Features:
- Handheld, battery-operated design
- Weighs less than 5 lbs. (including battery)
- Built-in worldwide signal standards and frequency channels
- Superior Immunity to RF interference
- Locate long range problems with 517 data points
- Pop-up cable menus containing over 95 cable types
- Multilingual User Interface; English, French, Chinese, Japanese, Spanish, German
- Intuitive and easy to use with On-Screen Test Set-Ups
- Saves up to 25 Measurement Test Set-Ups - S331D (Cable and Antenna Analyzer: 10, Power Meter: 5, T1 Analyzer: 5, and E1 Analyzer: 5).
- Saves up to 20 Measurement Test Set-Ups - S331D(Cable and Antenna Analyzer: 10, Spectrum Analyzer: 5, and Power Meter: 5)
- Saves up to 200 Measurement Traces
- Alphanumeric Labeling of Saved Measurements
- Automatic Time and Date Stamp of Saved Data
- Rechargeable, Field Replaceable Battery
- Distance Measurement in Feet and Meters
- Information Screens Provide Cable Attenuation and Velocity of Propagation values
- 6 Markers, Limit Lines, and Segmented Limit Lines
- RS232 Interface |
Options:
-2 MHz Frequency Extension(Option 2)
-6 GHz Frequency Extension(Option 16)
-Power Monitor(Option 5)
-High Accuracy Power Meter,Sensor PSN50 not included(Option 19)
-GPS Receiver,includes GPS antenna 2000-1410(Option 31)
-T1/E1 Analyzer(Option 50)
Applications:
- Cable and antenna testing for VHF,broadcasting,paping,cellular,PCS/GSM,3G,ISM,WLAN and WLL applications.
- Return Loss measurement
- Distance-To-Fault measurement
- Cable loss measurement
- Channel power |
Cable and Antenna Analyzer |
Frequency Range: |
25 MHz to 4.0 GHz |
Frequency Accuracy: |
~ ±75 ppm @ +25 C |
Frequency Resolution: |
100 kHz |
Output Power: |
<0 dBm (–10 dBm nominal) |
Immunity to Interfering Signals: |
on-channel |
+17 dBm |
on-frequency |
–5 dBm |
Measurement speed: |
~3.5 msec / data point (CW ON) |
Number of data points: |
130, 259, 517 |
Return Loss: |
Range: 0.00 to 60.00 dB
Resolution: 0.01 dB |
VSWR: |
Range: 1.00 to 65.00
Resolution: 0.01 |
Cable Loss: |
Range: 0.00 to 30.00 dB
Resolution: 0.01 dB |
Measurement Accuracy: |
>42 dB corrected directivity after calibration |
Distance-To-Fault |
Vertical Range: |
Return Loss: 0.00 to 60.00 dB VSWR: 1.00 to 65.00 |
Horizontal Range: |
Range: 0 to (# of data pts –1) x Resolution to a maximum of 1197 m (3929 ft), # of data pts = 130, 259, 517 |
Horizontal Resolution (Rectangular windowing): |
Resolution (meter) = (1.5 x 10^8) x (Vp)/DF Where Vp is the cable's relative propagation velocity and where DF is the stop frequency
minus the start frequency (in Hz) |
|
General |
Language Suppot |
Chinese,English,French,Geman,Japanese,Spanish, |
Internal Trace Memory: |
200 traces |
Setup Configuration: |
S331D - 25 |
Display: |
VGA monochrome or VGA color LCD (Option 3) with adjustable backlight |
Inputs and Outputs Ports: |
RF Out:Maximum Input without Damage: |
Type N, female, 50~+23 dBm, ± 50 VDC |
RF In:Maximum Input without Damage: |
Type N, female, 50~+43 dBm (Peak), ± 50 VDC |
Ext. Trig In: |
BNC, female (5 V TTL) (S332D Models only) |
Ext. Freq Ref In (2 to 20 MHz): |
Shared BNC, female, 50~ , (–15 dBm to +10 dBm) (S332D Models only) |
T1/E1 (Receive & Transmit): |
Bantam Jack (S331D Models with Option 50 only) |
Serial Interface: |
RS-232 9 pin D-sub, three wire serial |
Electromagnetic Compatibility: |
Meets European Community requirements for CE marking |
Safety: |
Conforms to EN 61010-1 for Class 1 portable equipment |
Temperature: |
Operating: |
–10°C to 55°C, humidity 85% or less |
Non-operating: |
–51°C to +71°C (recommended battery to store separately between 0°C to +40°C for any prolonged non-operating storage period) |
Environmental: |
MIL-PRF-28800F Class 2 |
Power Supply: |
External DC Input: |
+12.5 to +15 volt dc, 1350 mA max |
Internal: |
NiMH battery: 10.8 volts, 1800 mAH |
Dimensions: |
Size (w x h x d): |
25.4 cm x 17.8 cm x 6.1 cm (10.0 in x 7.0 in x 2.4 in) |
Weight: |
<2.28 kg (<5 lbs) includes battery |
|
|
|
|