Winner 2308 wet and dry particle size analyzer

Winner 2308 wet and dry particle size analyzer
Model:Winner 2308 A/B
Brand:Winner
Origin:Made In China
Category:Industrial Supplies / Industrial Supplies Stocks
Label:wet and dry
Price: US $33598 / pc
Min. Order:1 pc

Product Description

 

Product Description

Winner2308A/B intelligent full automatic wet&dry laser particle size analyzer adopt laser diffraction theory(Mie and Fraunhofer diffraction), measure size is from 0.1μm/0.01μm to 1200μm/2000μm, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, It’s the prior choice for industrial production quality control departments and research institutions.

Main Features

(1)Wet and dry sample dispersion system Integrated Design
Winner2308 intelligent laser particle size analyzer which is 1st set laser particle size analyzer integrated wet and dry dispersion test in one in China, it successfully resolved the problem of dry and wet technology integration, realize one key to switch, apply to test all the particle size distribution from 0.01μm-2000μm particles.

(2) Intelligent full automatic operation system and manual operation mode, freely choose.
With intelligent automatic mode of operation, to achieve a key test, as long as according to the prompt addition of sample, click the "test", all process will be complete automatically, not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.

Wet method: A key to complete water-supply, ultrasonic dispersion, circulation, testing, cleaning, data record, data analysis,save and print are automatically completed, only take 2 mins.
Dry method: A key to complete the dust collecting, compressed air supply, feeding, testing(The patented technology of turbulence dispersion and the sample window of the negative pressure device make the sample be fully dispersed), data processing and other operation, take 1 min.

(3) Stable and unique optical path system patented technology
Converging light Fourier transform path patent technology, enables scattering light be not restricted to the lens aperture limit,using Double Spectral plane optical path design, the Photodetector channels are 127 pcs, the maximum detection angle is 145 degrees and the minimum detection angle is 0.0155 degrees, Using dual-laser orthogonal light patent technology, The measurement range is effectively extended to 2000 microns. Canon Fourier lens imported from Japan is used to ensure the stability and accuracy
of particle measurement.

(4) Automatic Optical path alignment System,
The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.1um, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.


(5) Full built-in Sample Wet and dry dispersion system,One key switch.
Auto wet dispersion system,SOP realize one key operation.
set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, And it guarantees the representativeness of test result.

For dry dispersion system, Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion,ensure good test,apply to test powders range from 0.1 micron to 1200 micron.


(6)Instrument Software
Original Unconstrained free fitting patent technology collect scattering data during the measurement process, make particle analysis not be restricted by any functions, truly reflect particles size distribution, The instrument provide high precision data with 10Khz data acquisition time.

Specification

Model Name

Winner2308A|Winner2308B

Standard

ISO13320-1:2009,GB/T19007-2016,Q/0100JWN001-2013
Compliance with 21 CFR Part 11

Principle

Laser diffraction principle

Analysis

Mie and Fraunhofer scattering

Detector Arrangement

Log-spaced array, test angle from 0.015 degree to 145 degree

Measuring Range

Wet:0.01μm-2000 μm Dry: 0.1μm-2000μm |Wet:0.01μm-1200 μm Dry: 0.1μm-1200μm

Silicon Photodetectors

Wet:127 pcs Dry:100 pcs

Accuracy error

Wet≤0.5% Dry≤1% (CRM D50)

Repeatability error

Wet≤0.5% Dry≤1% (CRM D50)

Light source

High performance semiconductor red laser (λ=639nm )
P>3.0MW
Auxiliary green solid semiconductor laser (λ= 405 nm)
P>2.0MW (available)

Optical path

Converging light Fourier transform optical path

Effective focal length

500mm

Laser Safety

Class 1

Wet dispersion

Ultrasonic

Frequency:40KHz Power:60W, Time: ≥1S

Stir

Revolutions Speed: 0-3000RPM (Adjustable)

Circulate

Rated Flow:30L/min Rated Power:70W

Water level sensor (UK

Prevent water overflow and effectively protect the instrument

Sample tank

Volume:1000mL

Micro-
Sample cuvette

Volume: 10mL ( Available)

Dry dispersion

Dry-turbulence dispersion patent technology, normal shock wave shear technique

Feeding Speed

Adjustable (Variable speed knob)

Operation Mode

Full automatic / manual control, freely choose

Dispersion medium

Compressed Air, pressure: 0 to 6 bar

Optical bench alignment system

Full automatic, precision is up to 0.2um

Full Test Speed per time

Wet: <2 Min Dry : <1min
Inverval time per test result :500ms

Outer dimension

L104cm×W44cm×H54cm

Net Weight

58Kg

 

Principle

Test Operation Interface:

Our Customers

 

Quality Assurance

1. Strictly conforming to ISO9001-2000 quality management system.2. Strict control from purchasing materials, process inspection to final particle size distribution test.

3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale.
5.Laser particle size analyzer will be processed preventing -shake test before delivery.

 

After Sale Service
1.Operation demo video CD will be offered.

2. Offer free-training service.

3. The quality assurance date is 1 year since finishing payment, Technology support will be provided for life. And after that, we will collect the cost if provide repair accessories.

4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).

5. We offer the components with favorable price and perdurable maintenance.

Winner 2308 wet and dry particle size analyzer 1Winner 2308 wet and dry particle size analyzer 2Winner 2308 wet and dry particle size analyzer 3Winner 2308 wet and dry particle size analyzer 4

Member Information

Jinan Winner Particle Instrument Stock Co., Ltd.
Country/Region:Shan Dong - China
Business Nature:Manufacturer
Phone:17362290807
Contact:Ella Ren (Foreign trade operat)
Last Online:13 Oct, 2023