Attention:
1. The manual push rod at the end may be used during hydraulic system testing, with automatic reset functions.
2. For installation, use screws with a tensile strength of greater than 85kg/mm2 (Available at the time of purchase).
3. Inlet O-Ring must fully comply with Gb1325-76 Standards.
4. Remove the cover, tightenm it again after wiring to the base. There is a rubber ring at the cover wire entrance, when the threaded cover is tightened, wiring in the plug will be tightly clamped.
5. Cable must comply with explosion-proof requirements
Technical specification
Model dMFZ-37-MA dMFB-37-BT4 DTBZ90FYC-MAI
Rated Voltage DC: 12V. 24V. 48V
B: 48V(Input Voltage: 110VAC)
B: 99V(Input Voltage: 220VAC) DC: 12V. 24V
Rated Travel (mm) 2.8 2.8 4
Toal Travel (mm) 6 6 <9
Attraction Force (N) >37 >37 >90
Power (W) 22 22 36
Nominal Fluid Pressure (MPa) 10 10 21
Connection Dimension (mm) φ19? . 5 φ19? . 5 φ32?
Installation Dimension (mm) 35? 5 35? 5 49? 9
Application Under-well or on-the-
Ground inflammable,
Explosive locations On-ground inflammable,
Explosive locations
Pilots for proportional direction
Control valves, proportional
Press. Control valves in explosive
And inflammable location