630mA medical x-ray equipment:
Model:YSX0603
1) Microcomputer control x-ray radiography assembles: optional 600mA or 50KW.
2) Total 432 storage combination controlled by element such as kV mA S is applied radiography for the following filed three body position, fat middle and thin body type, automatic detect and display cod of mistake in system, send warning signal, detect accuracy and maintain.
3) X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protectorate provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.
4) Bulb type over remote-controlled diagnostic table and image intensifier television system are installed. They realize not only bright operation, but also supply convenience for science resonator suffer are reduced. Specifications of automatic spot-film are abundant. There are also automatic collimators for users convenience.
5) Applied in all kinds of hospital for radiography such as general body、beam filtration、and chest
Department |
Technology parameters |
|||
High voltage generator control table and high voltage transform assemble |
Fluoroscopy |
Tube currency |
0.3-5mA continuous currency |
|
Tube voltage |
50-110KV continuous voltage |
|||
Radiography |
Tube currency |
32-630mA shift |
||
Tube voltage |
45-125KV continuous voltage |
|||
Exposure time |
0.01-6.3s 23 shift |
|||
Power |
Voltage |
380V±10% |
||
Frequency |
50Hz±1Hz |
|||
Capacity |
≥50KVA |
|||
Inner resistance |
≤0.3Ω |
|||
X-ray assembly |
Focus |
1×1.2×2 double focal |
||
Rated rotate speed of anode |
2800r/min |
|||
Changed beam limited device |
Diagnosis table YS09D |
Automatic, adjusted field of view |
||
CS15Electro-motion diagnostic table |
The table body rotation |
"-15°~0°~+90°" |
||
Focus to film distance |
1100~1500mm,adjustable manual |
|||
360°foot board |
||||
The table to height |
870mm |
|||
Stationary grid |
Grid density |
40L/cm |
||
Grid ration |
10:01 |
|||
Focusing distance |
120cm |
|||
Spot film device |
Scope of moving |
Longitudinal moving: 900mm; |
||
Transverse moving: ±120mm |
||||
Specification of scope film |
Full :8"×10", 10"×12", 11"×14", 14"×14" |
|||
Two: 8"×10", 10"×12" |
||||
Three:11"×14", 14"×14" |
||||
Four: 11"×14", 14"×14" |
||||
Medical television system |
configuration |
9″x-ray image intensifier made by Toshiba, CCD camera,14″ high resolution monitor |
||
14″monitor |
resolution |
Horizontal center≥1000 TV line |
||
Gray scale |
≥10 grades |
|||
Video width |
>12MHZ |
|||
Mode of scan |
625 lines, 5 field, Interlaced scanning |
|||
Geometry distortion |
<2% |
|||
SNR |
≥40db |
|||
Power supply |
220V 50Hz AC |
|||
9″x-ray image intensifier made by Toshiba |
resolution |
≥46LP/mm |
||
Conversion modulus |
34cd/m2/μGY/s |
|||
Contrast |
10% area: 30:1, Φ10mm area: 18:1 |
|||
CCDJapan Camera |
Specification |
1/2″, anti-halation, CCIR752×586. |