Model: | TeSys D |
---|---|
Brand: | Schneider |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Components / Relay & Contactor |
Label: | Schneider , TeSys D , LC1D12BL |
Price: |
US $1
/ pc
|
Min. Order: | 50 pc |
Main
Range | TeSys |
Product name | TeSys D |
Product or component type | Contactor |
Device short name | LC1D |
Contactor application | Motor control
Resistive load |
Utilisation category | AC-3
AC-1 AC-4 |
Poles description | 3P |
Pole contact composition | 3 NO |
[Ue] rated operational voltage | <= 300 V DC for power circuit
<= 690 V AC 25...400 Hz for power circuit |
[Ie] rated operational current | 12 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit |
Motor power kW | 7.5 kW at 500 V AC 50/60 Hz AC-3
7.5 kW at 660...690 V AC 50/60 Hz AC-3 5.5 kW at 380...400 V AC 50/60 Hz AC-3 5.5 kW at 415...440 V AC 50/60 Hz AC-3 3 kW at 220...230 V AC 50/60 Hz AC-3 3.7 kW at 400 V AC 50/60 Hz AC-4 |
Motor power hp | 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors
3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors |
Control circuit type | DC low consumption |
[Uc] control circuit voltage | 24 V DC |
Auxiliary contact composition | 1 NO + 1 NC |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
Overvoltage category | III |
[Ith] conventional free air thermal current | 25 A at <= 60 °C for power circuit
10 A at <= 60 °C for signalling circuit |
Irms rated making capacity | 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 105 A <= 40 °C 10 s power circuit
210 A <= 40 °C 1 s power circuit 30 A <= 40 °C 10 min power circuit 61 A <= 40 °C 1 min power circuit 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit |
Associated fuse rating | 25 A gG at <= 690 V coordination type 2 for power circuit
40 A gG at <= 690 V coordination type 1 for power circuit 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
Average impedance | 2.5 mOhm at 50 Hz - Ith 25 A for power circuit |
[Ui] rated insulation voltage | 600 V for power circuit certifications CSA
600 V for power circuit certifications UL 690 V for power circuit conforming to IEC 60947-4-1 690 V for signalling circuit conforming to IEC 60947-1 600 V for signalling circuit certifications CSA 600 V for signalling circuit certifications UL |
Electrical durability | 2 Mcycles 12 A AC-3 at Ue <= 440 V
0.8 Mcycles 25 A AC-1 at Ue <= 440 V |
Power dissipation per pole | 0.36 W AC-3
1.56 W AC-1 |
Protective cover | With |
Mounting support | Rail
Plate |
Standards | CSA C22.2 No 14
EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
Product certifications | CCC
UL RINA CSA GOST GL BV LROS (Lloyds register of shipping) DNV |
Connections - terminals | Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable
end Power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end Power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end Power circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end Power circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end Power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end Power circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end |
Tightening torque | Power circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 |
Operating time | 65.45...88.55 ms closing
20...30 ms opening |
Safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Mechanical durability | 30 Mcycles |
Operating rate | 3600 cyc/h at <= 60 °C |
If you need more detailed parameter,
pls feel free contact us at:
Skype: shu.vicky2
Our Company website: http://www.BMingPower.com
Payment Terms: | TT |
---|---|
Shenzhen BM Tech Co., Ltd | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Trading Company |
Phone: | 18128556097 |
Contact: | Happy Yuan (sale) |
Last Online: | 20 Jun, 2019 |