Natural gas detector can work with auto shutoff valve, when gas leakage happen and the concentration of gas in the air achieve to a certain level, the detector will order the valve help you shutoff your gas pipe before you notice it.
1. MCU processing
2. High stability, energy-saving sensor
3. Wall Mounted
4.Independent & Network Optional
5. Power Input Method Optional
6. Auto Reset After Alarm
Electromagnetic Valve
1. Rated voltage:DC 9V
2. Closing Method:AC bluse closing
3.Valve compress:0.1Mpa
4.Closing time:≤1S
5.Size:103*64*47mm
Technical parameter
1. Induced Gas: Natural Gas
2. Power Input: AC 220V 50Hz Or DC 12V
3. Buzzer Level: ≥70dB/m
4. Alarm Density: 15% LEL
5. Working Temperature: -10℃ to + 40℃
6. Working Humidity: ≤90% RH
7. Alarm Density Error: ±5% LEL
8. Alarm Mode: Flash & sound alarm /Shut off Gas Valve/ Network Alarm Signal
9. Power Consumed: ≤5W
10. Size: 120 * 70* 44mm