

Should the hydraulic pressure test bench caters to your requirement, welcome to buy the equipment with our factory. Well-known as one of the professional manufacturers and suppliers, we're equipped with a productive factory to produce the best quality equipment for you.

                 

 Max 90000 PSI Pressure Test Pump 1

Member Information

SUNCENTER FLUID CONTROL EQUIPMENT CO.,LTD
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:15812870862
Contact:Rose Zhang (overseas sales)
Last Online:05 Jun, 2018