Manufacturers power supply ship compass converter

Manufacturers power supply ship compass converter
Model:GC-2000
Brand:Wanstar
Origin:Made In China
Category:Transportation / Vessel Parts
Label:Gyrocompass conversi , Instrument
Price: ¥900 / pc
Min. Order:1 pc
Inquire Now

Product Description

GC-2000 manual compass converter

 

 

Welcome to GC-2000-type compass converter (Gyro converter Digital), before you use, carefully check the box packaging items are complete.

List of items as follows:

1. GC-2000 hosts a

2. GC-2000 compass converter using a manual

3. Input and output plugs in a row

4. A set of mounting screws

 

 

TABLE OF CONTENTS

 

 

1. Overview ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...

 

2. Technical parameters ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...

 

3. General methods of operation ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...

 

4. Troubleshooting ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...

 

5. Installation ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...

 

 

 

First, an overview

 

GC-2000-type compass converter: the traditional gyro compass can be synchronous or stepper analog signals into digital signals, and real-time display heading data, while providing multi-standard signal supply radar, autopilot, electronic charts, AIS, etc. equipment.

 

Second, the technical parameters

(A), the general parameters

① 4-digit LED display heading, display accuracy of 0.1 degrees, adjustable brightness.

 

② can be applied to a variety of synchronous or stepper compass, to adapt to mass ratio: 360X, 180X, 90X, 45X, 36X.

 

③ Power supply:

Can not receive external power, set the switch as long as the match with the compass to work correctly.

When the AC synchronous compass, compass excitation voltage from the power supply;

Then step compass, the power from the step signal.

④ Power: <5W.

⑤ Operating Temperature 0 --- +70 degrees.

⑥ Storage Temperature: -40 ----- +85 degrees.

⑦ Weight: 600g

⑧ Output Accuracy: synchronous and stepper with 360X compass at: 0.2 °

⑨ can detect angular velocity range heading: synchronous and stepper with a 360X compass time: not less than 10 ° / sec

⑩ Dimensions: 170mm х 150mm х 45mm

 

(B) the input signal

1, synchronous compass:

Excitation voltage: AC 50 ~ 120V, 50/60/400/Hz

Phase voltage: AC20 ~ 110V

Transmitted to the ratio: 360X, 180X, 90X, 45X, 36X

    

2, step compass:

Common polarity: Total Positive / Negative common

Phase voltage: DC 24 ~ 100V

Transmitted to the ratio: 360X, 180X, 90X, 45X, 36X

    

(C) output signal

GC-2000-type compass converter output NMEA0183/IEC61162-1 standard data transmission protocol defined by the HDT statement.

Statement format is:

$ ** HDT, xxx.xx, T * hh (4800,8, N, 1)

Output Baud Rate: 4800

Data bits: 8

No parity: N

Stop Bits: 1

HDT statement sent Frequency: 4 per second

 

Heading data transmission format:

(1) RS422 bus

Output current:> 50mA, can be directly driven at least 8 standard IEC61162-2 input.

(2) RS232 bus

Output current greater than 10mA, can drive two standard RS232 input port.

(3) AD-10 Output: Output in Japan Furuno proprietary format.

 

Third, the general methods of operation

 

1, the proper use of the compass to set the following three types of selector switch, compass work only to get power.

(A) synchronous / stepping switch

(B) the total positive / total negative switch

(C) the transfer switch to the more than

 

                               
SYNC STEP

Synchronization when connected compass:

 

              
Ten SYNC STEP-C0M + COM

Positive steps were connected when the compass:

 

                               
SYNC STEP-C0M + COM

Received a total of negative-type stepping compass when:

 

                         

2, set the compass to transfer more than

 

The table setting switch SW1-1, SW1-2, SW1-3, SW1-4 with the same compass, GC-2000 in order to properly display and transmit heading signal.

 

SW1-1/SW1-2/SW1-3/SW1-4
 
Synchronous compass
 
Step compass
 
360X
 
ON OFF OFF OFF
 
OFF OFF OFF OFF
 
180X
 
ON OFF OFF ON
 
OFF OFF OFF ON
 
90X
 
ON OFF ON OFF
 
OFF OFF ON OFF
 
45X
 
ON OFF ON ON
 
OFF OFF ON ON
 
36X
 
ON ON OFF OFF
 
OFF ON OFF OFF
 

 

Factory setting: When the GC-2000 products factory set: synchronous compass; transmitted to the ratio: 360X

Note: When you need to set the compass to the type selector switch or pass over the switch, please cut off the compass input signal.

 

3, wiring methods:

(1), input line (R1, R2, S1, S2, S3, COM) terminals corresponding to the gyro compass:

① If the number Step Luo Jingxin input signal should terminals S1, S2, S3, COM access to compass the corresponding signal. R1, R2 is vacant, do not take.

② If the input signal synchronization Luo Jingxin number, put the terminals S1, S2, S3 access to compass the corresponding signal, R1, R2 access excitation voltage, COM is vacant.

③ compass does not know the type, technical specifications, please check the compass.

④ found compass heading displayed in the main compass directions and change the heading direction changes in the opposite direction, you only need to S1, S2, S3 in the swap any two lines can get the correct direction of change.

