Digital ultrasonic flaw detector BSM320

Digital ultrasonic flaw detector BSM320
Model:BSM320
Brand:arctic stars
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Other Electronic Instrument
Label:Ultrasound detector , Testing machine , Flaw detector
Price: US $4396 / pc
Min. Order:1 pc
Inquire Now
点击这里给我发消息

Product Description

Performance Features
Automated gain、Peak Hold and Peak Memory;
Automated display precise flaw location(Depth d、level p、distance s、amplitude、sz dB、ф);
Ten independence setup, any criterion can be input freely, we can work in the scene without test block;
Big memory of 300 A graph and 30000 thickness value.
Gate and DAC alarm;Acoustic-Optical alarm;
RS232 port,communication with pc is easy;
The embeded software can be online updated;
Li battery, continue working time up to 7 hours;
Other assistant function;
Display freeze;
Automated echo degree;
Angles and K-value;
Lock and unlock function of system parameters;
Dormancy and screen savers;
Electronic clock calendar ;
Two gates setting and alarm indication;
High-speed capture and very low noise;
DAC、AVG; Solid metal housing (IP65);
Provides high contrast viewing of the waveform from bright, direct sunlight to completae darkness and easy to read from all angles;
Powerful pc software and reports can be export to excel;
Technical Parameters
Designation
Technical Data

Range of scanning (mm)
Range of scanning (mm):2.5~60000(Steel Longitudinal wave)

Steps: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200, 250, 300, 350, 400, 450,500,600,700,800,900,1000,2000,3000,4000,5000,6000

Adjusting step: 0.1mm(2.5 mm~99.9mm),1mm(100mm~10000mm)

D-delay (ms)
D-delay (ms):-20~+3400

Steps: -20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600,

700,800,900,1000,1500,2000,2500,3000,3400.

Adjusting steps: 0.1(-20ms~999.9ms),1(1000ms~3400ms)

P-delay (ms)
P-delay:0.0~99.99

Adjusting steps: 0.01

MTLVEL(m/s)
MTLVEL:1000~9999

7 fixed levels: 2260,2730,3080,3230,4700,5920,6300

Adjusting steps:1

Working mode
Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission(transmission probe)

FrequencyRange (MHz)
0.4–20

Gain adjustment (dB)
0~110

Adjusting step: 0.0,0.2,0.5,1,2,6,12

Reject
0%~80% of screen height, step: 1%

Vertical linear error
Vertical linear error is not more than 3%

Horizontal linear error
Not more than 0.2% in the scanning range

Sensitivity Leavings
≥62 dB

Dynamic range
≥32dB

Alarm
Three modes, i.e. forbidden wave, loss wave and auto

Monitoring door
2, expressed by bold transverse line, whose start, width and height are adjustable.

Adjusting range of start (mm): horizontal pixel 0~208, the displayed value is relative with the scanning range.

Step: value in mm corresponding to a pixel (relative with the scanning range)

Adjusting range of width (mm): horizontal pixel 4~212, the displayed value is relative with the scanning range.

Step: value in mm corresponding to a pixel (relative with the scanning range)

Adjusting range of height: 2%~90% of vertical graduation

Step graduation: 1%

Display




Display: high-brightness lattice



A-Scan display area
Full screen or local

A-Scan display freezing and de-freezingA-Scan filling

Data save
300 A-Scan images (including setting of instrument)

30000 values of thickness (300 sets)

Standard communication interface with PC
RS232

Measuring unit
mm/inch

Battery
Li battery 4×3.6V4800mAh

Power adaptor
Input 100V~240V/50Hz~60Hz

Output 9V~12VDC/1.5A

Working temperature
-20℃~70℃

Working humidity
20%~90%

Port type
BNC

Overall dimension (mm)
240×180×50

Weight (kg)
1.8




List of standard configurations
Designation
Quantity

Main unit
1

1.5A/9V power adaptor
1

probe connecting cable
2

Carrying case
1

Instruction manual
1

Straight probe
F20 2.5MHz (One)

Angle probe
2.5MHz10×10K2 (One)


Digital ultrasonic flaw detector BSM320 1

Member Information

Beijing arctic stars technology Co., LTD
Country/Region:Beijing - China
Business Nature:Manufacturer
Phone:13522762465
Contact:FuXingSen (The manager)
Last Online:13 Jan, 2014