S Beam Load Cell (T-BXB)

S Beam Load Cell (T-BXB)
Model:T-BXB
Brand:GOLDBELL
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Balance & Scale Apparatus
Label:load cell , s beam load cell , weighing transmitter
Price: -
Min. Order:12 pc
Inquire Now

Product Description

Major uses

Suitable for electro-mechanic scale, crane scale, hopper scale, special scale and so on.

 

Features

T-BXB (made of alloy steel) type load cell, measuring by shearing stress method, can take both tension and compression. It has good output symmetry, compact structure and is easily installed. Capacity from 200kg to 5t, specifications are complete. The load cell has protection grade specified as IP67. T-BXB-2 type load cell has passed 1.5 million times of anti-fatigue test.

 

Product Details:

Place of Origin

Shandong China

Brand Name

Goldbell

Model Number

T-BXB

Payment & Shipping Terms:

Minimum Order Quantity:

12 Piece/Pieces

Payment Terms:

L/C,T/T

 

Detailed Product Description

 

T-BXB S type load cell

OIML approval

Alloy steel structure

Capacity

kg

200, 300, 500

t

1, 2, 5

Sensitivity

mV/V

2.0±0.01 (3±0.01)

Accuracy class

 

C3

C2

0.05

Maximum number of load cell interval

 

3000

2000

 

Minimum load cell verification interval

 

Emax /10000

Emax /7000

 

Combined error

%F. S.

0.02

0.023

0.05

Repeatability

%F. S.

0.01

0.015

0.03

Creep

%F. S. / 30min

±0.0245

±0.0245

±0.05

Minimum dead load output return

%F. S.

±0.017

±0.025

±0.05

Temp. effect on min. dead load output

%F. S. / 5

±0.007

±0.010

±0.025

Temp. effect on sensitivity

%F. S. / 5

±0.007

±0.009

±0.025

Minimum dead load

%Emax

1

Maximum safe overload

%Emax

150

Ultimate overload

%Emax

200

Supply voltage

V

10 ~ 15 ( DC/ AC)

Zero balance

%F. S.

±1

Input resistance

Ω

410 ~ 460 (2t: 390 ~ 450, 5t: 400 ~ 450)

Output resistance

Ω

349 ~ 355

Insulation resistance

≥ 5000

Compensated temperature range

 

-10 ~ +40

Operating temperature range

 

-30 ~ +70

Connect cable

mm

4.7 * 5000 

Method of connecting wire

  

Input(+): Red        Input(-): White

Output(+): Green     Output(-): Blue

Shield: Yellow

 

S Beam Load Cell (T-BXB) 1S Beam Load Cell (T-BXB) 2S Beam Load Cell (T-BXB) 3S Beam Load Cell (T-BXB) 4

Member Information

jinan jinzhong electronic scale company Ltd.
Country/Region:Shan Dong - China
Business Nature:Manufacturer
Phone:4006586579
Contact:Fu Shihan (Manager)
Last Online:18 Jun, 2012