Temperature Chamber Technical Parameters |
Temperature Range |
-10℃ ~ +80℃(Controllable) |
|
Temperature Rising Rate |
Ave.3℃/min(-10℃ to 80℃、Nonlinear No-load) |
|
Temperature Cooling Rate |
Ave.1℃/min(80℃ to 10℃、Nonlinear No-load) |
|
Inner Chamber Dimension |
W600 X H750 X D500 MM |
|
External Chamber Dimension |
W1170 X H1850 X D1020MM |
|
Inner Chamber Material |
Stainless steel with mirror-finish, bottom reinforcement |
|
External Chamber Material |
Cold-Rolled Steel with paint-baked coating |
|
Observation Window |
The single-opening door is accompanied by a 3-layer vacuum large glass observation window (W430mm x H 580mm); The door frame is equipped with electric heating (automatic adjustment) anti-frost, anti-condensation device; so that you can clearly observe the Test status of the test sample in the box through the observation window at any time. |
Internal Short Circuit Technical Parameters |
Max. Loading |
200KG |
|
Resolution |
1/10000 |
|
Force Accuracy |
≤0.5% |
|
Displacement resolution |
1/1000 |
|
Accuracy of displacement |
≤0.5% |
|
Speed Range |
0.01-5MM/S |
|
Effective Range |
0 ~ 200mm |
|
Max. Test Area |
300X300MM (Can be customized) |
|
Voltage Range |
0—60V |
|
Voltage Resolution |
5mV |
|
Voltage Acquisition Frequency |
100HZ |
Control System |
Servo motor + Servo control system |
Safety Protection |
Explosion-proof pressure relief device, smoke exhaust device, fire extinguishing system, electronic door lock system, safety stop switch |