Model: | HHEX01 |
---|---|
Brand: | HongCe |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Test Bench |
Label: | helium leak test , leak detection , vacuum detection |
Price: |
-
|
Min. Order: | 1 pc |
Last Online:01 Aug, 2019 |
Vacuum Chamber Helium Leak Test Equipment for Large Heat Exchanger
Basic Techinal Parameters:
Test Workpiece |
Heat Exchanger |
Vacuum Chamber |
1 |
Vacuum Chamber Dimension |
According to the actual workpiece dimension, no more than 1300L |
Number of Workpiece per Chamber |
1 |
Workpiece Connection Method |
Fixture positioning, joint sealing |
Leakage Rate |
1g/a |
Test Cycle |
6min/pc (Time from chamber door closed to opened) |
Gas for Gross Leakage Detection |
Nitrogen |
Pressure for Gross Leakage Detection |
4.0Mpa (Downwards adjustable) |
Gas for Fine Leakage Detection |
Helium (>99.99%) |
Pressure for Fine Leakage Detection |
4.0Mpa (Downwards adjustable) |
Connection between Workpiece and Vacuum Chamber |
The operator plugs one end of the workpiece with a special plug, and seals the other end of the workpiece with a special connector. After the workpiece is transferred into the vacuum chamber, the special sealed male connector of the workpiece is connected to the quick female connector in the vacuum chamber. |
Helium Recovery |
Automatic recycling system, helium recovery rate≥98% |
Basic Working Principle
According to the basic principles of helium leak detection, helium as a tracer gas, the workpiece will be filled with helium in the vacuum chamber, and then through a helium leak detector leak can quickly and accurately determine the accuracy of the workpiece’s leakage.
Work Process Chart