 

(2), the output lines (422A, 422B, 232H, 232C, CLK-H, CLK-C, DATA-H, DATA-C) terminal:

① Output RS-422 signal: RS-422A, RS-422B

② Output RS-232 signal: RS-232H, RS-232C

③ Output AD-10 signals: DATA-H, DATA-C, CLK-H, CLK-C

 

Common type of compass, such as the transmission to the next:

 

Manufacturer
 
Model
 
Compass type
 
Transmitted to more than
 
Remarks
 
Anschutz
 
Standard2, 3,4,6,12
 
AC synchronous
 
360X
  
 
ST14-GYROSTAR, Standard20
 
Step

Total Negative
 
180X
  
 
Yokogawa

Navtec

(Plath type)
 
C-1/1A/2/3, A-55, B-55, C-1JR

CMZ-100/200/300, D-1Z/1/3IPS-2/3
 
AC synchronous
 
360X
  
 
CMZ-50
 
Step

Total Positive
 
180X
  
 
C. Plath
 
NAVGATII, III
 
AC synchronous
 
360X
  
 
HOKUSHIN
 
C1, C2, C3
 
AC synchronous
 
360X
  
 
KAWASAKI
 
GX-81
 
AC synchronous
 
90X
  
 
SPERRY TYPE

(Tokimec)
 
ES-1/2/11,

GLT-101/121/103/106K/107
 
AC synchronous
 
36X
  
 
ES-11A/110, TG-200, PR222R/2000,

PR237L / H, GM-11, GM-21
 
AC synchronous
 
90X
  
 
MK-14, MOD-1/2/T, NK-EN, NK-E1
 
Step

Total Negative
 
180X
  
 
TG-100/3000/5000, ES-17, PR-357/130/140,

GLT-201/202/203
 
Step

Total Positive
 
180X
  
 
SPERRY
 
SR120, SR220, MK20, MK37/MOD-1
   
Step

Total Positive
 
90X
  
 
ARMABROWN
 
MK-10, MKL-1, SERIES1351, MOD-4
 
Step

Total Positive
 
180X
  
 
ROBERTSON
 
SKR-80
 
Step

Total Negative
 
180X
  
 
441,442,455
 
DH-2, DH-2G, HH-3, CPL-1
 
AC synchronous
 
360X
  
 

 

 

4, methods of operation

 

[A], GC-2000 operation panel has three buttons, namely, * key, ▲ up, ▼ down.

 

The first step, by way of the power supply switch set the type of compass, compass according to the type of pass to set up than the switch.

The second step, connected output lines RS422, RS232, AD-10

The third step, the input signal line access compass S1, S2, S3, COM (step compass), or S1, S2, S3, R1, R2 (synchronous compass). Digital display flashes.

The fourth step, heading correction, up by ▲, ▼ keys down, adjust the display's main compass heading data and the point to the same.

The fifth step, press the * key once to display figures do not blink. At this time GC-2000 can be synchronized with the main display the correct compass heading data.

 

The sixth step, compass display settings:

When the flicker-free display heading data, click on the * key, shows, in order to set the compass is now transmitted to the type and ratio: Sync ---- synchronization StEP ---- Step Rnnn --- r than that transmitted to , nnn said the three digits, respectively, 360x, 180x, 90x, 45x, 36x.

 

Seventh step, adjust the bow to the display value:

When they find GC-2000 with the main compass display data does not match, the data need to be adjusted to match the display.

1, hold down the * key for about 3 seconds, the display flashes heading value.

2, up by ▲, ▼ key to adjust the displayed value down.

3, when the value of the main compass directions with the same, click the * key to complete the match.

 

Eighth step, adjust the display brightness:

When the GC-2000 bow to the normal display, press the ▲ button up the brightness increases, according to the brightness decrease ▼ keys down.

 

 

 

 

 

 

Fourth, Troubleshooting

 

No.
 
Symptom
 
Possible Cause
 
Approach
 
1
 
Flashing "E nn"
 
Not initialized
 
Use ▲ and ▼ keys to adjust the bow to the data, after a good tune in 60 seconds, press the * key to confirm.
 
2
 
Flashing "A nn"
 
Transmitted to the error than the set

AC synchronous input signal broken compass

 
 
Check the settings and connections
 
3
 
No display
 
Compass is not turned on
 
Open the compass
 
4
 
Blown fuse
 
Check the voltage is normal compass
 
Replace the fuse
 
5
 
Show changes in the opposite direction
 
Compass phase wiring error
 
The S1, S2, S3 swap any duplicitous line
 
6
 
Show different rates of change
 
Transmitted to the switch and compass than the different types of
 
Reset transmitted to more than
 
7
 
No data output
 
Output terminal loose

Data lines connected anti-

Input data receiving equipment failure
 
Check terminal

Check the wiring is correct

Check the equipment connected
 

 

 

Fifth, equipment installation

 

     
GC-2000 Dimensions (unit mm)

Manufacturers power supply ship compass converter 1Manufacturers power supply ship compass converter 2Manufacturers power supply ship compass converter 3

Member Information

Guangzhou Xinzhu Electronic Equipment Co.Ltd
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:18024555510
Contact:hebihong (Sales manager )
Last Online:03 Jan, 2014