Main Technical Data:
1.externality size: 450mmx310mmx150mm
2.Max. self consumption: less than 3W
3.Accuracy of temperature measuring: +/-2 degrees centigrade
4.Range of temperature measuring: 0-150 degrees centigrade
5.Power of controlled pumps (temperature difference circulation pump, water-using end circulation pump): more than 600W
6.electronic booster power: less than 3000W
7.system working pressure: 0.6MPA
8.input signal: 3 temperature sensors (for top of tank, for heat collector, for bottom of tank)
9.output signal: 3 (electronic booster, temperature difference circulation pump and water-using end circulation pump)
Main Functions:
1.display clock and week
2.display temperature
3.temperature difference circulation pump provide three working scopes for choose
4.temperature difference circulation
5.three periods timing circulation for pipeline
6.three periods timing heating
7.memory function
8.display the fault of water tank temperature
9.display the flux
10.display the system pressure
11.frost protection for collector
12.high temperature protection for water tank
13.high temperature protection for solar collector