12.1" Patient Monitor ICU Monitor NIBP RESP SPO2

12.1" Patient Monitor ICU Monitor NIBP RESP SPO2
Model:RPM-9000A
Brand:Risingmed
Origin:Made In China
Category:Electronics & Electricity / Other Electrical & Electronic
Label:Patient Monitor , ICU Monitor
Price: US $950 / pc
Min. Order:1 pc
Inquire Now

Product Description

Features:   
  • Ergonomic design, portable, convenient for use
  • 12.1" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
  • Unique digital SPO2 technology can work accurate during motion and low perfusion
  • Anti AC & high-frequency electrosurgical & defibrillators interference
  • Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
  • Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
  • ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
  • Audible & visual alarm available, adjustable
  • Patient information management function
  • Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
  • Flexible data storage & transfer/software upgrading based on USB
  • Wired/wireless networking with central monitoring system, up to 64 beds in one group
  • Built-in 3 trace thermal recorder for printing real-time and historical data
  • Multi-language i.e. English, Spanish, French, Italian, Turkish, German, Russian etc.
  • Super long life rechargeable dual lead-acid battery (optional) upto 4 hours of working time
  • Suitable for adult, pediatrics and neonate patients
Standard configuration:            
  • ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable lead-acid battery
Optional:            
  • Dual TEMP
  • Dual IBP
  • ETCO2 (side stream) 
  • Thermal recorder
  • Wall mount
  • Trolley
Specification:
 
 
ECG
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate: 
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period. 
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.   
Accuracy: Error rate < 20%         
Undetected rate < 20% 
ST section 
Scope:     ±0.8mV
Precision : 
±0.05mV
SpO2
Detection scope:   0%-100%
Accuracy         ±1%     90%-100%               
                 ±2%      70%-89% 
NIBP 
Theory Electric oscillator 
Cuff gassing time   less than 15 seconds
First-time gassing pressure: dynamic state 24kPa
180 mmHg
Manual selection: 9.3kPa
70 mmHg),13.3kPa100 mmHg),16.0kPa120 mmHg
18.6kPa
140 mmHg),20.0kPa150 mmHg),21.3kPa160 mmHg),
Automatic detection period: 1 minute to 240 minutes 
Stop size
1 min1 min -10min, 5min(10 min -30min), 10min(30 m
in -90min) and 30min
90 min -240min
Detection scope: 
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa
31.3kPa       20mmHg235mmHg
Detection accuracy 
Static pressure: ±3mmHg
Pulse rate:  ±2%
Resp
Chest impedance method or concentration of carbon dioxide at end of respiration 
Scope of chest impedance method     0 time/minute – 100 minutes/minute 
Precision of chest impedance method  time/minute 
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg
0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute
including baby
Detection precision of respiration rate: ±1 time/minute 
Temp
Single/double path 
Type:    Vascular/surface temperature 
Scope:    20
50
Accuracy:  ±0.2
Invasive blood pressure (optional)
Single/double path 
Type: direct and continuous detection 
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
Pa(100mmHg) above ±2%
Frequency response
DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage
5V (DC)
Accuracy of sensor: ±2
Isolation voltage: 4 kV
12.1" Patient Monitor ICU Monitor NIBP RESP SPO2 112.1" Patient Monitor ICU Monitor NIBP RESP SPO2 212.1" Patient Monitor ICU Monitor NIBP RESP SPO2 3

Member Information

Beijing Risingmed medical company
Country/Region:Beijing - China
Business Nature:Manufacturer
Phone:15101596603
Contact:Anita Liu (Sales )
Last Online:08 Nov, 2011