permanent magnetic actuator

permanent magnetic actuator
Model:YCG
Brand:GUANGZHOU GUONENG AUTOMATIC CONTROL TECHNOLOGY
Origin:Made In China
Category:Electronics & Electricity / Other Electrical & Electronic
Label:permanent , magnetic , actuator
Price: ¥8000 / pc
Min. Order:1 pc
Inquire Now
点击这里给我发消息

Product Description

permanent magnetic actuator

Permanent magnet switch to maintain permanent magnetic actuator

 

My company research and development of permanent magnetic actuator YCG, spring operation to replace the original, has been developed for domestic dozens of switch technology mature, reliable, permanent magnet driven machinery supporting ZW, zinc, VMS type, such as all kinds of vacuum circuit breaker, widely used in electric power, coal, steel, oil, railways and other systems. 
advantages

 

During the whole life, maintenance free

Long-life electrical and mechanical, long service life

Ability of fast coincidence

Type, suitable for installation in a variety of tank (such as fixed cupboard, handcart cupboard)

Operation, power supply range

Easy to compatible with SCADA

Low power consumption,

Small volume, light weight

 

My company's permanent magnetic operating mechanism because of the very few movement part, cancelled the complicated mechanical lock and tripping system, thus has irreplaceable advantages: less faults, reliable, long life (can reach more than 100000 times), no lubrication, very suitable for some requiring high reliability, frequent operation, such as electricity, coal, steel, railway, etc.

Use my company's permanent magnetic operating mechanism, cooperate with our company YCK380 series permanent magnet switch controller, can realize the points and closing operation of circuit breaker, velocity of fault protection, loss of pressure protection, wireless remote control, reclosing operation, as well as the distribution network automation function, make the switch intelligent circuit breakers.

Note:

1, do not advocate use simple contactor to permanent magnetic actuator as control unit, because:

(1) using the contactor can lead to large energy consumption and discharge capacitance requires a larger capacity;

Permanent magnetic actuator (2) easy to burning coil;

(3) the contactor off contact circuit generates a strong electromagnetic interference, cause protection misoperation, control device;

(4) the contactor of contact when through the large current, life is short, so there was not one of the major advantages of permanent magnetic actuator. And my company YCK380 permanent magnet switch controller can reach more than 100000 times is not damaged.

2, about the manual of permanent magnetic actuator, closing question: brake must be equipped with emergency manual permanent magnetic actuator, it is used in the control unit and electricity, under the condition of the damage, the emergency brake manually points on the circuit breaker break-brake operations. Emergency brake manually points must be purely mechanical operation, cannot use electrical and electronic components to operate. Emergency brake manually points used to disconnect the rated current, short circuit conditions generally don't use this feature.

At present, some factory is equipped with permanent magnetic actuator for manual switching function. Actually, manual switching function of permanent magnetic actuator is not practical, one is the operator have a safety risk, the second is the permanent magnetic actuator manually closing speed slower, or more likely, the third is in the case of double line power supply, closed loop, the transmission may occur, threat power maintenance personnel safety, and even lead to major injuries. Ban equipped with permanent magnetic actuator, so some users definitely require manual switching functions, such as coal mining system.

3, we also developed the emergency switch controller, used for emergency control of permanent magnet circuit breaker: after the permanent magnet switch installed on the electric pole there is no power supply (including backup power supply), can this temporary control switch controller; When permanent magnet switch matching control part failure, also can use this controller emergency control switch. This device has the advantages of compact structure, easy to carry, permanent magnet switch in the on line during the inspection, and in the workshop of the permanent magnet switch is very suitable for maintenance.

 

The second chapter, the basic working principle of permanent magnetic actuator

A, classification,

According to different standards, divided into different types, permanent magnetic actuator are mainly monostable and bistable, single-coil and double coil, round and square, no obvious advantages and disadvantages between them, each have their advantages. A brief introduction of the following orders the difference between steady state and bistable permanent magnet mechanism.

Refers to the so-called bistable permanent magnet mechanism, is in the closing end, break-brake end adopts permanent magnet, points, closing action is respectively by two field coil driver to complete the moving core; So-called monostable permanent magnetic mechanism, refers to the permanent magnets at closing, in the spring brake is use to maintain, feed motion through the switching excitation coil electricity drive to complete the moving core, at the same time in the process of switching to keep break-brake spring energy storage, break-brake movement is by the release of break-brake spring to complete.

Monostable permanent magnetic actuator and bistable no advantages and disadvantages of distinction, have their own advantages.

bistable

Advantage: under the same conditions, the bistable switching current peak value smaller, permanent magnetic actuator for control section, the smaller the current, means that the control is simple, reliable, the smaller the risk of damage to the controller. In addition, the switching current smaller, discharge capacitance need not too big, generally with a 100 v / 100 micro method of electrolytic capacitor can be achieved reclosing of circuit breaker operation.

Disadvantage: based on the design principle of bistable bistable of permanent magnetic actuator is apart from the average speed of slower than fully open.

monostable

Advantage: as the monostable brake action of permanent magnetic actuator are completed by break-brake spring, so its just cent of break-brake peace split brake speed is better than that of bistable permanent magnet mechanism, and the characteristic curve of break-brake reaction of circuit breaker can match.

Disadvantage: as the monostable permanent magnetic mechanism when switching to keep break-brake spring energy storage at the same time, so the same condition, the switching current peak than bistable permanent magnet mechanism.

 

Second, the basic principle

The basic working principle of permanent magnetic actuator can be summed up three words: permanent magnet, electromagnetic drive, electronic control.

Permanent magnet keep: switching state is by permanent magnets to keep, to overcome the contact spring reaction;

Driver: electric field coil to produce electromagnetic energy to drive the core movement, complete points feed motion;

Electronic control: the permanent magnetic actuator control system adopts electronic devices, including power electronic switch (IGBT, MOSFET, thyristor) chip, integrated circuit board, CPU, etc. 

permanent magnetic actuator 1

Member Information

GUANGZHOU GUONENG AUTOMATIC CONTROL TECHNOLOGY CO.,LTD
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:13928875776
Contact:Posco wen (manager)
Last Online:21 Nov, 2021