Germany IMPLEN spectrophotometer Nanogram

Germany IMPLEN spectrophotometer Nanogram
Model:NanoPhotometer
Brand:Germany IMPLEN
Origin:Made In Germany
Category:Electronics & Electricity / Electronic Instrument / Analysis Instrument
Label:IMPLEN , Nanogram spectrophot , Spectrophotometer
Price: €9000 / pc
Min. Order:1 pc

Product Description

Germany IMPLEN ultra exclusive spot sales volume spectrophotometer Beijing analyzer trace of nucleic acid protein
Type: NanoPhotometer Pearl Tel: 86-10-59465921 52528878
The photometric instrument designed to provide maximum flexibility, to be completed by volume of the sample and the constant micro sample testing, the use of a large work function of the software, you can create for their own methods, you can also use a good program analysis has been prepared to meet the needs of a variety of uses. Analyzer can be single-wavelength, multi-wavelength, and dynamics testing, full-range 190-1100nm wavelength scanning. NanoPhotometer Pearl only 0.3 to 2 ul test sample added to the test surface directly, without using a cuvette and capillary, do not waste samples, but also reduces consumables (disposable cuvette) of the cost. Measurement results can be stored for later retrieval call. Do not dilute the sample, eliminating the cumbersome repeated correction, dilution, concentration conversion, etc. duplication of work
Ultra volume solution samples
Photometric Range: 190 - 1,100 nm wavelength scanning: 200 - 950 nm scan time: 3.5 seconds Wavelength reproducibility: <± 0.2 nm wavelength accuracy: ± 2 nm bandwidth: better than 5 nm
Stray light: <0.5% (at 220 nm and 340 nm with NaNO2) Photometric range: -0.3 - 2.499 A 0-199 T
Photometric Repeatability: ± 0.003 A 0 to 0.5 A ± 0.007 A 0.5-1.0 A @ 260 nm Photometric accuracy: ± 0.005 A or ± 1 of the reading, whichever is the greater
Baseline Stability: ± 0.003 A / h 340 nm, 20 minutes
Noise level: 0.002 A rms at 0 A @ 260 nm 0.005 A pk to pk at 0 A
@ 260 nm
Optical system: dual-channel Czerny-Turner grating, 1024 pixel CCD array, concave mirror
Light Source: Xenon lamp life of up to 10 years Warranty: 2 years performance verification: automatic diagnostic boot open
Sample pool Type: Center Height: 15 mm, external dimensions: 12.5 × 12.5mm tube storage: 8 x 10mm optical path cuvette Metering mode: total absorption, transmission, concentration, wavelength scanning, the proportion of multi-wavelength, dynamics, ABS x factor / min
Storage: the user can store up to 81 built-in method of approach: nucleic acid microarray labeling efficiency, protein and cell density display format: 320 x 240 pixels
Size: 140 mm x 275 mm x 380 mm
Weight: <4.5 kg
Voltage :90-250 V, 50/60 Hz, Max 30 VA
Input / output ports: USB or Bluetooth connection to PC, download the form data directly calculate, print and data storage
 







NanoPhotometer? Micro photometer 86-10-59465921 52528878
 
First, the complete solution, to be completed by volume of samples and constant ultra test samples
 
NanoPhotometer? In photometric design to provide maximum flexibility, to be completed by volume of the sample and the constant micro sample testing, the use of a large work function of the software, you can create for their own methods, or use a good program analysis has been prepared to meet the the use of different needs, you can enter a single wavelength, multi-wavelength, and dynamics testing, can be full range 190-1100nm wavelength scanning.
 
Second, the outcome as long as 20 seconds without the use of cuvettes and capillary
1. Directly pipette samples will be tested only 0.7 to 10? L increase in the detection of the surface without the use of cuvettes and capillaries. Do not waste samples, saving consumables (disposable cuvette) costs;
 
 
2. Close the cover
 
3. Start measuring, and storing measurements for later retrieval call. Do not dilute the sample, eliminating the cumbersome repeated correction, dilution, concentration conversion, etc. duplication of work. Accelerate the detection speed can be obtained directly purity data.
 
