Acrel 300286.SZ BA10- AI/V AC current sensor isolate AC 0-50A current to DC 0-5

 Acrel 300286.SZ BA10- AI/V AC current sensor isolate AC 0-50A current to DC 0-5
Model:-
Brand:-
Origin:-
Category:Electronics & Electricity / Electronic Components / Potentiometer
Label: -
Price: -
Min. Order:-
Inquire Now

Product Description

General

BA series conduct the real-time measurement on the alternating current in the power grid according to the electromagnetic induction theory. They utilize the precise constant current technology and the linear temperature
compensation technology to isolate and convert the measured current into the DC signal. They adopt the 24V or 12V power supply.They feature the large overload capacity,high accuracy,isolation and safety and low power consumption.Application cover the industrial automation sector.
BA series residual current sensors are designed to monitor the electric leakage and detect the insulation of electrical circuit or electrical equipment in order to avoid accidents arising from reduction of insulation performance of electrical circuit orelectrical equipment.The product complies with GB/T13850-1998 and GB1208-2006.
.

Features

- Direct AC current measurement up to 600A
- Overload: 1.2 times of rated value
- Applied in Industrial automation

 

Technical Parameter

Model
Technical parameters

BA05

BA10

BA20

BA50

Accuracy

0.5class、0.2class


Input

Nominal value

AC0~(0.5~10)A

AC 0~( 8~50)A

AC 0~(40~200)A

AC 0~(60~600)A

Overload

Continual1.2 times, Instantaneous current 10 times/1s:

Absorbed power

≤1VA

Frequency response

25Hz~800Hz(average), 25~5kHz(true RMS),specially suitable for power frequency application

Output

Nominal value

DC4~20mA,or 0~20mA,0~5V,0~10V(And so on)

Load resistance

Current output ≤500Ω , Voltage output≥1KΩ

Response time

Average≤350ms, true RMS≤100ms

Power supply

Voltage

DC12V or 24V

Consumption

≤1W

Insulation resistance

>100MΩ

Isolation voltage

(Among input//output//power supply)2.0kV/1min,50Hz

Temperature modulus

-10℃~+55℃,≤100ppm/℃


Environment

Temperature

Work:-10℃~+55℃ Storage:-25℃~+70℃

Humidity

≤93%RH,(In the place without dew and corrosive gas)

Altitude

≤2000m


Installation

(TS35 rail mounting, or attached with screws in of the cabinet)

Product Specification

Model

Product function

Perforation(mm)

Enter the nominal value range

BA05-AI/I(V)

0-10A AC current signal acquisition, output 4-20mA or 0-5V DC signal

Φ5

AC0~(0.5~10)A

BA05-AI/I(V)-T

BA10-AI/I(V)

0-50A AC current signal acquisition, output 4-20mA or 0-5V DC signal

Φ10

AC0~(8~50)A

BA10-AI/I(V)-T

BA20-AI/I(V)

AC 0-200A current signal acquisition, output 4-20mA or 0-5V DC signal

Φ20

AC0~(40~200)A

BA20-AI/I(V)-T

BA50-AI/I(V)

AC 0-600A current signal acquisition, output 4-20mA or 0-5V DC signal

Φ50

AC0~(60~600)A

BA50-AI/I(V)-T

Quatation sheet

 Acrel 300286.SZ BA10- AI/V AC current sensor isolate AC 0-50A current to DC 0-5 1 Acrel 300286.SZ BA10- AI/V AC current sensor isolate AC 0-50A current to DC 0-5 2 Acrel 300286.SZ BA10- AI/V AC current sensor isolate AC 0-50A current to DC 0-5 3 Acrel 300286.SZ BA10- AI/V AC current sensor isolate AC 0-50A current to DC 0-5 4