Thermal shock test chamber |
|
|
MS-CJ-50C |
MS-CJ-100C |
MS-CJ-200C |
MS-CJ-300C |
Interior capacity(L) |
50 |
100 |
200 |
300 |
System |
2-zone or 3 zone system by means of damper switching |
Performance |
High temp. Chamber |
Pre-heat temp. Range |
+60℃~+200℃ |
heating time※1 |
A+60℃→+200℃≤20min |
Low temp. Chamber |
Pre-cool temp. Range |
-78℃~0℃ |
Cooling time※1 |
A+20℃→-75℃≤70min |
A+20℃→-70℃≤80min |
Test chamber |
Temp. uniformity |
±2℃ |
Temp. Range |
A-65℃~+150℃ |
A-55℃~+150℃ |
Temp. Recovery time※2 |
Within 5 minutes※3 |
Within 5 minutes※3 |
Within 5 minutes※3 |
Within 5 minutes※3 |
Speciment capacity |
30kg |
Speciment weight |
2.5kg |
7.5kg |
10kg |
7.5kg |
Interior dimension(mm) |
W |
410 |
650 |
650 |
970 |
H |
460 |
460 |
460 |
460 |
D |
370 |
370 |
670 |
670 |
Exterior dimension(mm) |
W |
1470 |
1710 |
1710 |
2030 |
H |
1800 |
1800 |
1800 |
1800 |
D |
1570 |
1570 |
1870 |
1870 |
Utility requirements |
Temp.:+5℃~+35℃;Humidity:≤85%RH;Atmospheric pressure:86~106kPa |
Material |
Enclosure |
Galvanized steel plain Sheet color coated |
Interior |
Stainless steel plate SUS304 |
Thermal insulant |
Hard urethane foam + glass wool |
Construction |
High temp. Chamber |
Heater |
Nichrome Electronic Heater |
Fan |
Centrifugal fan for High, ambient temperature.axial flow fan for pre-heating. |
Low temp. Chamber |
Heater, condenser |
Nichrome Electronic Heater、condenser、Regenerator |
Fan |
Centrifugal fan |
Drivers |
Air cylinder |
Drive the ventilation door |
Air compressor |
Provide compressed air to drive the air cylinder (Optional) |
Refrigerator unit |
Refrigeration mode |
Mechanical cascade refrigeration system(water cooled) |
Refrigerating Compressor |
Semi-closed refrigerating compressor |
Refrigerant |
R404a/R23 |
Condenser |
Stainless steel brazed plate heat exchanger |
Controller |
Displayer |
86.37(Height)×115.17(Longth)mm,LCD |
Running mode |
Program operation |
Setting |
Touch panel method |
Program capacity |
32 patterns, 3 steps max. per pattern, 999 times max. cycling. |
Setting range |
High temperature upper limit:220℃;Low temperature limit:-80℃ |
Test chamber:Shock upper limit+10℃,shock lower limit-10℃ |
Display resolution |
Temp:0.1℃;Time:0.1min |
Input |
thermocouple |
Control mode |
PID control;BTC Blanced Temperature control |
Power supply |
AC380(1±10%)V (50±0.5)Hz three-phase four-wire+ protection ground wire |
Power(KW) |
38 |
36 |
36 |
36 |
Weight(kg) |
1430 |
1480 |
1420 |
1530 |
Cyclic cooling water |
Water pressure:0.25~0.4MPa, Water temperature:≤30℃ |
Compressed air |
0.5~0.7MPa |
Standard accessories |
Test chamber status indicator 1pc,time recorder 1pc,cable hole(Φ40)1pc,Casters with adjusters. |
Safety devices |
Leakage breaker,Interior over heat protector,Fan over heat protector,Compressor over heat protector,Compressor over pressure protector,Speciment over heat protector,power supply protector |
※1 Heating time and cooling time is measured under high temperature chamber or low temperature chamber working only. |
※2 Recovery condition: Ambient temperature is +25℃ and cycling water temperature +25℃ |
|
High Temperature chamber |
Low Temperature chamber |
Sensor position |
※3 Recovery time for high and low temperature chamber |
(+150℃:30minutes) |
(-65℃:30min) |
Upper side of speciment |
Remarks: Above data maybe changed without notice. |