4. Cleaning measurement window, which can effectively prevent cross-interference between the sample and the sample residue accumulation.
 
5. Wipe samples cover, photometer to the next sample can be measured
 
 
Third, the advanced technology
1.The NanoPhotometer? Is a simple to use UV / visible spectrophotometer is widely used in molecular biology, biochemistry and microbiology.
CCD array detector (1024 pixels) and the pulse xenon lamp, to ensure the most accurate measurement.
:190-1100 nm wavelength range
Wavelength Repeatability: ± 1 nm
Accuracy: ± 2 nm
Spectral bandwidth: 5 nm
Photometric range: - 0.3 to 2.5Abs,
2. The samples were drawn on the center of the measuring window, do not dilute the sample, eliminating the cumbersome repeated correction, dilution, concentration conversion, etc. duplication of work. Accelerate the detection speed can be obtained directly purity data.
 
 
 


















 
Nanophotometer Features
 
Technical parameters:
Luminosity range of 190 - 1,100 nm
Wavelength scan 200 - 950 nm
Scan time of less than 5 seconds
Wavelength reproducibility <± 0.2 nm
Wavelength accuracy of ± 2 nm
Bandwidth of better than 5 nm
Stray light <0.5 (at 220 nm and 340 nm with NaNO2)
Luminosity range -0.3 - 2.499 A 0-199 T
Photometric repeatability of ± 0.003 A 0 to 0.5 A
± 0.007 A 0.5-1.0 A @ 260 nm
Photometric accuracy of ± 0.005 A or ± 1 of the reading, whichever is the greater
Baseline stability of ± 0.003 A / h 340 nm, 20 minutes
Noise level 0.002 A rms at 0 A @ 260 nm
0.005 A pk to pk at 0 A @ 260 nm
Dual-channel optical system Czerny-Turner grating, 1024 pixel CCD array, concave mirror
Xenon Light Source
Life of up to 10 years
1 year warranty
Performance verification boot open automatically diagnose
Cell types center height: 15 mm, external dimensions: 12.5 × 12.5mm
Vitro storage capacity is 8 10 mm cells
Metering mode absorption meter, transmission, concentration, wavelength scanning, the proportion of multi-wavelength, kinetics, ABS x factor / min
Storage can store up to 90 user methods
Built-in method of nucleic acid microarray labeling efficiency, protein and cell density
Display Format 320 x 240 pixels
Size 140 mm x 275 mm x 380 mm
Weight <4.5 kg
Voltage of 90-250 V, 50/60 Hz, Max 30 VA
Input / output port USB or Bluetooth connection to PC, download the form data directly calculate, print and data storage
 
  
1. 0.7ul only sample testing for the detection of a trace amount of samples; is the minimum sample size required to market the product.
2. Pipette directly added to the detection of the test sample surface, without the use of cuvettes and capillaries. Do not waste samples, saving consumables (disposable cuvette) costs;
3. Does not require dilution of the sample, eliminating the cumbersome repeated correction, dilution, concentration conversion, etc. duplication of work. Accelerate the detection speed can be obtained directly purity data.
4. Full wavelength scan ,190-1100nm.
5. Scanning speed, a full wavelength scan only 5s. NanoDrop faster than doubled.
 
If the optional standard cuvette spectrophotometer to complete the test sample constant.
6. Nucleic acid sample measurable range: 15ng/ul-4000ng/ul, protein samples of the measurement range 0.2mg/ml-100mg/ml, to meet the needs of your daily experiment.
7. The instrument itself can bring their own printer, you can also transfer data via Bluetooth to the computer components, you can print out the data in real time.
Display: backlit LCD display
Germany IMPLEN spectrophotometer Nanogram 1Germany IMPLEN spectrophotometer Nanogram 2

Member Information

Technology & Trade Co., Ltd. Beijing Central Run
Country/Region:Beijing - China
Business Nature:Trading Company
Phone:13810792538
Contact:jie wang (Sales Manager)
Last Online:27 Dec, 2012