Accu-Tell® HCV Rapid Test Cassette

Accu-Tell® HCV Rapid Test Cassette
Model:-
Brand:-
Origin:Made In China
Category:Chemicals / Other Chemicals
Label:Testing Instrument , Rapid Test , Drug of abuse test
Price: -
Min. Order:500 pc

Product Description

Accu-Tell® HCV Rapid Test Cassette/Strip (Whole Blood/Serum/Plasma)

HIV Rapid Test Supplier

ACCU-TELL® HCV Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibody to Hepatitis C Virus in whole blood, serum or plasma. For professional in vitro diagnostic use only.

CATALOG

Product Name

Specimen

Catalog No.

Quantity per box

Certificate

HCV Strip

Whole Blood/Serum/Plasma

ABT-IDT-A12

100T;50T

 

HCV Cassette

Whole Blood/Serum/Plasma

ABT-IDT-B12

50T;20T

 

 

KEY POINTS

Detection for: antibody to Hepatitis C Virus in whole blood, serum or plasma;

Specimen volume: Serum or Plasma specimen: 25 μL, or

                                 Venipuncture Whole Blood specimen: 50 μL, or

                                 Fingerstick Whole Blood specimen: 50 μL

Reading time: 10 minutes;

Relative sensitivity: 100.0% (95%CI*: 99.3%~100.0%);  

Relative specificity: 99.8% (95%CI*: 99.4%~100%);

Accuracy: 99.9% (95%CI*:99.6%~100.0%).     

*Confidence Intervals

 

INTRODUCTION of Dengue Rapid Test

Hepatitis C Virus (HCV) is a small, enveloped, positive-sense, single-stranded RNA virus. HCV is now known to be the major cause of parenterally transmitted non-A, non-B hepatitis. Antibody to HCV is found in over 80% of patients with well-documented non-A, non-B hepatitis.

 

INTENDED USE

ACCU-TELL® HCV Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibody to Hepatitis C Virus in whole blood, serum or plasma.

For professional in vitro diagnostic use only.

 

TEST PROCEDURE

For Cassette

Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.

1. Place the cassette on a clean and level surface.

2. For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25 μL) to the specimen area, then add 2 drops of buffer (approximately 80 μL),and start the timer, see illustration below.

For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50 μL) to the specimen area, then add 2 drops of buffer (approximately 80 μL), and start the timer. See illustration below.

For Fingerstick Whole Blood specimen:

To use a capillary tube: Fill the capillary tube and transfer approximately 50 μL of fingerstick whole blood specimen to the specimen area of test cassette, then add 2 drops of buffer (approximately 80 μL) and start the timer. See illustration below.

3. Wait for the colored line(s) to appear. The test result should be read at 10 minutes. Do not interpret the result after 20 minutes.

We are Hepatitis b Rapid Test Wholesaler.

For Strip:

Bring the pouch to room temperature before opening it. Remove the test Strip from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.

1. Place the Strip on a clean and level surface.

2. For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25μL) to the specimen area,then add 2 drops of buffer (approximately 120 μL),and start the timer, see illustration below.

For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50μL) to the specimen area, then add 2 drops of buffer (approximately 120μL), and start the timer. See illustration below.

For Fingerstick Whole Blood specimen:

To use a capillary tube: Fill the capillary tube and transfer approximately 50μL of fingerstick whole blood specimen to the specimen area of test strip, then add 2 drops of buffer (approximately 120 μL) and start the timer. See illustration below.

3. Wait for the colored line(s) to appear. The test result should be read at 10 minutes. Do not interpret the result after 20 minutes.

 

PERFORMANCE CHARACTERISTICS of Streptococcal Infection Test

Sensitivity and Specificity

The recombinant antigen used for ACCU-TELL® HCV Cassette (Whole Blood/Serum/Plasma)is encoded by genes for both structural (nucleocapsid) and non-structural proteins. ACCU-TELL® HCV Cassette (Whole Blood/Serum/Plasma) has passed a seroconversion panel and compared with a leading commercial HCV test using clinical specimens.

The results show that the relative sensitivity of ACCU-TELL® HCV Cassette (Whole Blood/Serum/Plasma) is 100%, and the relative specificity is 99.8%.

 

Method

Leading commercial HCV test

Total Results

ACCU-TELL®   HCV Cassette

Results

Positive

Negative

Positive

410

3

413

Negative

0

1644

1644

Total Results

410

1647

2057

Relative sensitivity: 410/410=100.0% (95%CI*: 99.3%~100.0%);  

Relative specificity: 1644/1647=99.8% (95%CI*: 99.4%~100%);

Accuracy: (410+1644)/ (410+0+1644+3) =99.9% (95%CI*:99.6%~100.0%).     

*Confidence Intervals

Precision

Intra-Assay

Within-run precision has been determined by using 20 replicates of three specimens: a negative, a HCV low titer positive and a HCV high titer positive. The negative, HCV low titer positive and HCV high titer positive values were correctly identified 100% of the time.

Inter-Assay

Between-run precision has been determined by 20 independent assays on the same three specimens: a negative, a HCV low titer positive and a HCV high titer positive. Three different lots of ACCU-TELL® HCV Cassette (Whole Blood/Serum/Plasma) have been tested over a 3-month period using negative, HCV low titer positive and HCV high titer positive specimens.The specimens were correctly identified 100% of the time.

Cross-reactivity

ACCU-TELL® HCV Cassette (Whole Blood/Serum/Plasma) has been tested by HAMA, RF, HBsAg, HBsAb, HBeAg, HBeAb, HBcAb, Syphilis, HIV, H. Pylori, MONO, CMV, Rubella and TOXO positive specimens. The results showed no cross-reactivity.

Interfering Substances

The following potentially interfering substances were added to HCV negative and positive specimens.

Acetaminophen:  20 mg/dL                          

Caffeine: 20 mg/dL

Acetylsalicylic Acid:  20 mg/dL                     

Gentisic Acid: 20 mg/dL

Ascorbic Acid:  2g/dL                                     

Albumin: 2 g/dL

Creatin: 200 mg/dL                                        

Hemoglobin 1000mg/dL

Bilirubin: 1g/dL                                              

Oxalic Acid: 60mg/dL

None of the substances at the concentration tested interfered in the assay.

 

LIMITATIONS

1. ACCU-TELL® HCV Cassette (Whole Blood/Serum/Plasma) is for in vitro diagnostic use only. This test should be used for the detection of antibodies to HCV in whole blood, serum or plasma specimen.

2. ACCU-TELL® HCV Cassette (Whole Blood/Serum/Plasma) will only indicate the presence of antibodies to HCV in the specimen and should not be used as the sole criteria for the diagnosis of Hepatitis C viral infection.

3. As with all diagnostic tests, all results must be considered with other clinical information available to the physician.

4. If the test result is negative and clinical symptoms persist, additional follow-up testing using other clinical methods is recommended. A negative result at any time does not preclude the possibility of Hepatitis C Virus infection. We are Syphilis Rapid Test Strip Supplier.

 

Note: The above information is for reference use only. Please refer to the product insert provided with the products before use.

Payment Terms:TT, LC
Accu-Tell® HCV Rapid Test Cassette 1

Member Information

Accubiotech Co.,Ltd
Country/Region:Beijing - China
Business Nature:Manufacturer
Phone:18618286059
Contact:Andy Wang (manager)
Last Online:08 May, 2020