Model: | Winner 2006 A/B |
---|---|
Brand: | Winner |
Origin: | Made In China |
Category: | Industrial Supplies / Other Industrial Supplies |
Label: | particle analyzer |
Price: |
US $11998
/ pc
|
Min. Order: | 1 pc |
Product Description
Winner2006A/B intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.01μm to 1000μm. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data. It enables you understand materials well, such as abrasives,adhesives, agrochemical,barite, Batteries, Bentonite, Boron Carbide, Brucite, Bubble,Calcite, Calcium Carbonate, Carbon Black, Catalysts, Cement, Ceramics, Chemicals, Clay, Coal, Coatings, Corundum, Cosmetics, Diamond Powder, Dolomite,Diatomite,Emulsion, Environmental, Explosives, Ferrite, Flour, Fluorescent, Fluorite, Food & Beverage, Food Additive,Graphite,Grinding, Inks, Kaolin, Medicine, Metal Powder, Mica, Milling, Minerals,Oxides,Paints, Paper, Petrochemical, Pharmaceuticals, Pigments, Plaster, Plastics, Polymers,Quartz,Refractory, Resins, Silica, slurry, Soil Sediments,Starch,Sulfur,Synthetics,Talc,Toners, Tourmaline,Wollastonite, Zeolite, Zirconium Silicate etc etc. Industry.
Main Features
(1)Unique Converging Light Fourier Transform Light Path, For better to test sub-micron particles, Adopt orthogonal double laserbeam patented technology, measure range expanded from 0.01/0.1μm-1000μm.
(2)Intelligent operation mode realize one key test, automatically supply-water,ultrasonic dispersion, circulate and drain off water, so it not only could decrease workload, but also get better repeatability after remove human-factors errors.
(3) Automatic optical light alignment system is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level,make light path be always in a good state.
(4)Liquid sample dispersion/preparation system: Full built-in setting mechanical stirring, ultrasonic dispersion, and circulation path in one, Big power-circulating pump and Optimization design of pipeline,effectively prevent large particle sediment.
(5)Software support: Original patent unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution.
(6) Output parameters:(D50, D03, D06, D10, D16, D25, D75, D84, D90, D97,D98,set any value, S/V, D[3,2],D[4,3] )
Specification
Model Name |
Winner2006A/Winner2006B |
||
Standard |
ISO13320-1:1999,GB/T19077.1-2008,Q/0100JWN001-2013 |
||
Principle |
MIE scattering theory |
||
Size range |
0.o1μm-1000μm/0.1μm-1000μm |
||
Detector Channels |
90pcs/87 pcs |
||
Accuracy error |
<0.5% (Deviation of D50 on national standard sample) |
||
Repeatability error |
<0.5% (Deviation of D50 on national standard sample) |
||
Laser |
He-Ne Laser λ= 632.8nm, p>2mW
|
||
Wet dispersion |
Ultrasonic |
Frequency:40KHz Power:60W, Time: ≥1S |
|
Agitator |
Revolutions Speed: 0-3000RPM (Adjustable) |
||
Circulation |
Rated Flow:17L/min Rated Power:15W |
||
Sample pool |
Volume: 450mL |
||
Operation mode |
Manual and Full automatic, 2 mode, freely choose |
||
Optical alignment system |
Full automatic optical path alignment system |
||
Software function |
Analysis mode |
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. |
|
Statistic Method |
Volume Distribution, Quantity Distribution |
||
Statistic Comparison |
Several Testing Results of samples
|
||
User-defined Analysis |
Figure out percentage according to the particle size
|
||
Test Report |
Word, Excel,Photo( Bmp), Text etc |
||
Multiple-language Support |
Multiple language Support |
||
Intelligent operation |
Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor |
||
Testing speed |
<2min/time |
||
Outer dimension |
L85cm*W39cm*H45cm |
||
Net weight |
40Kg |
Principle
Test Analysis View
Application
Winner2006A/B is widely used for cement, ceramic, medicine, dope, dye, padding, chemical products, catalyst, braize, dust, additive,pesticide, explosive, graphite, photosensitive material, fuel, metal and nonmetal powder, calcium carbonate, kaolin and other powder materials.
Quality Assurance
1. Strictly conforming to ISO9001-2000 quality management system.2. Strict control from purchasing materials, process inspection to final particle size distribution test.
3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale.
5.Laser particle size analyzer will be processed preventing -shake test before delivery.
After Sale Service
1.Operation demo video CD will be offered.
2. Offer free-training service.
3. The quality assurance date is 1 year since finishing payment, Technology support will be provided for life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).
5. We offer the components with favorable price and perdurable maintenance.
Jinan Winner Particle Instrument Stock Co., Ltd. | |
---|---|
Country/Region: | Shan Dong - China |
Business Nature: | Manufacturer |
Phone: | 17362290807 |
Contact: | Ella Ren (Foreign trade operat) |