Chinese mini plam high resolution OTDR with different, different wavelength, dynamic range 24/32/35/37/38/40/42dB,event dead zone <1.6/2.5/3.0m, attenuation dead zone. Please choose the following module
Features
1.24/32/35/37/38/42/40dB high dynamic range, enabling extra-long distance measurement
2.0.1m sample resolution with 65535 sampling points
3.1.6m extra-short event dead zone
4.Large color LCD display, touch screen operation
5.High accuracy and stability
6.Auto measuring with high sped, one-button operation
7.Large internal memory for data storage
8.Write/read file in Bellcore GR196 file format
9.Intelligent battery capacity display
10.Battery operation life over 8 hours
11.Unique USB interface for connectivity and data storage
12.Attached with trace analyzing software, professional report can be generated immediately
13.Unique function of updating system online, returning to factory is unnecessary
Parameter
Item Specification
Distance range 1.6, 3.2, 8, 16, 32, 64, 128, 256, 512 (SM)
1.6, 3.2, 8, 16, 32, 64, 128 (MM-1300nm)
1.6, 3.2, 8, 16, 32 (MM-850nm)
Pulse width 10, 80, 160, 320, 640, 1280, 2560, 10240, 20480 (SM)
10, 80, 160, 320, 640, 1280, 2560, 10240 (MM-1300nm)
10, 80, 160, 320, 640, 1280 (MM-850nm)
Sampling resolution 0.1m~32m
Group refractive index setting 1.00000 to 2.00000, in 0.00001 steps
Vertical scale(/div) 0.1dB, 0.2dB, 0.5dB, 1dB, 2dB, 5dB, 8dB,
Resolution Sampling resolution: max 0.1m
Distance read-out resolution: 0.0001km
Loss read-out resolution: 0.001dB
Sampling points 65535
Distance accuracy ±(1m+sample space+ measurement distance x 0.01%)
(exclude uncertainty of fiber IOR)
Loss accuracy ±0.02dB/km(SM); ±0.2dB/km(MM)
Display 640x480, 7.7inch color LCD (touch screen)
Interface USB, RS232, Printer, Keyboard
Optical connector FC/UPC (universal connector, option)
Power supply DC:17~22V/3A;
AC adaptor: 100~240V/1.7A, 50~60MHz;
Built-in lithium battery: >8 hours;
Working environmental Operation temperature:0~50℃ (charging: 5~40℃)
Storage temperature: -40~70℃ (exclude battery)
Relative humidity: 5~95% RH (no condensation)
Weight 2.7kg
Application
FTTH, LAN, PON & Optical CATV
Local ring net
Optical fiber communication system
Optical fiber test equipment
Optical fiber sensor
More visit website: 3w(dot)adkoptic(dot)com or email to: adkoptic(at)adkoptic(dot)com.