Model BNF6533120 BNF6550120 BNF657580 BNF6512052 BNF6513547 BNF6515042 BNF6524027 BNF6527024 BNF65480135
Output DC voltage 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
Rated current 12A 12A 8A 5.2A 4.7A 4.2A 2.7A 2.4A 1.35A
Current range 0~12A 0~12A 0~8A 0~5.2A 0~4.7A 0~4.2A 0~2.7A 0~2.4A 0~1.35A
Rated power 39.6W 60W 60W 62.3W 63.5W 63W 64.8W 64.8W 64.8W
Ripple & Noise 80mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p 100mVp-p
Voltage adjust range 3.14~3.63V 4.75~5.5V 7.13~8.25V 11.4~13.2V 12.8~14.9V 14.25~16.5V 22.8~26.4V 25.65~29.7V 45.6~52.8V
Voltage tolerance ±3% ±3% ±3% ±2% ±2% ±2% ±2% ±2% ±2%
Line regulation ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1%
Load regulation ±3% ±3% ±3% ±2% ±2% ±2% ±2% ±2% ±2%
Set up time, Rise time 800ms,20ms at full load
Hold-up time 60ms at full load
Input Voltage range 90~264Vac, 135~370Vdc
Frequency range 47~63Hz
Efficiency  ±69% ±76% ±79% ±79% ±79% ±79% ±80% ±80% ±80%
AC current 1.2A/115Vac; 0.72A/230Vac
Inrush current (max.) Cold start 20A/115Vac, 40A/230Vac
Leakage current(max.) <0.75mA/240Vac
Protection Over load 73~105W (3.3V:51 ~75W) (5V:70~105W) rated output power
Protection type:hiccup mode,recovers automatically after fault condition is removed
Over voltage 3.8~4.46V 5.75~6.75V 8.63~10.1V 13.8~16.2V 15.5~18.2V 17.25~20.25V 27.6~32.4V 31~36.45V 55.2~64.8V
Protection type:hiccup mode,recovers automatically after fault condition is removed
Environment Working Temp. -10~+40℃ 
Working Humidity 20%~90% RH non-condensing 
Storage Temp. Humidity -20℃~85℃, 10%~95% RH
Temp. Coefficient ±0.04%/℃ (0~50℃)
Vibration 10~500Hz, 2G 10min/ cycle,period for 60 min,each along X,Y,Z axes
Safety & EMC Safety Standard  UL60950-1, EN60950-1;EN60065
Withstand voltage  I/P-O/P:3KVac
Isolation resistance I/P-O/P: 100M ohms/500Vdc
EMI condition & radiation  Compliance to EN55022 class B, FCC part15 class B
Harmonic current Compliance to EN6100-3-2,3
EMS immunity Compliance to EN6100-4-2
Others MTBF 100Khrs min, MIL-HDBK-217F(25℃)
Dimension 120mm*72mm*35mm
Packing  ---------
Note 1.Al l parameters are specified at 230Vac input, rated load,25℃ 70% RH ambient;
3.Ripple & Niose are measured at 20Mhz bandwidth by using a 30cm twisted-pair wire terminated with a 0.1uf & 47uf parallel capacitor 
4.Tolerance: includes set up tolerance, line regulation, load regulation,
5.Line regulation is measured from low line to high line at rated load,
6.Load regulation is measured from 0%~100% at rated load
8.The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that is 
   still meets EMC derectives.
Model BNF6533120 BNF6550120 BNF657580 BNF6512052 BNF6513547 BNF6515042 BNF6524027 BNF6527024 BNF65480135
Output DC voltage 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
Rated current 12A 12A 8A 5.2A 4.7A 4.2A 2.7A 2.4A 1.35A
Current range 0~12A 0~12A 0~8A 0~5.2A 0~4.7A 0~4.2A 0~2.7A 0~2.4A 0~1.35A
Rated power 39.6W 60W 60W 62.3W 63.5W 63W 64.8W 64.8W 64.8W
Ripple & Noise 80mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p 100mVp-p
Voltage adjust range 3.14~3.63V 4.75~5.5V 7.13~8.25V 11.4~13.2V 12.8~14.9V 14.25~16.5V 22.8~26.4V 25.65~29.7V 45.6~52.8V
Voltage tolerance ±3% ±3% ±3% ±2% ±2% ±2% ±2% ±2% ±2%
Line regulation ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1%
Load regulation ±3% ±3% ±3% ±2% ±2% ±2% ±2% ±2% ±2%
Set up time, Rise time 800ms,20ms at full load
Hold-up time 60ms at full load
Input Voltage range 90~264Vac, 135~370Vdc
Frequency range 47~63Hz
Efficiency  ±69% ±76% ±79% ±79% ±79% ±79% ±80% ±80% ±80%
AC current 1.2A/115Vac; 0.72A/230Vac
Inrush current (max.) Cold start 20A/115Vac, 40A/230Vac
Leakage current(max.) <0.75mA/240Vac
Protection Over load 73~105W (3.3V:51 ~75W) (5V:70~105W) rated output power
Protection type:hiccup mode,recovers automatically after fault condition is removed
Over voltage 3.8~4.46V 5.75~6.75V 8.63~10.1V 13.8~16.2V 15.5~18.2V 17.25~20.25V 27.6~32.4V 31~36.45V 55.2~64.8V
Protection type:hiccup mode,recovers automatically after fault condition is removed
Environment Working Temp. -10~+40℃ 
Working Humidity 20%~90% RH non-condensing 
Storage Temp. Humidity -20℃~85℃, 10%~95% RH
Temp. Coefficient ±0.04%/℃ (0~50℃)
Vibration 10~500Hz, 2G 10min/ cycle,period for 60 min,each along X,Y,Z axes
Safety & EMC Safety Standard  UL60950-1, EN60950-1;EN60065
Withstand voltage  I/P-O/P:3KVac
Isolation resistance I/P-O/P: 100M ohms/500Vdc
EMI condition & radiation  Compliance to EN55022 class B, FCC part15 class B
Harmonic current Compliance to EN6100-3-2,3
EMS immunity Compliance to EN6100-4-2
Others MTBF 100Khrs min, MIL-HDBK-217F(25℃)
Dimension 120mm*72mm*35mm
Packing  ---------
Note 1.Al l parameters are specified at 230Vac input, rated load,25℃ 70% RH ambient;
3.Ripple & Niose are measured at 20Mhz bandwidth by using a 30cm twisted-pair wire terminated with a 0.1uf & 47uf parallel capacitor 
4.Tolerance: includes set up tolerance, line regulation, load regulation,
5.Line regulation is measured from low line to high line at rated load,
6.Load regulation is measured from 0%~100% at rated load
8.The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that is 
   still meets EMC derectives.
 
65W Open Frame Power Supply 1

Member Information

Shenzhen Billionet Technology Company Ltd
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:13652433100
Contact:Tina ( Marketing Manager)
Last Online:25 Jun, 2012