Model: | - |
---|---|
Brand: | DIJIA |
Origin: | Made In China |
Category: | Chemicals / Inorganic Chemical Materials / Inorganic Salt |
Label: | Hydrogen Chloride , HCL gas , gas |
Price: |
US $2
/ pc
|
Min. Order: | 1 pc |
Quick Details
Classification:Hydrochloric Acid
CAS No.:7647-01-0
Other Names: muriatic acid
MF:HCL
EINECS No.:231-595-7
Place of Origin:Shandong, China (Mainland)
Grade Standard:Agriculture Grade, Food Grade, Medicine Grade, Reagent Grade
Purity:99.9
Appearance:gases
Application:dye
Brand Name:yanhe
Model Number:lc-054
Packaging Details:cylinders
Color:colorless
UN NO:1050
Usage:industrial
Size:44L
Experiences:29 years
Quality:Prime
Form:gas
Certificate:SGS MSDS COA
HS Code:2806100000
Packaging & Delivery
Selling Units:
Single item
Single package size:
11X11X11 cm
Single gross weight:
79.0 kg
Package Type:
GAS CYLINDER
Lead Time :
Parameter
Hydrogen Chloride Physical Constant
<table ke-zeroborder"="" border="0" cellspacing="0" style="border: 0px none; border-collapse: collapse; margin: 2px; min-width: 400px; text-align: center; font-family: "sans serif", tahoma, verdana, helvetica; width: 384pt;">
Quantity(Set) |
1 - 1 |
2 - 20 |
21 - 50 |
>50 |
Est. Time(days) |
20 |
30 |
45 |
to be negotiated |
Molecular Formula |
: HCL |
Molar Volume |
: 22.25L |
|
Molecular Weight |
: 36.46 |
Gas Viscosity Measurement (20) |
: 1.56c/o 10-5Pa S |
|
Gas Specific Weight (0, Air=1) |
: 1.268 |
Constant-pressure Specific Heat(15,0.1MPa) |
: Cp=0.812Kj/Kg K |
|
Specific Gravity Hydrometer(10, Water=1) |
: 0.88 |
Constant-volume Specific Heat(15,0.1MPa) |
: Cv=0.576Kj/Kg K |
|
Critical Pressure |
: 8.258MPa |
1L Liquid(10)= |
540L Gas |
|
Critical Temperature |
: 51.4 |
1Kg Liquid= |
613L Gas |
|
Critical Density |
: 0.424g/cm3 |
Latent Heat of Melting |
: 54.80Kj/Kg |
|
Latent heat of Evaporation |
: 443.3Kj/Kg |
Atmospheric Boiling Point |
: -85 |
|
Gas Density(0,0.1MPa) |
: 1.639g/dm3 |
(21,0.1MPa) |
: 1.522g/dm3 |
Liquid hydrogen chloride vapor pressure:
Temperature () |
-85.03 |
-10 |
0 |
10 |
20 |
30 |
40 |
Pressure (Mpa) |
0.1 |
1.96 |
2.57 |
3.32 |
4.21 |
5.27 |
6.53 |
Density (g/cm3) |
1.191 |
0.962 |
0.924 |
0.881 |
0.831 |
0.772 |
0.697 |
Physical & Chemical Properties
Colorless, toxic, irritating, smothering, non-flammable gas: strong hygroscopic, after absorbing the moisture in the air, hydrochloric acid is generated, with strong corrosiveness.
Stored in cylinders in the form of liquefied gas, pressure (3-6MPa) is constant, and its value is related to temperature.Inorganic compounds such as tin chloride, phosphorus trioxide, phosphorus bromide, and so on, and organic compounds such as paraffin, ethanol, ether, acetaldehyde, ketone, acid, ester, nitrite, cyano, etc. Can be dissolved well in hydrogen chloride, and additional reaction can occur.
Pure liquid hydrogen chloride does not react with most metals. however, it reacts with alkali metals, aluminum, manganese, iron, copper, tin, lead and zinc and produces a protective film of chloride on its surface. When water is present, it reacts with metal to form metal chloride and hydrogen gas.
HAZARDS IDENTIFICATION
Classification of the substance or mixture
Gas under Pressure (Liquefied gas).
Acute toxicity(inhalation) Category 3
Skin corrosion/irritation Category 1A
GHS Label elements, including precautionary statements
Signal word: Danger
Hazard statement(s): Contains gas under pressure; may explode if heated. Toxic if inhaled. Causes severe skin burns and eye damage.
Precautionary statement(s):
Prevention: Avoid breathing dust/fume/gas/mist/ vapors/spray. Use only outdoors or in a well-ventilated area. Wash thoroughly after handling. Wear protective gloves/protective clothing/eye protection/face protection.
Response: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor. Specific treatment (see next). IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. Wash contaminated clothing before reuse. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor.
