Ponovo PW460 Protective Relay Test Kit

Ponovo PW460 Protective Relay Test Kit
Model:PW460
Brand:PONOVO
Origin:Made In China
Category:Electronics & Electricity / Electric Control System
Label:protective relay , relay test , IEC61850
Price: -
Min. Order:1 pc

Product Description

Ponovo PW460 Protective Relay Test Kit 

PW460  (6x15A, 4x300V) is a comprehensive protection relay  testing equipment 

for all types of protective relays, including modern IEC61850 based relays. Other 

test works, such as transducer, energy meter, indication meter, etc., can also be 

done easily. It's  the ideal  test  device  for all  power  utilities,  power  plants,  relay 

manufactures,  panel  manufactures,  research  institutes,  universities,  testing 

companies, etc. 



Features
1. 6*15A, 4*300V
2. Aux DC (0-300V), DC measuring inputs
3. 8 binary inputs, 8 binary outputs, 4 counter inputs, 12 low level outputs
4. Adjustable threshold (0-400V) for binary inputs
5. In-built analog monitoring and recording function
6. Support IEC61850 based test
8. High accuracy
9. Current booster interface for testing high burden relay
10. Support importing setting value of relays via CSV/XRIO/RIO PONOVO's PowerTest default set files automatically into relay templates

 

In‐Built Analog Monitoring & Recording Unit 

This  in‐built  analog  monitoring  and  recording  unit 

samples  the  actual  current/voltage  outputs  and  real‐

time output waveform can be displayed in the software.  

This  makes  it  easy  to  check  the  correctness  of  wiring 

before  the  test and observe  the output during  the  test 

process. 

 

Real‐Time Outputs Display 

Real‐time  output  waveform  display  helps  the  fast 

troubleshooting of wiring and test circuitry before test 

actual started.  

User can also use this provision to analyze the external 

signals, such as phase angle, power, harmonic, etc. 

 

IEC 61850 Function 

PW460  provides  analog  voltage/current 

signal to relay and the GOOSE message from 

relay is  received and analyzed by  relay  test  equipment. 
 

Application

*Relay test 

Distance protection 

Differential protection 

Directional relay 

Time‐inversed current relay 

Auto‐reclosing, etc. 

*Measuring and control device 

Synchronizer 

Transducer 

Energy meter 

df/dt, etc. 

*System simulation 

Transient, steady‐state fault simulation 

Playback of COMTRADE format file 

*Calibration 

0.5 Class energy meter 

Disturbance recorder 

Indicating meters, etc. 

 

Main Specifications

Current

 

Range

6 x 0~15A

Power(typical)

6x 150VA at 15A

3 x 240VA at 30A

Accuracy (typical)

<0.08% rd+0.02% rg.guar., at 0~15A

Voltage

 

Range

4 x 0~300V

Power(typical)

4x 75VA at 300V

3 x 100VA at 300V

Accuracy (typical)

<0.08% rd+0.02% rg.guar., at 0~300V

Frequency

 

Sine signal

1 … 1000Hz

Transient signal

dc … 10.0kHz

Accuracy

0.3ppm

Phase angle

 

Range

-360°~+360º

Accuracy (typical)

0.05º

Auxiliary DC supply

0~300V

Power

88W at 110V, 176W at 220V,

90W at 300V

Binary input

 

Number

8

Type

0-400Vdc threshold or potential free

Counter input  
Number 4
Sample rate 20kHz

Binary output

 

Number

4

Type Relay
Number 4

Type

Semiconductor

Low level output

 

Number

12

Accuracy (typical)

0.025%

DC measurement

 

Voltage measuring

0…±10V

Current measuring

0...±20mA

IEC61850 GOOSE

optional

Dimension

360*157*367mm

Weight

20kg

 

PW460 can be used for various kinds of relay testing including:

IEEE. NO. DEVICE
2 Time Delay Starting or Closing Relay
21 Distance Relay
24 Volts per Hertz Relay
25 Synchronizing or Synchronism-Check Device
27/27N Undervoltage Relay
30 Annunciator Relay
32 Directional Power Relay
36 Polarity or Polarizing Voltage Devices
37 Undercurrent or Underpower Relay
40 Field (over/under excitation) Relay
46 Reverse phase or Phase-Balance Current Relay
47 Phase-sequence or phase-balance voltage relay
50/50N Instantaneous Overcurrent
51/51N AC Time Overcurrent Relay
52 AC Circuit Breaker
53 Field Excitation Relay
55 Power Factor Relay
56 Field Application Relay
58 Rectification failure relay
59/59N Overvoltage Relay
60 Voltage or Current Balance Relay
61 Density switch or sensor
62 Time-Delay Stopping or Opening Relay
64 Ground Detector Relay
67/67N AC Directional Overcurrent Relay
68 Blocking or "out of step" Relay
74 Alarm Relay
76 DC Overcurrent Relay
78 Phase-Angle Measuring Relay
79 AC-Reclosing Relay
81/81U/O/R Frequency Relay
82 DC load-measuring reclosing relay
85 Carrier or pilot-receiver relay
86 Lock-out relay
87 Differential Protective Relay
91 Voltage Directional Relay
92 Voltage and Power Directional Relay
94 Trip Relay
 

For more details of PW460 you can check https://www.ponovo.net/relay-and-protection-testing/protection-relay-testing-equipment-6i/pw460-protection-relay-test-set-is-the.html

Ponovo PW460 Protective Relay Test Kit 1Ponovo PW460 Protective Relay Test Kit 2Ponovo PW460 Protective Relay Test Kit 3Ponovo PW460 Protective Relay Test Kit 4

Member Information

PONOVO POWER CO., LTD
Country/Region:Beijing - China
Business Nature:Manufacturer
Phone:15101161396
Contact:Jennifer (manager)
Last Online:05 Jul, 2023