New Product Lab Testing Particle Size Analysis Equipment for Powder Gas

New Product Lab Testing Particle Size Analysis Equipment for Powder Gas
Model:Winner2009B
Brand:Winner
Origin:Made In China
Category:Chemicals / Chemical Lab Supplies
Label:Winner2009
Price: US $19000 / pc
Min. Order:1 pc
Inquire Now

Product Description

New Product Lab Testing Particle Size Analysis Equipment

for Powder Gas Winner2009B

 2009.jpg

Brief Introduction:

 

Winner2009 full automatic wet laser particle size analyzer measure size is for Large Range  Range from Namometer to millimeter. 

It use dual beam& multi spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, 

on behalf of the domestic advanced level in the field. It could be used to measure size of all  Non-metallic mineral materials.

   

Specifications: 

 

Model Name

Winner2009A

Winner2009B

Standard

ISO13320:2009, GB/T19077-2016, Q/0100JWN001-2013

Measuring Range

0.01-2000μm

0.01-1200μm

Channels Number

127

120

Accuracy  error

<0.5%   (Deviation of  D50 on national standard sample)

Repeatability error

<0.5%   (Deviation of  D50 on national standard sample )

Light source

Main: He-Ne laser (λ= 632.8nm,  P>2.0MW)

Auxiliary: Semiconductor laser:λ= 405nm,  P>2.0MW

Sample Pool

Volume:1L

Ultrasonic

Frequency:40KHz   Power: 60W 

Stir

Revolutions Speed: 0-3000RPM (Adjustable)

Circulate

Rated Flow:30L/min    Rated Power:70W

Operation Mode

Full automatic software control

Optical Calibration System

Full automatic

Test Speed

<2mins for each time

Volume

L119cm×W38cm×H56cm AND L44.2cm×W28cm×H34.2cm 

Dry and Wet Equipment Independently

Net Weight

73Kg

 

Main Features:

 

1)Winner Patent -Optical path design

Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Double spectrum design make its precision achieves from 0.01um to 2000μm,and Dual-laser orthogonal light make use of the semiconductor auxiliary laser extend the test angle from 45 degree to 135 degree, ensure receive all the angles of signals. 

 

2) Expand Size Range

 Winner2009A measurement range significantly expanded to 0.01um, particularly suitable for small samples of the user, the sub micron particle test results reached the international level

 

 3)Full built-in dispersion system

The ultrasonic dispersion, mechanical stirring and circulation channel reasonable integrated in the interior of the instruments, ensure  the uniform dispersion and distribution of particles in the testing process, effectively avoid uneven distribution, large particle deposition phenomenon caused by long pipe line of outside dispersion system , to ensure the accuracy of the test results.

 

4)Intelligent Operation mode

 With intelligent automatic mode of operation, to achieve a key test, as long as according to the prompt addition of sample, click the "test", all processes including water-supply, dispersion, circulation, testing, cleaning, data record, data analysis, save and print are automatically completed, not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.

 

5)Automatic Optical path alignment system

 

The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.1um, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.

 

 

6)Authoritative calibration method

 In the entire test range using the national standard materials for calibration, only a year calibration once the instrument can. Calibration method is simple and quick.

 

7) Unconstrained free fitting technique

 

Winner original unconstrained free fitting technology, particle size analysis is not affected by any functional constraints, can be a true reflection of the distribution of particles.

  

 

Output parameters: particle size, particle distribution etc. D10, D 50,  D 90 and other customized parameters.

International Accuracy: <1% reference to D50 value of standard sample.

Repeatability:<1% reference to D50 value of standard sample.

 

$E[9{1L4LP03D4S5EWCJA5_

  

Packaging & Shipping

 

Wooden box package, G.W.:40KG.

We would ship machine by DHL, FeDex, China express, by sea and by air. 

 photobank (3).jpg

 

Our Services

 

After sale service 


1. We will send our technician to install instruments.( operation demo video CD will be offered also.) 
2. Offer free-training service. 
3. The quality assurance date is 2 years since finishing payment, Technology support in all a life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected). 
5. We offer the components with favorable price and perdurable maintenance. 

 

 rtifications

Certifications

 

Patent Technology:

 

 

  1. Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
  2. 3 dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
  3. Mie scattering principle application patent No.- ZL 2013 2 0812021.4.
  4. Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0
  5. Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2

 

 

12

 

 

Company Information

 

JINAN WINNER PARTICLE INSTRUMENT STOCK CO., LTD. have been specialized in laser particle size analyzer since 1985, Our General Manger, Professor Ren created 1st of laser paraticle size analyzer in Jinan University,  We are specialized in Laser DiffractionParticle Size Analyzer, Dynamic Light Scattering Nanometer Particle Size Analyzer,Image Particle Size Analyzer, OnlineParticle Size Analyzer,Droplet Particle Size Analyzer and Particle Counter etc.

 

Winner particle size 9.jpg

Laser particle size analyzer

Winner particle size 10

FAQ

 1. How about the package ? Is it safe during the delivery ? 

All Particle size analyzer is packed by standard strong wooden carton with foam inside.

It is safe when shipping. 

 

2. What is the delivery way ? How many days will the machine 

We will ship the particle size analyzer by DHL,FedEx, UPS,etc (Door to Door Service), around 5 days to arrive.

Or by Air to your airport (Door to Airport Service ), around 3 days to arrive. 

Or by Sea to the seaport,  Minium CBM requirement : 1 CBM, around 30days to arrive.

 

3. Do you provide the Warranty ? How about the after sales service ?

2 year warranty free for spare parts, Whole life technical support.

We have professional after sales team, if any question, assistant videos are also provided in after-sale service.

 

4, This machine is easy to use ? if I have no experience, I can also operate it well ?

Do you provide the user manual and operating videos to support us ?

Yes, our particle size analyzer is designed to use easily, computer control. Normally it will take you 2-3 hours to learn how to operate, if you are a technician, it will much faster to learn.

We will provide the English user manual for free , and the operation video is available.

 

5, If we come to your factory, if you will provide the free training ?

Yes, warmly welcome you to visit our factory, we will arrange the free training for you.

 

6. What is the payment way ?

We accept the payment terms: Bank transfer, Western union, Money gram, Paypal, etc.

 

If any question, you can send INQUIRY , or CHAT with us, we will be glad to service you !

 

CE Certificate : 

photobank_.png

 

Please Contact Us 

Shirely Yang Contact

 

 

 

New Product Lab Testing Particle Size Analysis Equipment for Powder Gas  1New Product Lab Testing Particle Size Analysis Equipment for Powder Gas  2

Member Information

Jinan Winner Particle Instrument Stock Co., Ltd.
Country/Region:Shan Dong - China
Business Nature:Manufacturer
Phone:13356662781
Contact:Shirely Yang (Sales)
Last Online:20 Aug, 2019