Storage:Protect from sunlight. Store in well-ventilated place. Keep container tightly closed. Store locked up.
Disposal: Dispose of contents/container to relevant regulations.
Description of necessary first aid measures
If inhaled: If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
in case of skin contact: Wash off with soap and plenty of water.
in case of eye contact: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed: Not considered a normal route of entry.
Use & Storage
the storage room for hydrogen chloride cylinder should be ventilated and dry, avoid direct sunlight, and there should be no underground trenches or secret passages. Open fire is strictly forbidden and away from heat source.
Cylinder should be placed vertically, with the cap, properly fixed, prevent dumping.
When using, connect the exhaust nozzle of the cylinder valve with the production device. Gas leakage is strictly prohibited.
When used, the ambient temperature is between -20 degrees Celsius and 40 degrees Celsius
Avoid sun exposure and stay at least 10 meters away from an open flame.
the gas in the bottle shall not be used up, and the pressure shall be kept at not less than 0.5mpa.
for the intermittent system, the air of the high-purity nitrogen replacement system should be used first, and then the hydrogen chloride should be used to enter the system and discharge nitrogen, so that the system can carry out normal production. after production, hydrogen chloride in the high purity nitrogen replacement system is used to prevent system corrosion. after use, close the cylinder valve in time, remove the cylinder from the system, wipe each part of the cylinder valve, and tighten the bottle cap.
the use of self - contained cylinders, the valves must be changed by us. If the bottle valve is damaged, please ask our company to replace it.
Special cylinder for hydrogen chloride is strictly prohibited to refit other gases.
Cylinder body and valve are strictly prohibited oil pollution.
in the process of use, when the gas cylinder exhaust speed is relatively fast, the cylinder and pipeline crystallization is normal, and it is forbidden to be poured with hot water. In order to avoid frost in cylinder and pipeline, please use special gas supply device when the flow rate of gas consumption is greater than 2m3/h. We can provide special air supply equipment.
When the reliability of the cylinder cannot be determined, it should be tested immediately. the cylinder safety inspection period is two years, and the cylinder beyond the safety inspection period cannot be used.
the cylinder should be sent to us for maintenance after one year of use
the user unit shall organize workers and relevant management personnel to study the technical specification of hydrogen chloride safety, and be familiar with the accident hazards that may occur with hydrogen chloride gas and other relevant knowledge and information such as first aid and emergency measures.
Chemical Hydrogen Chloride 2.8N
Level: Chemistry 2.8N |
PURITY/%: 99.8% |
Packing: 40L/44L |
Enterprise number: LC054 |
Weight: 25Kg/27Kg |
Pressure: 4.2 Mpa (20) |
Valve: CGA330- 316LDiaphragm Valve |
|
Composition |
Product specification |
Inspection Equipment |
Limit |
Impurity 1*10-6(v/v) |
Nitrogen |
<= 85 |
Heat Ion Chromatograph |
5.00 |
Oxygen + Argon |
<=10 |
Heat Ion Chromatograph |
5.00 |
|
Hydrocarbon |
<=1900 |
Hydrogen flame ionization detector |
0.10 |
|
Water |
<=5 |
Online Micro Water Analyzer |
0.10 |
|
Dew point/ |
|
<-66 |
Photoelectric Dew Point Meter |
-84 |
Synthesis of fine chemicals such as pesticide intermediates, dye intermediates, catalysts, chemical auxiliaries and additive
Regulations:
this safety data sheet is in compliance with the following national standards: GB16483-2008, GB13690-2009, GB18218-2009, GB15258-2009, GB6944-2012, GB190-2009, GB191-2009, GB12268-2008, GA57-1993,
GB/T 15098-2008, GBZ 2-2007 as well as the following national regulations: Dangerous Goods Transport Administrative Regulation, Dangerous Chemicals Safety Administrative Regulation.
FAQ:
1. What is hydrogen chloride?
the aqueous solution of hydrogen chloride (HCl) is called hydrochloric acid.
2. What are the areas where hydrogen chloride is used?
Battery, medicine, dyestuff, fertilizer, glass processing, metal cleaning, organic synthesis, corrosion photography, pottery manufacturing, food processing, inorganic chloride manufacturing, rubber, catalyst, electronic gas, standard gas, epitaxy, diffusion, oxidation, etching, chemical gas deposition, light-emitting diode, etc.
3. Why choose to cooperate with "Yanhe"?
Focus on the development and manufacture of hydrogen chloride gas for over 29 years, we are the preferred supplier for many dealers.
4. Can I become an agent?
Yes, of course. Details require more communication.
Zibo Dijia Special Gas Co., Ltd. | |
---|---|
Country/Region: | Shan Dong - China |
Business Nature: | Manufacturer |
Phone: | 18966258719 |
Contact: | FAN (manager) |
Last Online: | 28 Aug, 2019 |