380VAC Industrial water Cooled Chiller Cooling Glycol Chiller
Features:
1.Cooling capacity: 30HP(84,880Kcal/H)
2.Inlet/outlet freeze water temperature: 12℃/7℃( Example)
3.Refrigerant: R22, R134a, R407c, R410a
4.Power Supply: 3Φ-50Hz-380V
5.Compressor: Scroll Compressor(20%-30% higher in efficiency)
6.Freeze water flow:16.7m³/h
Details Images
Product Paramenters
Model |
SCY-20W |
SCY-25W |
SCY-30W |
SCY-40W |
SCY-50W |
|
Power supply |
3Φ-50Hz-380V(208-230V, 380-420V,440-480V,50Hz or 60Hz, 3phase) |
|||||
Cooling capacity |
kw |
66.8 |
78.8 |
98.7 |
133.6 |
157.6 |
TONS |
18.99 |
22.41 |
28.06 |
37.99 |
44.81 |
|
Kcal/h |
57450 |
67800 |
84880 |
114900 |
135700 |
|
Power consumption |
kw |
17.2 |
20.2 |
24.5 |
34 |
41.5 |
Running current |
A |
33.2 |
38.9 |
47.3 |
65.6 |
80 |
Freeze water flow |
m³/h |
11.1 |
13.2 |
16.7 |
22.2 |
26.4 |
Cooling water flow |
m³/h |
13.3 |
15.8 |
20 |
26.6 |
31.6 |
Compressor |
Type |
Scroll/piston |
||||
Input power(kw) |
15 |
18 |
22.5 |
30 |
37.5 |
|
Pump |
Power(kw) |
2.2 |
2.2 |
2.2 |
4 |
4 |
Refrigerant |
Type |
R22, R134a, R407c, R410a |
||||
Control method |
External balanced thermostatic expansion valve |
|||||
Filling volume(kg) |
11 |
13 |
16 |
22 |
26 |
|
Evaporator |
Type |
Shell and tube, Plate, Coil in Tank |
||||
Pipe diameter(in) |
2" |
2-1/2" |
3" |
|||
Condenser |
Type |
Shell and tube |
||||
Pipe diameter(in) |
2" |
2-1/2" |
3" |
|||
Safty protector |
Dual pressure switch, frost-proof protection, soluble pin/safety valve, overload protective device, coil over-heating protection
|
|||||
Dimension |
Length(mm) |
1700 |
1700 |
2100 |
2100 |
2100 |
Width(mm) |
800 |
900 |
900 |
1100 |
1100 |
|
Heiht(mm) |
1500 |
1500 |
1380 |
1430 |
1430 |
|
Weight(kg) |
630 |
680 |
850 |
900 |
1050 |
|
Remarks |
1.Testing results under above conditions: Inlet/outlet chilled water temperatuer 12℃/7℃, inlet/outlet cooling water temperature
|
|||||
2.The above parameters will be updated continuously. If you need a custom service, please send your technical requirements before
|
Recommend Products
Recommended by seller
Industrial Water Chiller with CE Approved Model SCY-80D
Air Cooled Manufacturing Water Cooling Air Chiller Industrial with CE Certificate
Indoor Box-type High Efficiency Water Chiller with CE Certificate, Inudtrial Chilling system
Industrial Chiller 380V Water Cooler Water Cooled Chiller Standing Chiller
Company Profile
ShenChuangYi(SCY) Refrigeration Equipment Co., Ltd is a professional manufacturer in making water-cooled chillers, air-cooled chillers, industrial chillers, low-temperature chillers, etc. Our factory covers 23500 square meters. Our main products include: Scroll water-cooled chillers, Air-cooled chillers(heat pump), Screw chillers, Low-temperature freezing chillers, Air-cooled freezing chillers, Heat-recycle chillers, Heat exchanger(condenser and evaporator), Water tower pump and other special refrigeration equipment. SCY has built a full quality control and management system under ISO9001 standard. From raw material inspection, production inspection, and overall inspection control, all processes follow a strict guideline. In order to keep the first-class quality, we inspect every product before sending out and make regular market research with our clients' help to improve the quality. With substantial support from all communities, we believe we can become better, stronger, and go further.
Shipping by sea
Available for the whole machine-industrial chillers
Shipping by express
Available for the spare parts of our chillers but fast speed
Shipping by air
Available for the spare parts of our chillers but fast speed
FAQ
Q1: How to calculate cooling capacity?
A: Please make sure the details first:
1. What’s the flow rate need?
2. Inlet(T1) and outlet(T2) temperature need?
Then we will calculate what’s the cooling capacity you need.
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-T2)/0.86
Q2: Cooling capacity unit conversion?
1 kcal/h = 1.163W, 1 W = 0.8598 kcal/h;
1 Btu/h = 0.2931W, 1 W = 3.412 Btu/h;
1 USRT = 3.517 kW, 1 kW = 0.28434 USRT;
Q3: How to choose the right chiller in all your models?
A: After making sure the cooling capacity, please inform us: 1. What's the power supply needed? Phase/Voltage/Frequency. 2. What's
the refrigerant needed? R22/R407C/R410A/R134A and etc. 3. All our chiller models can be customized to your demand.
Q4: What's the difference between water and air cooled chiller?
A: Water cooled chiller needs a SEPERATE cooling tower and has a higher heat exchange efficiency. Air-cooled chiller has no need
for an extra cooling tower, but with lower heat exchange efficiency.
If you still have some questions, please feel free to contact us for further assistance.
Payment Terms: | TT/LC/DP/DA |
---|---|
SCY chiller | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 18923440769 |
Contact: | Ms. Hou (Sales Manager) |
Last Online: | 20 Aug, 2020 |