1.Applicable and Description
1. Applicable Scope
HLR1000-024DT1H2Q (SPNO/40A/24VDC) General Purpose Relay,Mainly Is Suitable For 50Hz Or 60Hz, Fixed Working Voltage Is 240V Or 277V, DC voltage to 220V control ciruit, Is Suitable in the fixed operating current 40A (AC-8a );30A(AC-8b) Single-phase air conditioning's Compressor or motor control,May also use in electric appliances and equipment's and so on electric heating,power tool and each kind of electric motor, this product has the volume to be small , the weight is light , the coil power loss is low, the contact load is big , and so on redundant reliability.
|
2.Type and Meaning
|
HL |
R |
1000 |
- |
024 |
D |
T |
1H |
2Q |
HONGLI |
Relay |
Series |
Bulk Pack |
24 V |
DC |
Quick Contact |
Contact Arrangment |
Double1/4"QC |
|
2. Product Explanation And Main Technical Parameter |
Type |
HLR1000-024DT1H2Q |
Rating of current |
Ie : 40A |
Rating of contacts voltage |
Ue : 240/277(V) |
Rating of insulation voltage |
Ui : 600(V) |
Rating of coil voltage |
Us : 24(V) |
Mechanical life |
1,000,000 times |
Electricity life |
100,000 times |
Product Explanation |
1 .The Regular Service Conditon And Installs The Condition
a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets
Down The Limiting Value Is -25
b. The Installation Site Elevation Does Not Surpass 2000m
c. The Air Pollution Rank Is 2 Levels
d. Installs The Category Is Ii ;
e. Installment Facing The Gradient Does Not Surpass ±5°
f. Not Remarkable Undulation, Impact And Vibration Place.
2 .Main Technical Parameter
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably
Working, Its Drop Out Voltage In 20% ~ 70%Us
b. Contactor Use Category: Ac-1Ac8a
c. Contactor In With 0.4m Place, Its Noise Below 40db
3 . Installing Specification And Install Size
a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°
b. Before The Use Should Inspect The Power Terminal And The Contactor
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating
The Breakdown, Behind Check Off May Electrify Tries .
|
|
3.Conforms To The Standard |
|
1 、Conforms To UL508, IEC60947, GB14048 Standard |
2 、Approved By UL,ROHS,and ISO9001 System Certification(SGS) |
UL Files Number: E251539
|
|
4.Ordering Request |
In order to guarantee you use need, when you order please in detail explain:
If You Request As Follows: Nominal Current:40A(ACI), Working Voltage: 277V, Pole Number:One pole , Coil Control Voltage:24VDC Wiring way:Double1/4"QC.Load Current: Single-Phase Motor Controls Or linear Load, Packing: 120/Each Box (Factory Packing), Then You May Be Elect The Type : HLR1000- 024DT1H2Q
Ie |
Pole |
Rating of Coil Control Voltage |
Motor Power |
24VDC |
120VDC |
208/240VDC |
277VDC |
480VDC |
240VAC |
40A |
1P |
HLR-024DT1H2Q |
HLR-120DT1H2Q |
HLR-240DT1H2Q |
HLR-277DT1H2Q |
HLR-480DT1H2Q |
2.5Kw |
|