UL HLR1000-024AT1H2Q(SPNO/40A/24VAC) Water heater relay

UL HLR1000-024AT1H2Q(SPNO/40A/24VAC) Water heater  relay
Model:SPNO/40A/24VAC
Brand:HONGLI
Origin:Made In China
Category:Electronics & Electricity / Electronic Components / Relay & Contactor
Label:Power Relay , Relay , Motor Relay
Price: US $6.4 / pc
Min. Order:1000 pc

Product Description

1.Applicable and Description

1. Applicable Scope
HLR1000-024AT1H2Q (SPNO/40A/24VAC)General Purpose Relay
,Mainly Is Suitable For 50Hz Or 60Hz,  Fixed Working Voltage Is 240V Or 277V, DC voltage to 220V control ciruit, Is Suitable in the fixed operating current 40A (AC-8a );30A(AC-8b) Single-phase air conditioning's Compressor or motor control,May also use in electric appliances and equipment's and so on electric heating,power tool and each kind of electric motor,  this product has the volume to be small , the weight is light , the coil power  loss is low, the contact load is big , and so on redundant reliability.

2.Type and Meaning

HL R 1000 - 024 A T 1H 2Q
HONGLI Relay Series Bulk Pack  24 V AC Quick Contact Contact Arrangment  Double1/4"QC
2. Product Explanation And Main Technical Parameter

Type

HLR1000-024AT1H2Q

Rating of current

Ie : 40A

Rating of contacts voltage

Ue : 240/277(V)

Rating of insulation voltage

Ui : 600(V)

Rating of coil voltage

Us : 24(V)

Mechanical life

1,000,000 times

Electricity life

100,000 times

Product Explanation

1 .The Regular Service Conditon And Installs The Condition
a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets
Down The Limiting Value Is -25
b. The Installation Site Elevation Does Not Surpass 2000m
c. The Air Pollution Rank Is 2 Levels
d. Installs The Category Is Ii ;
e. Installment Facing The Gradient Does Not Surpass ±5°
f. Not Remarkable Undulation, Impact And Vibration Place.
2 .Main Technical Parameter 
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably
Working, Its Drop Out Voltage In 20% ~ 70%Us
b. Contactor Use Category: Ac-1Ac8a
c. Contactor In With 0.4m Place, Its Noise Below 40db
3 . Installing Specification And Install Size
a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°

b. Before The Use Should Inspect The Power Terminal And The Contactor
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating
The Breakdown, Behind Check Off May Electrify Tries .

3.Conforms To The Standard

 

1 、Conforms To UL508, IEC60947, GB14048 Standard
2 、Approved By UL,ROHS,and ISO9001 System Certification(SGS)

   UL Files Number:   E251539

4.Ordering Request

If You Request As Follows: Nominal Current:40A(ACI), Working Voltage: 277V, Pole Number:One pole , Coil Control Voltage:24VAC, Wiring way:Double 1/4 QC. Load Current: Single-Phase Motor Controls Or linear Load, Packing: 120/Each Box (Factory Packing),  Then You May Be Elect The Type : HLR1000- 024AT1H2Q

Ie Pole Rating of Coil Control Voltage Motor Power
24VAC 120VAC 208/240VAC 277VAC 480VAC 240VAC
40A 1P HLR-024AT1H2Q HLR-120AT1H2Q HLR-240AT1H2Q HLR-277AT1H2Q HLR-480AT1H2Q 2.5Kw
    HONGLI ELECTRIC HLR1000 Series PRODUCT CATALOG
DownLoad PDF DataSheet