Gas Chromatograph

Gas Chromatograph
Model:GC-7860
Brand:Yoke Instrument
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Analysis Instrument
Label:gas chromatograph , gc , chromatograph
Price: -
Min. Order:1 pc

Product Description

GC-7860 Series Gas Chromatograph

 

GC-7860 A/SA gas chromatography use electronic gas circuit EPC/EFC control mode, advanced electronic gas circuit control (EPC/EFC) system, can provide industry users with industry-leading excellent quality and reliable results. The instrument has a unique network remote transmission and control function, so that the instrument in unattended, decentralized detection, centralized control into a reality; Data analysis results can be connected to DCS to complete the statistics, analysis and monitoring of chromatographic component content and improve the automation of the production process.

 

GC-7860 series gas chromatography is widely used in petrochemical, fine chemical, biological medicine, environmental protection, food hygiene, high purity gas, electricity, wine making, scientific research and education and other fields.


GC-7860 series network-based gas chromatography can be configured with 6-bit, 15-bit, and 150-bit liquid automatic samplers, and each parameter can be controlled by the reverse control software, which will bring better repeatability and improve work efficiency, while eliminating errors caused by manual samplers.
 

Features:

  • 5.7-inch dot-matrix LCD large liquid display, support Chinese and English switch.
  • Full electronic gas circuit (EPC/EFC) control mode, networking communication (Ethernet interface IEEE802.3), computer online full control operation.

3. SA series (component no. GS46), 1/16in imported stainless steel pipeline and stainless steel connector; The sample inlet and the vaporization chamber of the detector are specially treated to minimize the dead volume of the sample and the adsorption of the tube wall on the sample. With electronic gas circuit EPC/EFC, easy to operate.

4. Electronic gas circuit (EPC/EFC) control mode (A/SA)

a. EPC electronic gas circuit control precision is 0.01mL/min or 0.01Kpa, which ensures better retention time reproducibility and more consistent and reliable results

b. EPC working mode: constant current, constant voltage, shunt mode

Program pressure control: 4 stage

c. EPC working gases: N2, H2, Air, He, Ar

d. EPC control range: pressure 0~ 0.6kpa flow 0~100sccm or 0~500sccm

e. EPC control accuracy: pressure 0.01Kpa; Flow rate of 0.01 sccm

  • Could be up to 450 ℃, suitable for high boiling point the analysis of the sample
  • Support double oven and double rear door opening mode
  • Oven temperature increment 1 ℃, the accuracy of + / - 0.01 ℃, is close to high-grade imported similar products
  • External events: 6-way. auxiliary control 2-way.
  • Diversified injection system; Packed column injection, capillary S/SL injection, valve injection, automatic liquid injection, automatic headspace injection, splitting injection, thermal desorption injection, purge and capture injection are optional
  • Special customized valve system can help users complete complex multidimensional chromatographic analysis tasks. Plus series is a multi-purpose gas chromatography specially designed for multidimensional application analysis and online analysis.
  • Rich detector types, up to three detectors can be installed: TCD, HTCD, uTCD, FID, FPD, ECD, NPD, ZD, PDHID, PID, AID
  • The program supports multiple flow path sample selection MPV system, with automatic identification valve number, automatic cascade judgment, automatic reset, valve position selection, valve position analysis memory function, up to 32 support sample flow path selection
  • Unique network remote transmission and control functions, unattended analysis, decentralized monitoring, centralized control.
  • The data can be connected to DCS system to complete the statistics, analysis and monitoring of chromatographic component content and improve the automation level of production process control
  • Temperature control index
  • Temperature control circuit number: 8
  • Oven temperature index

Oven temperature range: room temperature of 4 ℃ ~ 450 ℃ (increment 1 ℃)

Oven temperature control precision, better than ±0.01 ℃

Oven temperature programming Rising order: 16 order

Rising rate setting: 0.1 ~ 39 ℃ / min (ordinary type); 0.1~80℃/min (high-speed type)

Constant temperature time of each order: 0~999min (increment: 0.1min)

Programmed cooling: 260 ℃ to 50 ℃ only need 6 minutes

  • Sample injector, detector, thermal conductivity pool, methane reformer temperature index:

Range of temperature: Room temperature of 4 ℃ ~ 450 ℃ (increment 1 ℃)

The accuracy of temperature control: better than±0.01 ℃

 

Gas Chromatograph 1Gas Chromatograph 2

Member Information

Shanghai Yoke Instrument Co., Ltd.
Country/Region:Shang Hai - China
Business Nature:Manufacturer
Phone:13910582189
Contact:Ellie Zheng (Sales Manager)
Last Online:16 Jan, 2020

Related Products of this Company