Overview
 Variable Electrical Engineering GBTSC series of dynamic reactive power compensation device for filtering nonlinear loads such as thyristor, inverter, electric arc furnace as a result of excessive harmonic current, low voltage power factor power system.

    
 
Overview
 Variable Electrical Engineering GBTSC series of dynamic reactive power compensation device for filtering nonlinear loads such as thyristor, inverter, electric arc furnace as a result of excessive harmonic current, low voltage power factor power system.
Real-time tracking controller load fundamental power factor, reactive current, and pre-set reference value for comparison, the dynamic control of the number of switching filter capacitors of different groups to ensure that the power factor is always to meet the set requirements. As sampling is the fundamental parameters, the controller can compensate for the amount of accurate and reliable, and dynamic non-contact capacitive switch components imported from Germany, SCR zero trigger switching capacitance to ensure no impact, no flow, no transition process. Fast-track the load changes, to overcome the traditional reactive power compensator on the life of the capacitor and its own inherent flaws.

  

‍Main technical parameters:

 1. may compensate, but also focus on compensation;

 2. the implementation of three-phase or phase dynamic compensation, A model for symmetrical load, W is suitable for asymmetric load or impact load;

 3. Real-time tracking fundamental parameters, dynamic reactive power compensation to achieve no impact, no flow, no transition process switching;

 4. dynamic harmonic suppression, safe and reliable operation;

 5. reduce network losses and transformer losses, increased load capacity of the transformer;

 6. suppress voltage flicker;

 7. In the external fault or stop automatically when launched, automatically resume operation after power transmission;

 8. microcomputer control, intelligent optimization mode switching to achieve unattended, and has a serial communication function;

9. to achieve zero current switching, capacitors maximize the service life;

 10. the provisions of the dynamic response time, multi-level compensation first place, the compensated power factor greater than 0.90

 11. meet the standards: IEC831-1, GB12747-91

 12. Dynamic Response time: <20ms

 13. Compensation Capacity: (kvar): 90-810 (single set of capacity), you can use multiple sets and

 14. Switching Series: Grade 2-11 ..

 15. enclosure protection class: IP30

 16. The total power consumption: <1.3W/kvar

 17. allowable error: 0 ~ +10%

 18. Ambient temperature: -30 ゜ C - +50 ゜ C

 
 

Scope and conditions:

 1. load power factor is low, line voltage drop is large, the need for reactive power compensation of the occasion;

 2. in the load power factor range from large, fast changes in the occasion;

 3. compensation of voltage fluctuations and dynamic places with higher requirements for electricity;

 4. widely used in electricity, machinery, cars. Metallurgy, shipbuilding, port operation. Railway. Coal, chemical, oil and other industries;

 5. Ambient temperature: 0 ~ 40 ° C; Storage Transport Temperature: -25 ~ 45 ° C;

 6. Relative Humidity: 0 ~ 85% non-condensing;

 7. Altitude: <2000m;

 8. Ground gradient: ≤ 5 °;

 9. the installation site without fire, explosion, no chemical corrosion and severe vibration;

  Note: If the special environment conditions of use, please state when ordering and consultations with our company;

 
 

 Wiring; ..


Ordering Information:.

 When ordering, please provide the following information:

 > system harmonic current components and content;

 > device, into point voltage distortion;

 > need to compensate for reactive capacity, transformer capacity and the percentage of short-circuit impedance;

  Note: If the user needs, users can power the necessary measurements and provide a complete solution.

 Complete sets of working in Nanning, Guangxi Electric Co., Ltd. product changes in the origin of a wide range of professional, excellent performance, and accumulated a wealth of case management, providing complete product solutions. Please provide your plant single line diagram for the application of specific electrical parameters, we will provide you with complete design and perfect service.
 

Filter dynamic reactive power compensation   ‍GBTSC 1Filter dynamic reactive power compensation   ‍GBTSC 2Filter dynamic reactive power compensation   ‍GBTSC 3

Member Information

GUANG XI NAN NING GONG BIAN ELECTRIC CO.,LTD
Country/Region:China
Business Nature:Manufacturer
Phone:13807888616
Contact:John chen (Major clients Manage)
Last Online:11 Sep, 2013