AVAILABLE FLOOR OPTIONS Web Joist Floor Systems-49
Product Description
After finishing the installation of floor, it goes to the upper structure. Even there is concrete, it doesnt affect other structure and the installation of cladding material. Along with BFS specialized floor supporting system, it achieves excellent acoustic and insulation performance.
- - - -
DeadLoadsUsedforDesign | | | |
LoadType | | SubTotal(kpa) | TotalLoad |
SheetRoof | 0.48mmSheet | 0.08 | |
OSBCladding | 0.06 | |
Accessories | 0.06 | 0.20kpa |
TileRoof | TerraCottaTiles | 0.56 | |
OSBCladding | 0.06 | |
Accessories | 0.1 | |
Total | | 0.72kpa |
TrussSelfWeight | | | 0.06kN/m |
CeilingWeight | Plasterboard | 0.1 | |
Accessories | 0.06 | |
Total | | 0.16kpa |
FloorSelfWeight | FloorFraming | 0.12 | |
FloorSheeting | 0.15 | |
Accessories | 0.22 | |
Total | | 0.49kpa |
WallSelfWeight | Plasterboard | 2x0.13 | |
WallWeight | 0.08 | |
OSBCladding | 2x0.06 | |
Accessories | 0.02 | |
Total | | 0.48kpa |
- - - -
- - - -
RoofSnowLoad | |
Location | Load |
IntermediateRoofSnowLoad | 0.00kpa |
0.85kpa |
EaveSnowLoad | 0.00kpa |
1.20kpa |
- - - -
- - - -
BasicWindSpeedsandFactors | |
Item | Load |
PermissibleWindSpeed | 40and45m/s |
DesignWindPressurefor40m/s | 0.864kpa |
DesignWindPressurefor45m/s | 1.093kpa |
Externalroofcoefficients | -0.90, +0.40 |
Internalroofcoefficients | +0.20, -0.30 |
Externalroofcoefficientsateaves | -1.8 |
Internalroofcoefficientsateaves | 0.2 |
Externalwallcoefficients | 0.7 |
Internalwallcoefficients | -0.3 |
Externalwallcoefficientsatcorners | -1.3 |
Internalwallcoefficientsatcorners | 0.2 |
- - - -