Model: | MCA-1200 |
---|---|
Brand: | CREATEC |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Analysis Instrument |
Label: | Free chlorine , Toal chlorine , residual chlorine |
Price: |
¥18000
/ pc
|
Min. Order: | 1 pc |
Hebei Create Instrumentation Technologies Co., Ltd. are the leading supplier of water quality instrumentations with history of 25 years.
Our production line covers :
- Reverse Osmosis Controller.
- Conductivity/ Resistivity Meters & Transmitters.
- pH /ORP Meters & Transmitters.
- Flow Meter and Sensors.
-Optical Dissolved oxygen controller
-COD and BOD analyzer
-Ammonia Nitrigen analyzer
- Free Chlorine Systems.
-Turbidity Analyzers.
-Online multi-parameter system integration DCS-8600 (customization one)
-EDI Module for the ultra pure water product
-Hardness
-Dosing pumps
-Ozone analyzer
Series Chlorine analyzer (DPD method) measure at 0.01 ~0.05 mg/L, Better than the sensor type Chlorine analyzer.
1. Integrated sensor to measure floor type cabinet,MCA-1201(HCIO)free chlorine online analyzer(DPD method three kinds of reagents)
1.1. System Specification
Summary |
||
Display screen |
7 inch colour touch screen |
|
Dimension |
730(H)*500(W)*280mm(D) |
|
Weight |
About 20kg(excluding reagent) |
|
Installation |
Wall type or bracket |
|
Sample requirements |
||
Influent flow range |
300-1200 mL/min |
|
Sample temperature range |
0-40℃ |
|
Sample pipeline |
The instrument is equipped with 5 meters of 1/4 "PE fine plastic pipe, connecting inlet 1/4" fast partition joint. |
|
Drainage pipeline |
The instrument is equipped with 2 meters of 3/8"PE pipe, connecting inlet 3/8" fast partition joint. |
|
Reagent |
||
Reagent container |
3*500mL thick plastic reagent bottle |
|
Reagent installation |
The reagent bottle is fixed on the reagent rack, lack reagent alarm will remind with remaining 20% reagent. |
|
Electrical Specifications |
||
Power supply |
220V AC, 50/60 Hz |
|
Power connection |
The power cord with 3 cores and plugs is connected to the mains socket with ground |
|
Leakage protection |
IC65N 10A/2P 30mA AC220V |
|
Data output |
RS485 serial communication; |
|
Instrument performance |
||
Measuring method |
N,N-diethyl-1,4-phenylenediamine(DPD)spectrophotometry(GB 11898-89) |
|
Measurement range |
0-1mg/L ,1-5mg/L |
|
Accuracy |
0-1.0mg/L:± 0.05mg/L in Cl2; 1.0-5.00mg/L:relative error±5% in Cl2 |
|
Measurement period |
5min/time |
|
Measurement interval |
1-999 minutes interval can be set, or hourly measurement can be selected. |
|
Lower limit |
0.005mg/L |
|
Instrument calibration |
Zero point calibration, the slope calibration |
|
Environment |
||
Storage temperature range |
Temperature:-10-50℃(No Condensation) |
|
Range of application |
Temperature: 0-40℃,no icing |
|
Relative environment humidity |
Relative humidity:≤85%RH(noncondensable) |
Hebei Create Instrumentation Technologies Co., Ltd
Add:A.1st Floor ,NO.2 Building ,No.368 North Xinshi Road,
Shijiazhuang 050091,Hebei Province,China.
Contact:Ms Liceya Skype:liceya.create
Tel: 86-311-83831058
Liceya(at)createc.cn Wechat : liceya_wang
Hebei Create Instrumentation Technologies Co., Ltd | |
---|---|
Country/Region: | He Bei - China |
Business Nature: | Manufacturer |
Phone: | 83056196-860 |
Contact: | Liceya wang (Sales director) |
Last Online: | 08 Jun, 2015 |