The Abstract of Tecka Product Characters
Ⅱ,Tecka Water Cooled Screw Type Chillers.
1、Disturbed built-in distributor together with E2C type tubes and C type tubes conduces the high efficiency of the unit.
2、No-oil film high efficiency heat exchanger technology.
3、Zero defect protection.
4、Industrial class PLC intellectual control;
5、Multi buffer, low vibration and low noise.
6、Industrial aesthetic design.
7、Multi working condition analog data testing systems (testing labs)
Ⅱ Tecka screw type water/ground heat pump chillers.
1、Inherit the Tecka traditional advantage in application of screw type compressors.
2、Apply the international famous semi-hermetic double screw type compressors special for heat pump unit.
3、Creatively apply the disturbed built-in distributor technology in evaporator. 4、Computer selection according to the different hydraulic and soil conditions of different places.
5、High temperature leaving water unit by using the waste heat (85C utmost).
6、Multi working conditions dynamic analog data testing system (testing lab).
Ⅲ Tecka air cooled screw type water chillers (heat pump)
1、Rich professional experience in designing and manufacturing the air cooled (heat pump) chiller(since 1991)
2、Regionalization design idea make sure the highest efficiency of the unit in different climate.
3、Apply unique frosting delay technology and adaptive defrosting technology.
5、Apply patent “ inductive” return oil technology to make sure the safe oil return in any working condition.
6、Apply modular design to increase the precision of capacity adjustment and decrease the damage of the start of the power.
7、“0 defect” protection idea to make sure the safe operation of the unit( the protection of the compressor in PPT).
8、CFD dynamic simulation technology make the flow field and the temperature field even and reasonable. (CFD is a simulation software, which simulate the air flow field of the air side dynamically to designed the more scientific structure of the air side heat exchanger)
9、Apply high efficiency hydrophilic clothing aluminum fins at the air side heat exchanger.
10、Flow distributing technology.
Ⅳ, Tecka Roof-top (heat pump) unit.
1、Inherit the Tecka traditional advantage in application of screw type compressors.
2、Apply high-efficiency scroll type or semi-hermetic screw type compressors special for heat pump unit.
4、Unit has multi-types return air and functions available.
5、Air side big enthalpy design reduce the volume of supply/ return air ducts.
6、The software for design the cooling coil under multi working conditions makes the system more reasonable.
Ⅴ, Tecka modular type air handling unit.
1、Design the AHUs strictly according to the China national standard GB/T14294-93 and European standard EN1886-1998;
2、Apply Tecka patent buckle-lock technology.
3、Apply aluminum alloy profile bar and double deck high density Freon-free polyurethane foaming structure.
4、Apply computer software to select the panel thickness, profile bar type fan/motor model.
5、Apply natural drainage anti-freezing structure to design the cooling coil.
6、Apply asepsis declining dry type drain pan.
7、Apply multi working conditions software to design the cooling coil.
Ⅵ, Tecka air handling unit.
1、Design the AHUs strictly according to the China national standard GB/T14294-93 and European standard EN1886-1998;
2、Apply natural drainage anti-freezing structure to design the cooling coil.
3、Choose humidifier, frequency converter motor, pre-filter/mid-filter, heat recovery equipment to satisfy different clients.
4、The ceiling suspended type and horizontal/ vertical type unit with large ESP range are available.
5、Apply multi working conditions software to design the cooling coil.
Ⅶ, Tecka air ductless fluidic air handling unit
1、Combined with the traditional technology of Air handling unit, the air ductless fluidic air handling unit is suitable for used in large space with the biggest supply air distance as 60M.
2、Select the ball type nozzle by computer with big air flow, long injection distance and low noise.
3、The supply air angle can be flexibly adjusted in ±30℃ range.
4、Apply natural drainage anti-freezing structure to design the cooling coil.
5、The first investment and the maintenance cost is low.
ⅧTecka fan coil unit
1、Design with hydrophilic clothing heat exchanger result in easy drainage, anti-erosion, anti-dust and high efficiency.
2、The unit is designed with optimized matching, with good looking and low noise.
3、New type lengthened drain pan, without cold bridge, seeper or condensing water.
4、Double corrugated fins make sure the good air flow inside.