Weighing Accessories Weighing Indicator Protocol

Weighing Accessories  Weighing Indicator Protocol
Model:XK3196G
Brand:goldshine
Origin:Made In China
Category:Electronics & Electricity / Electric Parts & Materials
Label:Weighing Indicator , Indicator Protocol , Weighing Accessories
Price: US $300 / pc
Min. Order:5 pc
Inquire Now

Product Description

1.The 9 pins of indicator 1,2:nothing;3,8,9:earth;  4:RS232 TXD;5:RS232 RXD; 6,7:large display data(TTL)

 

Indicator pins

4

5

3,8,9

 

Computer 9 pins

2

3

5

Short:4-6,7-8

Computer 15 pins

8

14

5

Short:5-7

Computer 25 pins

3

2

7

Short:4-5,6-10



2.Connection of indicator pins and computer pins 3.Indicator and computer communication Weighing indicator continual send the current weight data to computer, 7 bytes a suite: the first is start bit (&HCD),other 6 bytes means the 6 digits weight,as the follow rule:(PS:&H means hex)

Not display data------&H0A Display weight--------display "8",the byte is &H08,display"8.",the first is 1,namely &H88 Minus---------------&H0B Lock "L"-------&H11 (dynamic G indicator can lock the data, the first digit is"L",the code is &H11)

Example:

 

weight

1st byte

2nd byte

3rd byte

4th byte

5th byte

6th byte

7th byte

1234

&HCD

&H0A

&H0A

&H01

&H02

&H03

&H04

123.4

&HCD

&H0A

&H0A

&H01

&H02

&H83

&H04

-123.4

&HCD

&H0A

&H0B

&H01

&H02

&H83

&H04

L1234

&HCD

&H11

&H0A

&H01

&H02

&H03

&H04



Example Programme(VB) 'Receiving 13 bytes from RS232' dim ss as Variant dim i,j as integer dim tmpstr as string   ss = MSComm1.Input If LenB(ss) < 13 Then Exit Sub End If 'judge which byte the data start(algorism 205 is hex CD) While ss(i)<>205 and i<7 i=i+1 wend

'give up the data which has not 6 bytes after start bit if i>6 then exit sub

tmpstr="" for j=i+1 to i+6 If ss(j) <> 10 Then If ss(j) = 11 Then tmpstr = tmpstr & "-" ElseIf ss(j) > 127 Then tmpstr = tmpstr & CStr(ss(j) And 127) & "." Else tmpstr = tmpstr & CStr(ss(j)) End If End If next j

PS: the last tmpstr is the data that indicator sends to computer. 7 bytes is a weight data, the data is continually sent to computer, so this program gets 13 bytes every time to make sure there is one weight data. Customer can improve on it to match their requirement.

Weighing Accessories  Weighing Indicator Protocol 1

Member Information

Ningbo Goldshine Electronic Co., Ltd.
Country/Region:Zhe Jiang - China
Business Nature:Manufacturer
Phone:90250816
Contact:colin (manager)
Last Online:03 Jul, 2011

Related Products of this Company