Three phase 10-slot multi-functional watthour meter calibration system

Three phase 10-slot multi-functional watthour meter calibration system
Model:SJJ-1-10
Brand:suyuan
Origin:Made In China
Category:Electronics & Electricity / Electric Parts & Materials
Label:power meter , energy meter , meter testing
Price: -
Min. Order:1 pc

Product Description

Applications 

The system is used to calibrate various electronic and inductive three phase watthour meters, three phase multifunctional electronic meter, three phase multi-rate watthour meter and three phase prepaid watt-hour meter. It can be applied in positive and negative active, reactive four-quadrant test. With 3-wire and 4-wire real reactive reference standard, it is capable of calibration for various artificial reactive or real reactive watthour meter.

Functions and features 

(1) With special aluminum alloy housing, the device has firm and nice appearance. It is easy to operate and transport with light weight.

(2) Single phase power supply is convenient for users with various occasions.

(3) It has multiple protection system with high speed response, that makes the device more reliable. Also it has sound and light warning unit.

(4) Equipped with special keyboard, the device can indicate automatically the united unit and separated unit phase characteristics of all kinds of meters during user's manual verification, and it is more convenient

(5) As required by the protocol, automatic test can be carried out on watthour meter's startup, creeping, fundamental error, standard deviation, 8-hour and 24-hour variation. 

(6) High current output0~100A, convenient for calibration of high current watthour meter.  

(7) Impact test on watthour meter's voltage imbalance, frequency, harmonics , negative phase sequence, etc.

(8) It can test watthour meters with different constant, and correct the constant.

(9) Special junction box is employed to short circuit automatically in open circuit.

(10) Special photoelectric sampler is featured with automatic collection of mechanic meter black spots and electronic meter LED signals. Photoelectric head reverses by itself, easy to disassemble and assemble.

(11) Special pulse sampling interface and high voltage isolating circuit are adopted to avoid wrong switchin of high voltage.

(12) Meter running test can be performed according to KWh, time or pulse number.

(13) The real-time parameters, such as power, voltage, current, phase, power factor, frequency, etc. can be measured. The real time vector diagram can be displayed also.

(14) All types of bar code input is acceptable.

(15) With RS485 port, it is very convenient to connect with all kinds of foreign and domestic watthour meters.

(16) Automatic detection of communication protocol function is available.

(17) The communication protocol complies with all stipulations of DL/T645-1997 and IEC1107, and it can be modified as user's requirement.

(18) It has clock reference and GPS clock.

Other functions

With special connection and EMCS2002 meter calibration software, we can carry out tests for single phase multifunction and multi-rate watthour meters at a time without changing the connection. The following tests can be combined at random or be performed separately, conveniently and swiftly.

Daily timing error test

Time interval switching error test

Indicated value of demand error test (maximum demand)

Multifunction meter running test (meter running combined error test)

Various communication test

Meter address read and setting

Time interval and zone setting

Fit for single phase watthour meter(optional)

GPS broadcast timing

Register indicated value calibration (Register combined error test)

Demand circular error test

Constant calibration

Reading meter display data arbitrarily

Meter serial number reading and inspection

Various password and code verification and setting

Main technical specification

1.  Power supply: ~220V/16±10%,50HZ

2.  Device class: 0.030.050.1

3.   Voltage measuring range: 3×(100/3,100,220,380)V

4.   Current measuring range: 3×(0.05,0.1,0.25,0.5,1,2.5,5,10,25,50,100)A

5.   Voltagecurrent regulating range: 0~120%, regulating fineness0.002%;

6.   Three phase voltammeter accuracy: 0.1%,phase accuracy0.2°,frequency monitoring meter accuracy0.01HZ;

7.   Phase regulating range: 0°~360°,regulating fineness0.01°;

8.   Frequency regulating range: 45HZ~65regulating fineness0.001HZ

9.   Voltage loop capacity: 15VA per meter slot

10.  Current loop capacity: 500VA

11.  Output power stability: better than 0.02%/2min, voltage, current waveform distortion: better than 0.5%;

12.   Voltage symmetry:  0.1%; current symmetry: 0.1%

13.   ED455Gtime referencefrequency1HZ500KH HZTTL level),stability5×10-9/per dayaccuracy1×10-7

14.  Meter slot number of the system: 10