PERMETM OX2/231 Oxygen Permeability Tester is applicable for the oxygen transmission rate determination of plastic films, laminated films, sheets as well as packages, like plastic bottles and pouches.
Characteristics
Mini-computer control; LCD displays data, results and curves;
Manu interface, PVC operation panel;
Aerage value of 3 chambers only;
Constant temperature control (optional purchase);
Constant humidity control (optional purchase);
Two testing modes of film and package (optional purchase);
Automotive power failure recovery;
Rapid calibration with reference film;
Mini-printer;
RS232 interface;
Network transmission interface for LAN data management and Internet data transmission.
Principle
Oxygen flows in one side of the film, and nitrogen flows on the other side. The oxygen molecules permeate through the film and into the nitrogen side, and are then carried to the sensor by the flowing nitrogen. By analyzing the oxygen concentration measured by the sensor, oxygen transmission rate and other parameters can be calculated. As to packages, nitrogen flows inside the packages, and oxygen flows outside the packages.
Technical Indexes
① Film Testing Technical Indexes
Test Range: 0.01~1000 cm3/m2·day
0.1~10,000 cm3/m2·day (optional)
Resolution: 0.01 cm3/m2·day
No. of Specimens: 1 to3 specimens.
Temperature Control Range: 15℃~55℃ (optional purchase)
Temperature Control Precision: ±0.1℃
Humidity Control Range: 0%RH; 15%RH~90%RH ; 100%RH (optional purchase)
Humidity Control Precision: ±1%RH
Specimen Size: 108×108 mm
Test Area: 50cm2
Test Gas: oxygen and air, etc. (users provide gas sources themselves)
Inlet Size: Φ4mm polyurethane pipe
Carrier Gas: high pure nitrogen with the concentration no less than 99.999% (users provide gas
sources themselves)
Inlet Size: 1/8 inch metal pipe
Power: AC (85~264) V (47~63) Hz
Dimensions: 670mm (L)×410mm(B)×310mm(H)
Net Weight: 48Kg
② Package Testing Technical Indexes (optional purchase):
Test Range: 0.0001~10 cm3/pkg·day (routine)
Resolution: 0.0001 cm3/pkg·day
Specimen body Sizes: 100% O2 Measurement: No less than Φ120 mm, and no higher than 360
mm.
Open Air Measurement: no size limitation.
No. of Specimen: 1~3
Specimen Specifications:
bottle—internal diameter of bottle mouth>φ8mm; external diameter of bottle mouth<φ42mm
(routine);
Pouch and box: supported by accessories;
Test Condition: ambient (standard condition: 23±2℃ 50%RH)
Humidity Control Range: 0%RH; 15%RH~90%RH ; 100%RH (optional)
Humidity Control Precision: ±1%RH
Test Gas: oxygen and air (users provide gas sources themselves)
Inlet Size: Φ4mm polyurethane pipe
Carrier Gas: high pure nitrogen with the concentration no less than 99.999% (users provide gas sources themselves)
Inlet Size: 1/8 inch metal pipe
Power: AC (85~264) V (47~63) Hz
Dimensions: 670mm(L)×410mm(B)×630mm(H)
Net Weight: 50kg
Standards:
ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 and GB/T 19789.
Configuration:
Standard: mainframe, mini-printer, software, nitrogen cylinder regulator, oxygen cylinder
regulator.
Optional: constant temperature controller, constant humidity controller, sealing accessories for package test; cover
Note: the gas inlet is 1/8 inch metal pipe and Φ4mm polyurethane pipe. Users provide gas sources themselves.