Characteristics and specifications
Measure PK,QP and AV, range from: 9kHz-150 kHz:20dBμV-130 dBμV;
150 kHz-30MHz:10 dBμV-90 dBμV
Band width: 9 kHz-150KHz: 200Hz;
150kHz-30MHz: 9kHz;
Frequence sweeping step interval: 9kHz-150kHz:100Hz、200Hz、400Hz selectable
150kHz-30MHz:5kHz、10kHz、20kHz selectable
Sweeping time selectable;
Sweeping range selectable, freely zoom the frequency sweeping diagram;
Accuracy:3 dB;
Input resistance: 50Ω, Maximum input signal: 2V, Protected at 5V;
Use 50Ω/50μH+5Ω single phase simulative network according to CISPR standard;
Limit value freely set, the built-in limit value in instrument according to GB17743、FCC、EN55015、EN55022 can be used directly, for the convenience of customer;
Running under Windows98/Windows2000 and both Chinese version and English version available.