K type thermocouple with connector

K type thermocouple with connector
Model:WRKK1-007EA-100
Brand:Duchin
Origin:Made In China
Category:Electronics & Electricity / Electric Control System
Label:K type thermocouple , Thermocouple sensor , Thermocouple plug
Price: US $15 / pc
Min. Order:1 pc
Inquire Now

Product Description

For Base Metal thermocouple, type k thermocouple is the most commonly used at all, including K,N,E,J,T types, can be assembly and sheath structures. The highest accuracy is ±1.5℃,and the highest using temperature is 1300℃(K,N);For T type, the highest accuracy is ±0.5℃,the highest using temperature is 350℃. The temperature is mainly applied for oxide environment, and widely measures kinds of industry production process which temperature below 1300℃.

 

Conductor 
material

Calibration

Accuracy

ClassⅠ

ClassⅡ

Accuracy

Temperature range( °C )

Accuracy

Temperature range( °C )

NiCr-NiSi

K

±1.5°C 
or 
±0.4%|t|

-40-1000

±2.5°C 
or 
±0.75%|t|

-40-1000

NiCr Si-NiSi

N

-40-1100

-40-1200

NiCr-Konstantan

E

-40-800

-40-800

Fe-Konstantan

J

-40-750

-40-750

Cu-Konstantan

T

±0.5°C or 
±0.4%|t|

-40-350

±1°C or 
0.75%|t|

-40-350

PtRh10-Pt

S

±1°C or 
±[1+ ( t-1100 ) × 0.003]

0-1600

±1.5°C 
or 
±0.25%|t|

0-1400

PtRh13-Pt

R

0-1600

PtRh30-PtRh6

B

——

——

600-1700

 

About protection tube material

The protection tube material always be SUS304,when the using environment with chemical corrosion, should consider SUS316L tube;for strong corrosion environment,such as with H2SO4,HNO3,H2S,should consider Ta tube.

For oxide environment temperature above 900℃,always use 2520(310S),when higher than 1000℃,always consider GH3039,Inconel600 and 99% Al2O3 protection tube. When temperature up to 1200℃,just 99% Al2O3 tube have to be considered.

 

About Process connection

For non-sealing environment, the thermocouple can be without thread or flange. For sealing environment, have to with thread or flange. The process connection is depended on your device.

 

About wire connection device

The goal of wire connection device is convenient and reliable. When not use connection head,the ways can be ceramic block with wire leads, cross sleeve with wire leads, spring cross sleeve with wire leads,etc.,When use connection heads, can be with water-proof head, d IIBT4 explosion-proof head, d IICT6 explosion-proof head, explosion-proof head with local display,multi points connection head.

Payment Terms:T/T,West Union
K type thermocouple with connector 1K type thermocouple with connector 2

Member Information

Chongqing Duchin Instrument CO.,LTD
Country/Region:Chong Qin - China
Business Nature:Manufacturer
Phone:15123271461
Contact:Emily (Sales)
Last Online:15 Jul, 2019